mr
steam
.
___________________________________________________________________________________
Digital 30-Minute Timer
Electronic Interval Timer for
Mr.Steam CU Commercial Steambaths
Installation and Operating Manual
FUNCTIONALITY OF THE TIMESWITCH
The countdown timer uses a relay to switch the steam
solenoid on. During the preset running time, the relay
energizes and activates the connected steam solenoid by
closing a circuit. After the time has elapsed, the relay
deenergizes and deactivates the connected steam solenoid
by opening the circuit again. THE TIMER MAY ONLY BE
OPERATED AFTER INSTALLATION IN A PROTECTIVE
HOUSING. A large 3-digit LCD display is provided for
monitoring the countdown of the timer.
BEFORE USE
Before installing and using this timer, it is absolutely nec-
essary that you read this operating manual thoroughly.
SAFETY INSTRUCTIONS
This timer may only be installed by a qualified, licensed
electrician and must be installed in accordance with
National and local codes.
WA R N I N G
SHOCK HAZARD! Install the timer per
these instructions before connecting to the main supply.
Never touch live contacts or components.
Protection from contact with the line
WA R N I N G
voltage components must be achieved by proper instal-
lation in a 4 x 4 junction box. When installing the
timer, ensure the fastening sliders prevent the timer
from being removed.
DO NOT install the timer in a wet or
WA R N I N G
damp location.
DO NOT install the timer inside the
WA R N I N G
steam room.
IMPORTANT NOTE:
As you follow these instructions, you will notice
warning and caution symbols. This information is important for the safe and
efficient installation and operation of this generator. These are types of
potential hazards that may occur during this installation and operation:
.
mr
steam
®
Sussman-Automatic Corp.
®
43-20 34th Street
info@mrsteam.com
Long Island City, NY 11101
www.mrsteam.com
TEL
9410 S. La Cienega Blvd.
Inglewood CA 90301
: 718-937-4500
: 718-472-3256
TEL
FAX
®
99216DIG
1. INSTALLING THE TIMER
DIP SWITCHES SETTING
Figure 1 shows the default setting for the timer.
The timer is factory set to run for 30 minutes.
1
ON
Figure 1: Default Settings
C A U T I O N
states a hazard
may cause serious injury or death if
precautions are not followed.
: 310-216-6565
: 310-216-2944
FAX
30-MINUTE TIMER
2
3
4
Maximum run time can be set at 15, 30 or 60
minutes. Use switches 3 and 4 to set run time:
Run
Time
15
min.
30
min.
60
min.
WA R N I N G
where minor injury or product damage may
occur if you do not follow instruc tions.
5
6
Switch Switch
3
4
OFF
OFF
OFF
ON
ON
OFF
signals a situation
PUR 100383 REV 2/10
Need help?
Do you have a question about the 99216DIG and is the answer not in the manual?
Questions and answers