TE100 with T4000 Quick Reference
Important: This document contains condensed information to be
used by experienced operators as a quick reference. The
operator should have performed a thorough review of the Model
TE100 Electronic Small Bagging Scale Operation and
Maintenance Manual prior to using this quick reference guide.
Using the Keypad
To the right of the LCD screen is a keypad. It has an Enter key in the
Enter, surrounded by four directional arrows. These buttons, along with
the four function keys below the LCD screen, are used to navigate the
menu system and make adjustments to settings.
Enter
Function
keys
When entering numeric values, the operator will use the left and right
arrow keys to move from position to position, and the up and down
arrow keys to increase or decrease the number in a specific position.
Use arrow
keys adjust
Once the desired number is displayed, the operator will press the Enter
key to save the setting.
Setting Dribble, Cutoff, and Target Set points
1.
Press the function key directly below where TGT is displayed
on the summary screen.
2.
Use the arrow keys to enter the desired Target weight.
3.
Press the Enter key to save the entry and return to the
summary screen.
4.
Press the function key directly below where DRIB is
displayed on the summary screen.
5.
Use the arrow keys to enter the desired Dribble weight.
6.
Press the Enter key to save the entry and return to the
summary screen.
Revision 002
Left
Down
7.
Press the function key directly below where CUTOFF is
displayed on the summary screen.
8.
Use the arrow keys to enter the desired Cutoff weight.
9.
Press the Enter key to save the entry and return to the
summary screen.
Setting Target Min/Max
1.
Press the function key directly below where MENUS is
displayed on the summary screen.
Up
Right
2.
Use the down arrow button to scroll down to place cursor in
front of the Target Min/Max menu line.
3.
Press the Enter key.
4.
The cursor should be in front of the Target Max menu line. If
it is not, use the up/down arrow buttons to scroll to the Target
Max menu line.
5.
Press the Enter button.
6.
Enter in the desired maximum allowable fill weight.
7.
Press the Enter key to save the entry and return to the Target
Min/Max menu.
8.
Use the down arrow button to scroll down and place the
cursor in front of the Target Min menu line.
9.
Press the Enter key.
10. Enter in the desired minimum allowable fill weight.
11. Press the Enter key to save the entry and return to the Target
Min/Max menu.
12. Press the function key below the word EXIT twice to return to
the summary screen.
13. The fill speeds are now set.
1
2205 Jothi Avenue
Parsons, Kansas 67357
Toll Free:
888.882.9567
Visit:
www.magnumsystems.com
Guide

Advertisement

loading

Summary of Contents for Magnum TE100

  • Page 1 The displayed on the summary screen. operator should have performed a thorough review of the Model TE100 Electronic Small Bagging Scale Operation and Maintenance Manual prior to using this quick reference guide. Using the Keypad To the right of the LCD screen is a keypad.
  • Page 2 The the calibration was successful. procedure also assumes that the TE100 is turned on and has An Error number appears if the calibration was not been allowed to warm up for a minimum of fifteen (15) successful.

This manual is also suitable for:

T4000