  • Page 1 Safe power anywhere Quick Installation Ecoport 800...
  • Page 3 The quick guide only describes the initial installation of the Ecoport 800 using the operating panel. A service technician needs to install the Ecoport 800 first. This quick guide does not replace the operating manual, which is part of the delivery.
  • Page 4: General Safety Information

    Identifies a possibly dangerous situation, which may result in light ATTENTION bodily harm. Identifies a notice, which must be considered. The Siqens fuel cell NOTES must not be operated in explosive environments. General Safety Information...
  • Page 5: Electric Shock Hazard

    Do not inhale exhaust gases directly or permanently. Instead lead them out into the open air with the supplied exhaust system. Do not smoke when handling the Siqens fuel cell or Siqens fuel cartridges. Keep away from heat and ignition sources.
  • Page 6 The Ecoport must be operate and stored in a horizontal position. The Siqens fuel cell is not waterproof! Make sure that no water can penetrate the device. Do not operate the Siqens fuel cell and Siqens fuel cartridges at temperatures above 50°C...
  • Page 7 (H301 + H311 + H331) Causes damage to organs. (H370). Use only undamaged containers with suitable terminals with SIQENS fuel cell. Follow operating instruc- tions. IF SWALLOWED: Immediately call a NATIONAL POISONS INFORMATION SERVICE. (UK (00 44) (1 71) 6 35 - 91 91 ).
  • Page 8 CONTAMINANTS IN THE METHANOL ATTENTION The original QE CHARGE methanol cartridges contain methanol approved by Siqens for the Ecoport. Contaminants or foreign com- ponents in the methanol can cause irreversible damage to the unit and may void the warranty or guarantee.
  • Page 9: Explosion Danger

    Ecoport 800 Safe battery handling It is imperative that another person is present, in case of emergen- NOTICE cies, when working on the batteries. These instructions must be observed in addition to the instructions of the battery manufactu- rer. ACID BURN HAZARD DANGER Keep soap and water ready in case battery acid contacts skin.
  • Page 10 Safety Information Only use cycle-resistant, deep-discharge capable batteries, no WARNINGS starter batteries. Never charge frozen batteries. Avoid battery short-circuits. Ensure good ventilation of the battery to dissipate any gases. Carefully lay the battery connection cable and check for improper heating under load. Periodically check the battery in the area of vibrating components for chafing and insulation problems.
  • Page 11 Ecoport 800...
  • Page 12 The Siqens Fuel Cell System Air Intake Methanol feed Ecoport 800 Operating Panel Connected to the Ecoport via ƒ the data cable Operated via touch display ƒ Battery Battery load cable ƒ with battery voltage measuring lead (16mm , recommen-...
  • Page 13 Ecoport 800 Ecoport 800 800 Watts electrical ƒ power (peak) 24V DC ƒ 0,6 l/kWh ƒ Suitable for technical ƒ External switching device Exhaust methanol Operate the Ecoport only Device can be controlled ƒ ƒ Application range ƒ with an exhaust system with a potential-free -20°...
  • Page 14 Dimensions Installation in a closed room: To prevent a heat build-up, a distance of 50 mm must be maintained to other assembly parts on all sides. Side view...
  • Page 15 Front view...
  • Page 16 Exhaust air kit consisting of: 1x corrugated pipe Ø100mm (approx. ƒ 1 metre), 1x corrugated pipe Ø70mm (approx. 1 metre), 3x pipe clamp, 1x ventilation grille Ecoport 800 Connections Recommended cable cross section from the Ecoport 800 to the battery Cable length Cross section from 13 m 16 mm²...
  • Page 17 Air intake Exhaust Data interface to the control panel Methanol feed Signal connector Load plug and battery voltage measurement 24 V...
  • Page 18: First Installation

    Check that the supply and exhaust hoses are free and ensure a safe supply and ƒ exhaust air flow. IMPORTANT: Observe the safety instructions in this operating manual during instal- lation. If other lengths of the exhaust system are required, contact Siqens technical support.
  • Page 19 Ecoport 800 Connect the QE CHARGE methanol cartridge to the Ecoport Connect the QE CHARGE methanol cartridge to the methanol feed (1.5 m) of the Ecoport 800. So as to ensure a safe operation, do not position the QE CHARGE methanol cartridge above the level of the Ecoport.
  • Page 20 First Installation Connect the Battery to the Ecoport Connect the battery to the Ecoport battery port using the load cable. Nominal battery voltage: 24 V; supported battery types: lithium, lead acid, lead AGM, lead gel IMPORTANT: When connecting the cables, be aware of the polarity! The Ecoport can only operate with a battery.
  • Page 21 Ecoport 800 Connect Control Panel to the Ecoport Use the data cable to connect the operating panel with the Ecoport 800.
  • Page 22 First Installation Automatic Connection between the Control Panel and the Ecoport The connection to the Ecoport 800 will be established. A user input is not necessary.
  • Page 23 Ecoport 800 Start-up Screen The following settings must be implemented to ensure a safe operation of the Ecoport 800.
  • Page 24 First Installation Select Turn-on Criteria The type of start signal can be configured using the settings menu. You can choose between “Only manual”, “Battery threshold”, “External input”. When choosing “Battery threshold”, the battery type and the turn-on threshold need to be defined. When choosing “External input” no additional settings are required..
  • Page 25: Battery Selection

    Ecoport 800 Battery Selection The battery type can be changed in the settings menu. Select the desired battery type using the arrows. (Supported battery types: Lithium, lead acid, lead AGM, lead gel)
  • Page 26: Important Notice

    First Installation Adjust Turn-on Voltage IMPORTANT NOTICE The Ecoport starts once the set lower voltage threshold is reached. This should not be too low, since to start the system approx. 100Wh are needed. To prevent damage to the battery, the Ecoport shuts off at a battery voltage of 23.0 V. Charging the battery with the Ecoport is then no longer possible.
  • Page 27 Ecoport 800 Initial Start of the Ecoport 800 Now the Ecoport 800 must be started manually.
  • Page 28 First Installation Warming up The warm up phase starts automatically. The Ecoport starts charging the bat- tery after approx. 30 minutes. You can stop this procedure at any time.
  • Page 29 Ecoport 800 Operation (charging mode) The screen showing the operating status appears automatically after the warm up phase. The charging procedure (charging phase) begins. For further steps, please consult the information in the Operating Instruc- tions.
  • Page 30 Symbols Go to home screen Go to settings menu Show information Show fuel tank status System Status OK Show battery status Show performance data...
  • Page 31 Ecoport 800 Notes...
  • Page 32 Tel +49 (0)89 452 44 63-0 Fax +49 (0)89 452 44 63-22 E-Mail info@siqens.de Web www.siqens.de Changes and errors excepted. Status as of June 2018. All technical data under test conditions of © 2018 Siqens GmbH. All rights reserved. 20°C ambient temperature. Ordner number: E-093-000019...