Advertisement

Operator's Manual
For the DM100 S-VDR
Document Number DBS10912
Version Number
Date
P/N (hard copy)
1.0
October 2014
9302539-10

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DM100 S-VDR and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Danelec DM100 S-VDR

  • Page 1 Operator’s Manual For the DM100 S-VDR Document Number DBS10912 Version Number Date October 2014 P/N (hard copy) 9302539-10...
  • Page 2: Revision Record

    Operator's Manual for the DM100 S-VDR Copyright Danelec Marine A/S Revision record Version Date Description October 2014 Original issue of document DBS10912-10 Page 2/36...
  • Page 3: Table Of Contents

    Operator's Manual for the DM100 S-VDR Copyright Danelec Marine A/S Contents REVISION RECORD ......................2 SCOPE AND PURPOSE ................... 5 References ......................... 5 Terms and Abbreviations ................... 5 SYSTEM OVERVIEW ....................6 System overview for an S-VDR .................. 6 2.1.1 Data Acquisition Unit (DAU) ................
  • Page 4 Operator's Manual for the DM100 S-VDR Copyright Danelec Marine A/S Verification of the S-VDR functionality following service on any sensor ....25 Setting the IP address of the PC, windows 7 ............26 Connecting the PC to the S-VDR ................29 8.3.1...
  • Page 5: Scope And Purpose

    1.1 References DBS10704 Installation Manual for DM100/DM400 VDR compact Sensor Interface Unit DBS10885 Installation Manual for DM100 S-VDR DBS10911 Inspectors and Authorities Manual for DM100 S-VDR DBS10919 Installation manual for Remote Video Interface RVI 02-004(D) 1.2 Terms and Abbreviations Bridge Alarm Unit...
  • Page 6: System Overview

    Operator's Manual for the DM100 S-VDR Copyright Danelec Marine A/S 2 System overview System overview for an S-VDR The S-VDR is composed of the following units: Ethernet PoE STP CAT5 Capsule RS-422 Power Ethernet PoE STP CAT5 Remote video I/F...
  • Page 7: Float-Free Data Capsule

    Operator's Manual for the DM100 S-VDR Copyright Danelec Marine A/S 2.1.5 Float-free data capsule As an alternative to the fixed data capsule, a float-free capsule may be used instead. 2.1.6 Remote video interface (RVI) RADAR video is acquired using a Remote Video Interface (RVI). The RVI must be installed indoors;...
  • Page 8 Operator's Manual for the DM100 S-VDR Copyright Danelec Marine A/S 2.1.6.1 Maximum number of supported interfaces If needed, additional equipment may be used to make larger or non-standard configurations. The maximum number of supported interfaces for an S-VDR is listed below:...
  • Page 9: Operation

    Operator's Manual for the DM100 S-VDR Copyright Danelec Marine A/S Operation 3.1 Bridge alarm Unit The BAU is the primary user interface for an installed operational S-VDR. It serves two purposes: • Alarm display • Interface for initiating a backup on the VDR data disk 3.1.1 Alarm display...
  • Page 10 Operator's Manual for the DM100 S-VDR Copyright Danelec Marine A/S This VDR data disk must be replaced if it becomes full (which is unlikely under normal circumstances). Alternatively, data from the disk must be transferred to another media, and space on the disk can be manually released.
  • Page 11: Operation Dm100 Dau

    Operator's Manual for the DM100 S-VDR Copyright Danelec Marine A/S 4 Operation DM100 DAU The door to the DAU must be locked after the S-VDR is installed and operating normally. This section of the manual is only relevant during installation and service, or if the (USB) VDR data disk has to be removed following a serious incident.
  • Page 12: Dpu

    Operator's Manual for the DM100 S-VDR Copyright Danelec Marine A/S 4.1 DPU The DPU is the main computer in the system. It is basically a PC, but it has been designed from scratch in a completely different manner in order to withstand environmental stress which far exceeds what an ordinary industrial PC can sustain.
  • Page 13: Battery Switch

    Operator's Manual for the DM100 S-VDR Copyright Danelec Marine A/S 4.1.4 Battery switch The battery switch indirectly controls a relay between DPU and the battery pack. When switching the S-VDR off, do the following: Pop out the AC breaker and move the battery switch to its “OFF”...
  • Page 14: Vdr Status Led

    Operator's Manual for the DM100 S-VDR Copyright Danelec Marine A/S 4.1.5 VDR status LED The status of the system is displayed using a tri-color LED. The BAU will display text messages and error codes explaining the problems, if the LED becomes yellow or red.
  • Page 15: Operation Of Standard Rvi 02-004 And Rvi 02-004D (Poe)

    Operator's Manual for the DM100 S-VDR Copyright Danelec Marine A/S 5 Operation of standard RVI 02-004 and RVI 02-004D (PoE) The DM100 will normally use an RVI 02-004 and RVI 02-004D for image capture. Another type exists (see section 6) which may be used if the “Power over Ethernet” ports on the DPU are used for other purposes.
  • Page 16: Operation Of Rvi With Ac Power Supply

    Operator's Manual for the DM100 S-VDR Copyright Danelec Marine A/S 6 Operation of RVI with AC power supply This type is only used if the “Power over Ethernet” ports on the DPU are used for other purposes. RVI address Ethernet port...
  • Page 17: Error Codes

