& Current-to-Pressure (I/P) Transmitters Introduction & IPX This users’ manual for Moore Industries’ IPH The rugged IPH and IPX Current-to-Pressure (I/P) Current-to-Pressure Transmitters contains all Transmitters are designed specifically for extended of the information that is needed to calibrate, install, duty in harsh field environments.
& Current-to-Pressure (I/P) Transmitters Specifications Accuracy: <±0.25% of span Performance Voltage Drop: Performance Operating & Storage Ambient including the combined effect (Continued) 5V, maximum Range: Conditions Air Consumption of linearity, hysteresis and -40°C to +85°C repeatability (between (Dead-ended): (-40°F to +185°F) 0 and 3psig output, error will At 3-15psig output 20psig Ambient Temperature...
& Current-to-Pressure (I/P) Transmitters Calibration Note: Always use clean, dry, instrument air when Every IPH and IPX is fully tested and calibrated at the calibrating or operating the IPH or IPX factory prior to shipment. However, before installation, your IPH or IPX should be bench-checked to verify All pneumatic lines used in calibration and operation...
Page 8
& Current-to-Pressure (I/P) Transmitters Figure 3. IPH Calibration Setup ADJUSTABLE CURRENT SOURCE MULTIMETER REGULATED PNEUMATIC INSTRUMENT TEST LOAD AIR SUPPLY PRESSURE GAUGE #1 PRESSURE GAUGE #2 (ACCURACY ±2%) (ACCURACY ±0.1%) OUTPUT INPUT PORT PORT Figure 4. IPX Calibration Setup INPUT OUTPUT PRESSURE GAUGE #1 PRESSURE GAUGE #2...
Page 9
& Current-to-Pressure (I/P) Transmitters 10. Monitor reading of pressure gauge #2 (output), Calibrating the IPH or IPX and adjust span potentiometer so that reading is This calibration procedure consists of a basic check at 0% of span for your unit (i.e. 3 psi for a 3-15 psi and adjustment of unit zero and span, based on the unit).
& Current-to-Pressure (I/P) Transmitters Installation Use shielded, twisted-pair wiring for low-level input. Ground the shielding wire as close as possible to the The installation of the IPH or IPX is carried out in installed unit. three phases: the physical mounting of the unit, the electrical connections phase, and the pneumatic connections phase.
& Current-to-Pressure (I/P) Transmitters Phase Three: Indoor natural gas operations are typically monitored to maintain safety conformance outside the lower Pneumatic Connections and upper explosion limits (LEL and UEL). To add To complete the final phase of installation, connect the a natural gas operated transmitter in these cases, supply line to the ¼-inch NPT female port labeled “IN”.
& Current-to-Pressure (I/P) Transmitters Hazardous Location Special Conditions of Use Applications The following instructions must be adhered to when the Model IPX is used in hazardous locations and potentially explosive atmospheres. This section contains important information regarding installation of IPX in hazardous locations.
& Current-to-Pressure (I/P) Transmitters European Union Installations be protected from impact. (ATEX 2014/34/EU Directive) Intrinsically Safe Applications Certificate No.: ANZEx 09.3000X Standards: Intrinsically Safe Applications - Zone 0 AS/NZS 60079.0:2005 Explosive atmospheres - II 1 G Ex ia IIC T4 Ga Equipment - General requirements The enclosure is manufactured from 6063-T5 AS/NZS 60079.11:2006 Explosive atmospheres -...
& Current-to-Pressure (I/P) Transmitters Troubleshooting the recovery of the unit, by allowing any accumulated liquid to drain out more effectively. To remove the the IPH & IPX module follow these steps: If a problem is suspected with the IPH or IPX , review 1.
& Current-to-Pressure (I/P) Transmitters Customer Service Figure 8. Removing Module from Housing Moore Industries is recognized as the industry leader in delivering top quality to its customers in products and services. We perform a battery of stringent quality assurance checks on every unit we ship. If any Moore Industries product fails to perform up to rated specifications, call us for help.
RETURN PROCEDURES To return equipment to Moore Industries for repair, follow these four steps: 1. Call Moore Industries and request a Returned Material Authorization (RMA) number. Warranty Repair – If you are unsure if your unit is still under warranty, we can use the unit’s serial number to verify the warranty status for you over the phone.
Need help?
Do you have a question about the IPH2 and is the answer not in the manual?
Questions and answers