Ipm Continuity Check; 4-Way Valve - KOREL M2OC-18HFN8-Q Service Manual

Europe maket super dc inverter multi type, r32 dc multi outdoor units
Table of Contents

Advertisement

3. IPM continuity check

Turn off the power, let the large capacity electrolytic capacitors discharge completely, and dismount the IPM. Use a digital
tester to measure the resistance between P and UVWN; UVW and N.
Digital tester
(+)Red
(-)Black
P

4.4-way valve

1. Power on, use a digital tester to measure the voltage, when the unit operates in cooling, it is 0V. When the
unit operates in heating, it is about 230VAC.
If the value of the voltage is not in the range, the PCB must have problems and need to be replaced.
2 Turn off the power, use a digital tester to measure the resistance. The value should be 1.8~2.5 KΩ.
Normal resistance value
N
U
(Several MΩ)
V
W
Digital tester
(+)Red
(-)Black
U
V
N
W
(+)Red
57
Normal resistance value
(Several MΩ)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents