When speaking with your Titan representative, please indicate whether the item is still under warranty. Shipping cost to and from a Titan Logix service facility is the responsibility of the customer unless the product is under warranty. If the product is under warranty, the freight cost to Titan is incurred by the customer.
There are no serviceable parts in this device. A violated warranty seal will render any warranty null and void. ISCLAIMER The information in this document is subject to change without notice. Titan Logix Corp. makes no representations or warranties with respect to the contents hereof. ROPRIETARY NFORMATION The Information disclosed herein contains proprietary rights of Titan Logix Corp.
Keep all passwords documented and secure. Password must use a combination of letters, numbers, and symbols and be at least 8 characters long with no spaces or the special characters: < > & ’ TPM 053 Version 1.0, May 30, 2017 Page | 4...
Gateway Utility Description ........................22 Gateway Status Screen ........................22 Connecting to the Network ......................... 22 Gateway Configuration Screen ......................23 Changing the Wi-Fi Password ......................25 Configuration and Communication Test Procedure ................28 TPM 053 Version 1.0, May 30, 2017 Page | 5...
Page 8
Gateway Module ..........................41 System Wiring ............................. 41 Maintenance ............................41 REFERENCE DRAWINGS ..........................42 Tank Truck Wiring Schematic ........................43 Trailer Wiring Schematic ......................... 45 Mounting Template Drilling Guide ......................47 TPM 053 Version 1.0, May 30, 2017 Page | 6...
Figure 4 – Interconnect Cable Module Mounting Bolts The module mounting bolts are supplied in order to secure the Gateway module to the mounting bracket. Figure 5 – Module Mounting Bolts TPM 053 Version 1.0, May 30, 2017 Page | 8...
These alarm states control four internal relays for alarm annunciation, high level shutdown and low level prevention. Figure 8 – Finch II Display TPM 053 Version 1.0, May 30, 2017 Page | 9...
*External Ethernet adapter is not supported for Windows 10 Replacement Parts Description Titan Part Number Gateway Mounting Bracket 1025-1042 Gateway Module, Model CTX-TDS-100 Gateway Interconnect Cable 1003-0024 Mounting Bolts 1017-2112 TPM 053 Version 1.0, May 30, 2017 Page | 12...
TPM 001 and Finch II product manual, TPM 010. For your convenience, we have provided a checklist so that you can keep track of where you are in the installation process. TPM 053 Version 1.0, May 30, 2017 Page | 13...
Page 16
4. Air Pressure Switch to Junction Box Connected (Trailer) 5. Electrical Power to Junction Box Connected 6. Visual Inspection Performed Confirmation Checklist Checked Steps 1. Operation of the Gateway Confirmed TPM 053 Version 1.0, May 30, 2017 Page | 14...
Maximum view of sky for best radio reception (module only) • Minimize electrical cable length where possible • Locate for ease of installation and repair • Protected from damage by road debris, trees, stepping or climbing, etc. TPM 053 Version 1.0, May 30, 2017 Page | 16...
• ensure the area is free of debris • ensure electrical connections are secure • ensure all components are securely fastened • ensure there is a clear view of sky TPM 053 Version 1.0, May 30, 2017 Page | 17...
Refer to the electrical options above for truck or trailer installation. Connect the Finch Display to the Junction Box Connect the Air Pressure Switch to the Junction Box (Trailer Installations) Connect Electrical Power to Junction Box Perform a Visual Inspection TPM 053 Version 1.0, May 30, 2017 Page | 18...
Once powered up, the boot cycle for the module can take up to 2 minutes. If the Gateway module is not operating as per the above condition, refer to the Troubleshooting section of this manual or contact your Titan representative. TPM 053 Version 1.0, May 30, 2017 Page | 19...
GATEWAY OPERATION The Gateway System does not have any operational controls. Operation is automatic when power is applied. Indication of operation is by observation of the status light on the module. TPM 053 Version 1.0, May 30, 2017 Page | 20...
Each Gateway system ships with the WI-FI password and SSID pre-installed at the factory. The SSID is located on the identification label on the bottom of the Gateway module: Figure 13 – Gateway Identification Label TPM 053 Version 1.0, May 30, 2017 Page | 21...
. If the correct network does not appear in the list, click on the refresh button Enter your supplied password and click Connect ❖ TPM 053 Version 1.0, May 30, 2017 Page | 22...
Configuration Utility manual TPM 054. Gateway Configuration Screen This screen displays the Gateway settings. It displays information on: • Remote server • Network servers • DNS servers • Finch II communication • TPM 053 Version 1.0, May 30, 2017 Page | 23...
Page 26
3. Select the correct file and click Open 4. Record the settings in a text file or capture a screenshot with the configuration settings; save in a secure place and use for reference when needed TPM 053 Version 1.0, May 30, 2017 Page | 24...
