Dynabrade 10685 Machine Parts & Operating Instructions

Filter-regulator-lubricator; 1/2" npt inlet/outlet ports

Advertisement

Quick Links

Filter-Regulator-Lubricator
1/2" NPT Inlet /Outlet Ports
Machine Parts & Operating Instructions – Save This Document and Educate All Personnel
WARNING
To reduce risk of
injury, everyone using,
installing, repairing,
maintaining, changing
accessories on, a
working near this tool MUST read
and understand these instructions
before performing any such task.
DO NOT DISCARD – GIVE TO USER.
FILTER
3
1
2
4
Index Key
Item
Part No.
1
10645
Filter Element (5 Micron)
2
10684
3
10692
4
10693
Bowl Assembly
5
10640
Valve Assembly
6
10641
Diaphragm Assembly
7
10642
Valve Guide Assembly
8
10698
Lubrication Plug Assembly
9
10658
Damper Retainer Assembly
10
10668
Bowl Assembly
11
10659
Damper Assembly
12
10656
Slight Dome Assembly
13
10665
Mounting Bracket (2)
14
10667
10697
Dual Pressure Guage (Not Shown)
Always follow the safety instructions provided in this manual. They are intended to prevent a hazardous situation
and / or equipment damage. Refer to Dynabrade's Pneumatic tool safety & operating guidelines. For additional
safety, be sure to observe ISO 4414 - General rules and safety requirements for systems and their components.
Model No.
10685
10694
10687
10688
10689
10690
REGULATOR
13
14
5
6
Description
Baffle
Bowl O-Ring
Seal
Description
Filter
Regulator
Lubricator
Filter-Regulator
Regulator-Lubricator
Filter-Regulator-Lubricator
7
Inlet/Outlet
Max.
Port
Air Pressure
150 PSIG
1/2" NPT
(10.3 Bars)
3/8" Reducer Bushings
The enclosed bushings (2) are supplied to
reduce the 1/2" NPT openings of the enclosed
Filter-Regulator-Lubricator to 3/8" NPT.
(Use only if required)
LUBRICATOR
12
8
11
9
3
10
Max.
Max. Air
Air Flow
Temperature
106 SCFM
150˚ F
(3,000 LPM)
(65˚ C)
IMPORTANT
Do Not Overtighten
the Bushings!
The bushings will not
engage entirely into
the 1/2" NPT opening
after tightening.
Refer to recommended
tightening torque chart
.475"
on page 6.
(12 mm)
PD16.19
July, 2016

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 10685 and is the answer not in the manual?

Questions and answers

Summary of Contents for Dynabrade 10685

  • Page 1 Always follow the safety instructions provided in this manual. They are intended to prevent a hazardous situation WARNING and / or equipment damage. Refer to Dynabrade's Pneumatic tool safety & operating guidelines. For additional safety, be sure to observe ISO 4414 - General rules and safety requirements for systems and their components.
  • Page 2: Installation Instructions

    2. Remove the fill cap plug by turning it counterclockwise. LUBRICATOR SETTING 3. Fill the bowl to the fill line with air tool oil. Use Dynabrade Air Lube 95842 or equivalent air tool oil (10W/NR). 1 DROP PER MINUTE 4. Replace the fill plug by turning in clockwise.
  • Page 3: Filter

    218 PSIG (15 Bars) Max Operating Pressure: 150 PSIG (10.3 Bars) Oil Capacity 4.6 oz. (135 cm Recommended Lubricant Dynabrade Air Lube (10W/NR) Ambient and Fluid Temperature 23 to 140˚F (-5 to 60˚C) [with no freezing] Bowl Material Zinc Weight...
  • Page 4: Safety Instructions

    Exemption from Liability 1. Dynabrade, Inc. is exempted from liability for any damages caused by operations not contained in the catalogs and/or instruction manuals, and operations outside of the specification range. 2. Dynabrade, Inc. is exempted from liability for any loss or damage whatsoever caused by...
  • Page 5: Lubricator

    Contact Dynabrade, Inc. if air will not be consumed in the system for a long period of time, or if the outlet side will be used with a sealed circuit and a balanced circuit, as this may cause the set pressure of the outside to fluctuate.
  • Page 6: Filter-Regulator

    F.R.L. Unit Precautions 2 Be sure to read before handling Mounting Piping Caution Warning 1. To avoid reversed connections of the air inlet/outlet, make 1. To screw piping materials into components, tighten with a recommended tightening torque while holding the female thread connections after confirming the “IN/OUT”...
  • Page 7: Air Supply

    F.R.L. Unit Precautions 3 Be sure to read before handling Piping Maintenance Caution Warning Lubricator 1. When disassembly or installation is required during the maintenance, repair, or replacement of a device, be sure to follow Try to avoid riser piping and branch lines as much as possible on the instructions provided in the instruction manual or safety the outlet side, otherwise proper lubrication will be compromised.
  • Page 8: Filter-Regulator-Lubricator

    — 0.14 1,274 0.14 1,699 0.28 2,124 0.34 ® DYNABRADE Visit Our Web Site: www.dynabrade.com Email: Customer.Service@Dynabrade.com DYNABRADE, INC., 8989 Sheridan Drive • Clarence, NY 14031-1490 • Phone: 716-631-0100 • Fax: 716-631-2073 • International Fax: 716-631-2524 © DYNABRADE, INC., 2016...

This manual is also suitable for:

1068910694106901068710688

Table of Contents