  • Page 1 User Manual  BL 303 Models:  BL 602  BL 2002  BL 3001  BL 6001  BL 30K1...
  • Page 2: Table Of Contents

    Index GLASS PROTECTION ERRORE. IL SEGNALIBRO NON È DEFINITO. INSTALLATION KEYBOARD START DATE AND TIME SETTINGS USER CALIBRATION ALIBRATION PROCEDURE UNIT SETTING NIT SELECTION EFAULT UNIT SETTINGS ZERO TARE MEASURE COUNTER FUNCTION RS-232 SETTINGS TEM SETTINGS BATTERY TROUBLESHOOTING: DATASHEETS DISPOSAL OF ELECTRONIC DEVICES...
  • Page 3: Glass Protection

    Glass protection BL 303...
  • Page 4 BL 602...
  • Page 5 BL 2002 – BL 3001 – BL 6001...
  • Page 6: Installation

    Installation  Place the balance and, using the adjustable feet and the bubble on the back, adjust the inclination. The scale MUST be leveled.  Protect the balance from drafts, so do not install near windows or air conditioners;  Protect the balance from vibrations;...
  • Page 7: Start

    Start Place the scale, and using the bubble on the backside for level It. Press On / Off to turn on the scale. Following a countdown, marked also by the beep, you will see the software version, the capacity of the scale, and then you enter the measurement mode. Wait at least 30 minutes to warm up before the first use.
  • Page 8: Unit Setting

    Allowed calibration weights [g] for each Examples: model BL 303 100 – 200 - 300 If the display shows the blinking value: 2000, BL 602 200 – 400 - 600 on the plate a certificated sample mass of 2000g. BL 2002 1000 –...
  • Page 9: Counter Function

    Counter Function Set one of these units: PCS, % or ‰, and press button. Display shows “S – 5”: 5 is the number of required pieces for the sampling, or the % to associate with the reference sample. With the button, select the desired value between these: 5, 10,50, 100, 500 e 1000.
  • Page 10: Battery

    Check if the plate interferes with the Sample is heavier than the capacity “Over” safety screws present above and supported. below the instrument, in correspondence of the load cell. Datasheets Models BL 303 BL 602 BL 2002 BL 3001 BL 6001 BL 30K1 27000513 27000323 27000313...
  • Page 11: Disposal Of Electronic Devices

    Disposal of electronic devices The electrical and electronic equipment marked with this symbol cannot be disposed of in public landfills. According to the UE Directive 2002/96/EC, the European users of electrical and electronic equipment can return it to the dealer or manufacturer upon purchase of a new one. The illegal disposal of electrical and electronic equipment is punished with an administrative fine.