I. GENERAL. The Model 154XST Strobe Light is a UL listed visual signal for hazardous and marine locations and has been investigated by UL as meeting Type 4X (water tight and corrosion resistant) enclo- sure requirements.
Page 3
The dome guard (Part #K8449090) may be used as an accessory. It is mounted on the 154XST using the two supplied #8-32 screws. Adjust the tension on the screws until the dome guard is square with the housing.
Page 4
WARNING High voltages are present inside the light assembly. Wait at least 5 minutes after shutting off the power before servicing this unit. To change the flash tube, proceed as follows: 1. To remove the globe assembly, grasp the metal ring attached to the globe and turn it counter- clockwise.
Page 5
Manufacturer’s Representative. At this time a brief explanation of the service requested, or the nature of the malfunction, should be provided. Address all communications and shipments to: FEDERAL SIGNAL CORPORATION Industrial Systems Service Department 2645 Federal Signal Drive University Park, IL 60484-3167...
Page 6
290A4344 English A. Ground screw (green) B. 1/4-20 set screw C. 3/4-14 N.P.T. D. Field wiring E. Wrap power leads once around washer then pull through casting.
Page 7
290A4375 English A. New flash tube (K149122) B. Used flash tube tends to discolor in areas shown, and should be replaced. Industrial Systems 2645 Federal Signal Drive • University Park, IL 60484-3167 Tel: 708-534-4756 • Fax: 708-534-4852 Email: elp@federalsignal.com • www.federalsignal-indust.com...