• • Installation Operation Repair parts FOR MODELS: GPX 1210 GPX 1611 GPX 2011 GPX 2413 GPX 3013 OWNER'S RECORD Please complete for future reference. _______________________ ________ Model # Serial # ________________________________ Purchased from _______________________________ Date Purchased TRIANGLE ENGINEERING OF ARKANSAS, INC. E-mail: mail@trianglefans.com •...
Page 2
IMPORTANT: READ INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO INSTALL, OPERATE OR SERVICE THIS FAN. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE. Proper installation is required to ed) wiring must be used. DO NOT USE achieve maximum efficiency. It is nec- AN EXTENSION CORD.
Page 3
WIRING DIAGRAM Use wire nuts suitable for wire size. (2) required Fan Motor 120V, 60Hz Black Black Single Phase White White Power Supply Green Green Ground Screw REPAIR PARTS Motor Screen Guard Housing Blade Assembly When ordering repair parts, always give the following information: Shutter Assembly 1.
Page 4
TROUBLESHOOTING Symptom Possible Cause Corrective Action Defective Motor Repair or replace motor Fan does not operate Inspect power cord for damage. No power Check fuse or circuit breaker Intake Guard is excessively Clean guards. dirty Shutter is blocked or not Insuffi cient airfl...