Keep the passwords in a secure place and use for reference when needed. Establish a Wi-Fi connection to the Gateway, then click on the Wi-Fi option under the Configuration dropdown. ❖ TPM 053 Version 1.0, May 30, 2017 Page | 25...
Page 28
1. Once the password has been reset, restart the Gateway device or cycle the power 2. Click on RESTART>GATEWAY DEVICE 3. Choose Yes/No or cycle the power After restarting the Gateway device, the user must perform the network connection steps listed previously. TPM 053 Version 1.0, May 30, 2017 Page | 26...
Page 29
SOFTWARE Gateway Installation and Operation Manual TPM 053 Version 1.0, May 30, 2017 Page | 27...
Go to the Gateway Status page 4. Check the a) PPP Link Status, checked Cellular b) Signal Strength, good Status 5. Check the ❖ a) Communication Established Remote Server Status TPM 053 Version 1.0, May 30, 2017 Page | 28...
Whenever there is an internet connection, the Utility will search for, and auto-update the program. The program will prompt if you want to do the update. Once the program is launched, you will see the following status as the utility updates: TPM 053 Version 1.0, May 30, 2017 Page | 29...
Keep all passwords documented and secure • Password must be at least 8 characters. Use a combination of letters, numbers and symbols. Do not use spaces or these special characters: < > & ’ TPM 053 Version 1.0, May 30, 2017 Page | 30...
4. Cellular connection PPP Link Status, checked Signal Strength, good 5. Remote server connection Confirm: Communication Established, checked Confirm the following: 6. GPS data Communication Status, checked GPS Fix Status, checked TPM 053 Version 1.0, May 30, 2017 Page | 32...
Internal junction box wiring • Gateway to Finch II wiring 3. Contact Titan Status light is ½ second on, ½ Gateway is operating Continue with the diagnostics below second off TPM 053 Version 1.0, May 30, 2017 Page | 34...
Perform each of the diagnostic steps below before performing any communications troubleshooting to determine the status of the Gateway system. Issue resolution may require contacting your Titan representative. ❖ TPM 053 Version 1.0, May 30, 2017 Page | 35...
Page 38
Stationary Rate setting Gateway Status screen: Confirm the following: a) Communication Status, checked 7. GPS data b) GPS Fix Status, checked c) GPS Longitude and Latitude, current location TPM 053 Version 1.0, May 30, 2017 Page | 36...
1. Ensure there is power to the system 2. Ensure the Gateway is within transmission range 3. Ensure the SSID is correct 4. Ensure the Wi-Fi adapter is turned on TPM 053 Version 1.0, May 30, 2017 Page | 37...
Page 40
PPP link is not detected 1. Check the cellular signal strength 2. Check the APN Server settings 3. Cycle the power to the Gateway 4. Observe the PPP link after 2 minutes TPM 053 Version 1.0, May 30, 2017 Page | 38...
Page 41
1. Check the Remote Server and DNS settings 2. Check PPP link status is checked 3. Cycle the power to the Gateway 4. Observe the PPP link and remoter server communication after 2 minutes TPM 053 Version 1.0, May 30, 2017 Page | 39...
Page 42
Gateway date and time are incorrect Check the Network Servers, SNTP Server setting Condition Resolution Gateway is not sending data at the expected rate Check the GPS and Sensor Rate settings in the Gateway Configuration TPM 053 Version 1.0, May 30, 2017 Page | 40...
Gateway module to the junction box is secure • cables are not damaged or frayed • the Gateway status light is displaying correctly • the module, cables, and peripheral equipment are free of any obstructions or debris TPM 053 Version 1.0, May 30, 2017 Page | 41...
Figure 14 – Truck Wiring Schematic Gateway Interconnect Cable Connection Details RD – Power BLK – Ground GRN – RS232 from the Gateway WHT – RS232 to the Gateway TPM 053 Version 1.0, May 30, 2017 Page | 43...
Page 46
Vehicle Finch II Connection Interconnect Terminals Switch Power from Terminals Cable Wires Terminals Switched Accessory Power GND IN PWR IN 7 – Optional, reserved for LoadMaxx Chassis Ground Accessory Power TPM 053 Version 1.0, May 30, 2017 Page | 44...
Drawing 1001135v1.0 is not to scale and is provided solely for the purpose of showing the bolthole pattern required in the mounting of the Gateway bracket. Figure 16 – Mounting Template TPM 053 Version 1.0, May 30, 2017 Page | 47...
Page 50
Manufactured by: Manufactured in Canada Head Office 4130-93 Street Edmonton, Alberta Canada T6E 5P5 P 780.462.4085 F 780.450.8369 Toll Free 1.877.462.4085 | TSX-V: TLA Sales Department: Email us at sales@titanlogix.com | Service Department: Email us at service@titanlogix.com Find us online at www.titanlogix.com...
Need help?
Do you have a question about the TPM 053 and is the answer not in the manual?
Questions and answers