Item
5. Sensitivity
1) Test Channel
check
Channel: 1
Test Signaling
Mode: Analog
Signaling: 1
SSG output
Wide: –117dBm (0.32µV)
(MOD: 1kHz/±3kHz)
Narrow: –117dBm (0.32µV)
(MOD: 1kHz/±1.5kHz)
Common Section
Item
1. Setting
1) DC voltage: 7.5V
2) SSG standard modulation
[Wide] MOD: 1kHz, DEV: 3kHz
[Narrow] MOD: 1kHz, DEV: 1.5kHz
2. Counter-
1) Adj item: [Counterclockwise Volume]
clockwise
Volume
3. Clockwise
1) Adj item: [Clockwise Volume]
Volume
4. Receive
1) Adj item: [Receive Assist]
Assist
2) Adj item: [Low], [Low'], [Center], [High'],
[High]
Press [Apply All] button to store the adjust-
ment value.
Transmit
1) Adj item: [Transmit Assist]
Assist
2) Adj item: [Low], [Low'], [Center], [High'],
[High]
PTT: Press [Transmit] button.
Press [Apply All] button to store the adjust-
ment value.
ADJUSTMENT
Condition
equipment
SSG
AF VM
Oscilloscope
Distortion
meter
8
Dummy
load
Condition
equipment
Measurement
Test-
Unit
Terminal
Unit
ANT
Universal
connector
Measurement
Test-
Unit
Terminal
Unit
NX-300(S)
Adjustment
Specifi cations /
Parts
Method
Check
12dB SINAD or
more
Adjustment
Specifi cations /
Parts
Method
Turn the volume
This item is needed
knob counterclock-
when the variable
wise fully.
resistor (R31-0666-
Press [Apply] button
05) is replaced.
to store the adjust-
ment value.
Turn the volume
knob clockwise fully.
Press [Apply] button
to store the adjust-
ment value.
[ ],[ ] [V] indicator on the
2.5V±0.1V
PC window shows
VCO lock voltage.
Press [Apply All]
Change the adjust-
button to store the
ment value to get
adjustment value
VCO lock voltage
after all adjustment
within the limit of the
points have been
specifi ed voltage.
adjusted.
Note:
Confi rm the VCO
lock voltage approx-
imately 3 seconds
after the adjustment
value is changed.
Remarks
Remarks