Introduction This manual details the proper steps for installing, operating and maintaining the Eriez Vibratory Feeder. Careful attention to these requirements will assure the most efficient and dependable performance of this equipment. If there are any questions or comments about the manual, please call Eriez at 814/835-6000 for Vibratory Feeder assistance.
ELECTRICAL CONNECTIONS of the vibratory elements. NOTE: The Eriez Vibratory HD-C Feeder is designed to be IMPORTANT NOTE: operated from an AC source through a special Eriez 30Hz Special Trays and Attachments control (see IOM - 414).
Figure 2 displacement. How to Measure Displacement Position an Eriez displacement sticker on the outer side As a guide to the stiffness of individual tuning springs, of the tray, near the rear of the tray and at an angle of each spring is marked with a code number example, 25°...
Do not allow hands, fingers and other body parts more than .219" (5.6 mm) without load for HD-46C, to be caught between the equipment and nearby HD-56C and HD-66C.
BODY HOUSING Figure 5 Figure 7 4. If the coil is defective, the entire E-frame assembly FEEDER AIR GAPS including the coil must be replaced (order from Eriez parts list). HD-46C HD-56C HD-66C 5. In reassembling the unit, first center the armature at the bottom of the body cavity;...
The following applies: SPRING CHANGE OR MODEL REAR SPRINGS/PLY FRONT SPRINGS/PLY REPLACEMENT HD-46C 2-13 ply, 1-9 13 ply Refer to the Parts List Drawing and Figs. 8 & 9. Although the non-metallic springs used in the HD-56C 4-13 ply...
TABLE 1. TORQUE CHART 5. Stand the armature and spring stack assembly on a 46 & 56 Series non-magnetic surface (I.E. wooden table) as shown in Figure 9. NOTE: Keep armature away from any Torque Part Bolt steel parts and surfaces. Size m-kgs ft-lbs...
Page 10
The engine-driven power plant is shut down. new Hi-Vi method incorporates a lifetime permanent rare earth magnet and is operated directly from an alternating current line through Eriez 30Hz control. POTENTIOMETER In the Hi-Vi method, the spring-mounted mass is POWER...
7. Spring Failure may have affected performance. Reassemble in See maintenance instructions. Disassemble for accordance with printed instructions or consult Eriez. examination. Tuning spring failure will show up 3. Loose Spring Clamp or Tray Mounting Bolts as white areas. Order new parts from factory and Tighten all bolts.