Page 1
User Manual XS BW 3000 = No ingress of dust; complete protection against contact (dust tight) IP 67 = Ingress of water in harmful quantity shall not be possible when the enclosure is immersed in water under defined conditions of pressure and time (up to 1 m of submersion).
Index Installation ................................. 3 Keyboard and definition of keys ........................3 Start ................................... 4 User calibration (only for no OIML products) ....................4 Calibration procedure ............................ 4 Unit Setting ................................ 4 Unit selection ..............................4 Zero ..................................4 Tare ..................................4 Measure ................................
Installation • Place the balance and, using the adjustable feet and the bubble on the front, adjust the inclination. The scale must be leveled; • Do not install near windows or air conditioners; • Protect the balance from vibrations; • Working temperature: 10°C –...
Start Place the scale, and ,using the bubble on the frontside, level It. Press to turn on the scale. Following a countdown, marked also by the beep, you will see the software version, the capacity of the scale, and then you enter the measurement mode. Wait at least 15 minutes to warm up before the first use.
Measure Place the sample on the plate. Wait that the stability indicator lights before taking the measurement. Function Counter function Select weighting unit PCS. Now hold key for 3 second: display shows SP=5. Press key to select the reference number (5, 10, 20, 50, 100, 200, 500), place the same quantity of samples on the plate and press key.
Page 6
Set higher limit Display How to change value when is Set - Hi 3,000 flashing Confirm Increase the value Set lower limit Display Move to next digit Set - Lo 0,000 Confirm High limit limit Display Set alarm rules Only when the weight is Set - Li L in - Lo less than the lower limit...
Function settings To enter in the function settings menu, , keep pressed for 3 seconds (If check-weighing function is active, software doesn’t allow the operator to enter in the function menu To deactivate, in weighing mode press Display shows Ck – OFF.) F = Fast Set the speed Speed -...
Battery The scale mounts a rechargeable battery. To recharge the battery use the power supply placed inside the compartment at the bottom of the scale. In order to open the compartment it is necessary to remove the 4 screws. Is not recommended to use the balance with the power supply connected. With the bottom compartment opened, IP67 Is no guaranteed.
Need help?
Do you have a question about the XS BW 3000 and is the answer not in the manual?
Questions and answers