    Operator's Manual for the DM100 S-VDR Copyright Danelec Marine A/S 7 Error codes Error codes and messages will be displayed by the BAU when errors are detected. An “R” after the error code denotes a repetitive alarm; see section 3.1.1.1.
  • Page 18 Operator's Manual for the DM100 S-VDR Copyright Danelec Marine A/S AUDIO One or more microphones are using too much power. The cabling Power short circuit and microphones must be checked. STATUS The system is not receiving UTC from the GPS. Check that the UTC timeout GPS is on.
  • Page 19 Operator's Manual for the DM100 S-VDR Copyright Danelec Marine A/S when the VDR is operating from the battery only. This message will not appear if the battery pack is new and was fully charged, since the VDR will power down automatically after two hours when operating from the batteries (well before the voltage drops below 16V).
  • Page 20 Operator's Manual for the DM100 S-VDR Copyright Danelec Marine A/S The primary fan in the DPU has failed. The secondary fan in DPU CPU fan failed will serve as a backup until the problem is rectified. The VDR will be able to operate normally unless the secondary fan also fails (error 191).
  • Page 21 Operator's Manual for the DM100 S-VDR Copyright Danelec Marine A/S occurred within a given interval. More sophisticated measures than just retrying to write data were needed in order to fix the problem. The most likely cause is serious communication problems or a defective VDR data disk.
  • Page 22 Operator's Manual for the DM100 S-VDR Copyright Danelec Marine A/S write errors detected by the fixed capsule over a period of time. The most likely cause is serious communication problems or a defective fixed capsule. CAPSULE, too many Too many read-errors (reading back data from the fixed capsule) read errors have been detected by the DAU over a period of time.
  • Page 23: Additional Error Codes For Installations Utilizing A Siu And

    Operator's Manual for the DM100 S-VDR Copyright Danelec Marine A/S 7.2 Additional error codes for installations utilizing a SIU and 2 SERIAL 400- Mandatory serial data is not received. Check that the source is Timeout on SIxx on. Check the signal from the source (serial monitor in VDR explorer, WEB status or VGA status display).
  • Page 24 Operator's Manual for the DM100 S-VDR Copyright Danelec Marine A/S ANALOG module 2 If only one module is affected: Missing (AN16-31) A module has been removed or has failed. Check that the DIGITAL module 5 module is installed correctly. Missing (DI64-79) If installed in a modular SIU, the blue “link”...
  • Page 25: Service And Maintenance

    8 Service and maintenance The S-VDR requires an annual performance test carried out by a certified service organization. Please refer to “Installation Manual for DM100 S-VDR” for further details. 8.1 Verification of the S-VDR functionality following service on any sensor It is a requirement of the S-VDR standard that the functionally of the S-VDR is verified followed service on any sensor (e.g.
  • Page 26: Setting The Ip Address Of The Pc, Windows 7

    Operator's Manual for the DM100 S-VDR Copyright Danelec Marine A/S 8.2 Setting the IP address of the PC, windows 7 The default IP address of the S-VDR is 10.0.0.100 (255.255.255.0). The PC must use an IP address within the same range.
  • Page 27 Operator's Manual for the DM100 S-VDR Copyright Danelec Marine A/S Right click on the icon representing your Ethernet adaptor and select “Properties” from the drop down menu. Open the “Properties” for “Internet Protocol 4”. DBS10912-10 Page 27/36...
  • Page 28 Operator's Manual for the DM100 S-VDR Copyright Danelec Marine A/S Set the new IP address for the PC and click on “OK” (It is a good idea to write down the previous settings). Click on “OK” DBS10912-10 Page 28/36...
  • Page 29: Connecting The Pc To The S-Vdr

    Operator's Manual for the DM100 S-VDR Copyright Danelec Marine A/S 8.3 Connecting the PC to the S-VDR Connect the PC to the S-VDR using a standard CAT5 patch cable. Open an Internet browser on the PC Type in the IP address of the S-VDR in the browser address field. The IP address of the S-VDR is 10.0.0.100 (default).
  • Page 30 Operator's Manual for the DM100 S-VDR Copyright Danelec Marine A/S Windows will probably display a security warning. Click “Yes” to start the program. The following program will start: If necessary, change the IP address. The default IP address is set to the default at program start.
  • Page 31 Operator's Manual for the DM100 S-VDR Copyright Danelec Marine A/S Select a folder for the report and data files. Wait for the verification to finish. Press “Yes” to open report in a web-browser. DBS10912-10 Page 31/36...
  • Page 32: Examination Of The Report

    Operator's Manual for the DM100 S-VDR Copyright Danelec Marine A/S 8.3.2 Examination of the report The following tests have been made. The report starts with a summary. DBS10912-10 Page 32/36...
  • Page 33 Operator's Manual for the DM100 S-VDR Copyright Danelec Marine A/S 8.3.2.1 Verification of microphone functionality The self-test in the microphones is activated and the result is printed in the report – either passed or failed 8.3.2.2 Verification of analog data...
  • Page 34 Operator's Manual for the DM100 S-VDR Copyright Danelec Marine A/S 8.3.2.4 Verification of data on the audio tracks It is recommended that someone speaks on the bridge for the first 100 seconds after the verification program is started – i.e. during the microphone test and until download of data starts. If possible also use the VHF radio.
  • Page 35 Operator's Manual for the DM100 S-VDR Copyright Danelec Marine A/S 8.3.2.6 Verification of video data It is recommended that the radar(s) is/are switched on before and after the verification tool is started. Passed: The image contains information. Error: The image contains little or no information.
  • Page 36: List Of Most Common Spare Parts

    3000671 Beacon replacement kit 3302519 50m zero halogen FTP CAT5 cable from DPU to MK4 fixed capsule or float-free capsule 7302530 Boot flash for DM100 S-VDR 9302533 Set of manuals for the DM100 S-VDR (Hardcopy and CD) DBS10912-10 Page 36/36...

Table of Contents