  • Page 1 ® DSVII-SC User’s Manual Part Number 4040-00701-00 Version 1.11...
  • Page 2 Datastrip make no claims of suitability for any particular application. Datastrip will not be held liable for direct or indirect damages or other losses due to loss of data, reliability or performance issues relating to Datastrip-provided equipment or software.
  • Page 3: Table Of Contents

    External Compact Flash Slot .....................15 11.5 USB Ports ...........................15 11.6 Smart Card Slot........................15 Regulatory Compliance Statement .................16 Service & Support......................17 Available Parts, Supplies and Accessories..............18 Copyright © 2006 by Datastrip, Inc. All rights reserved. Reproduction in whole or in part is prohibited.
  • Page 4: Overview

    Therefore, Figure-2 may not correspond exactly to the shipping box contents. Copyright © 2006 by Datastrip, Inc. All rights reserved. Reproduction in whole or in part is prohibited.
  • Page 5 Documentation, including: User Manual (on CD), Release Notes, End User License Agreement, and Quick-Reference Guide Figure 2: Shipping Box Contents Please retain the shipping box in the event you need to return your product for service. Copyright © 2006 by Datastrip, Inc. All rights reserved. Reproduction in whole or in part is prohibited.
  • Page 6: Initial Setup

    Each unit is shipped with one Li-Ion battery installed, though disconnected. To enable the battery, you will need ® to remove the rear cover and plug the battery connector into the mating connector on the DSVII-SC • The battery is shipped fully charged, however, there is a small amount of self-discharge even when the battery is disconnected.
  • Page 7: Operation

    DSVII-SC User Manual, Version 1.11 ® Operation Startup Sequence: • To begin operation, depress and hold the power button on the front of the DSVII-SC ® unit. • Release the button when a single beep is heard. • Two additional beeps acknowledge that power has been activated. The keypad and LCD backlights will turn on.
  • Page 8 DSVII-SC User Manual, Version 1.11 ® Copyright © 2006 by Datastrip, Inc. All rights reserved. Reproduction in whole or in part is prohibited.
  • Page 9 DISPOSAL: Always consult and obey all international, federal, provincial/state, and local hazardous waste disposal laws. Certain jurisdictions require recycling of this spent product. Copyright © 2006 by Datastrip, Inc. All rights reserved. Reproduction in whole or in part is prohibited.
  • Page 10: Cleaning

    Cleaning The LCD screen and fingerprint sensor may need periodic cleaning to ensure continued performance. Use only the Datastrip-approved cleaning-kit, to remove dirt, oils, grease, dust and foreign matter. To clean the LCD display or fingerprint sensor: Make sure the DSVII-SC ®...
  • Page 11: Troubleshooting

    Plug in the AC power adapter to change the battery. Copyright © 2006 by Datastrip, Inc. All rights reserved. Reproduction in whole or in part is prohibited.
  • Page 12: Hardware Specifications

    12 VDC @ 2.5 Amps maximum output. • Environmental: Temperature: +5ºC to +40ºC (operating), -25ºC to +75ºC (storage). Humidity: 95% RH, non-condensing at +40ºC. Copyright © 2006 by Datastrip, Inc. All rights reserved. Reproduction in whole or in part is prohibited.
  • Page 13: Hardware Features

    USB ports, CF-slot (not visible) and 10/100 LAN port. NOTE: For developers, establishing an “ActiveSync” serial connection with a host-PC will require a Datastrip serial-port cable plus a null-modem cable. These are available through Datastrip Inc., Datastrip Ltd, or your authorized Datastrip reseller. The serial cable and null-modem cable is supplied free with Datastrip2D SDK.
  • Page 14 (This view is looking into the connector on the cable) WARNING: External equipment should connect only to the 9D-Subminiature male connector – NEVER directly to the 9-pin connector on the DSVII-SC ® unit. The following table details the signal configuration that exists when this cable is used on the COM1: port of the DSVII-SC ®...
  • Page 15: External Compact Flash Slot

    LCD screen, on the same side of the unit as the SmartCard slot. The typical operating range is 0 to 3 cm. Copyright © 2006 by Datastrip, Inc. All rights reserved. Reproduction in whole or in part is prohibited.
  • Page 16: Regulatory Compliance Statement

    Consult the dealer or an experienced radio/TV technician for help Note: The DSVII-SC is fully compliant with the requirements of FCC Part 15 and the EU Low Voltage Directive (72/73/EEC) for Conducted Emissions only when used with the Datastrip-supplied External Power Supply (DS P/N 3090-01225-02) and External Power Supply AC Linecord (DS P/N 3008-60163-01).
  • Page 17: Service & Support

    Datastrip will return all RMA equipment shipping-prepaid as well. Failure to follow this requirement will result in LENGTHY delays while your package is held by Customs. For parts, supplies and accessories, place your order through your authorized Datastrip reseller, or by contacting Datastrip Limited.
  • Page 18: Available Parts, Supplies And Accessories

    Battery Pack, Lithium-Ion, Polymer Gel, 7.4V, 3000 3091-03000-01 DSVII-SC ® External Power Supply: 3090-01225-02 (Universal 90-240VAC 50/60Hz input) External power supply AC line-cord: 3008-60162-02 (USA): Copyright © 2006 by Datastrip, Inc. All rights reserved. Reproduction in whole or in part is prohibited.
  • Page 19 Stud 2010-55022 Wash 7246-57038-017 Wash 7200-62050-060 Cleaning Kit: 2000-82001 Please contact Datastrip Ltd or an authorized reseller for a complete list of options and accessories, pricing and availability information. DSVII-SC ® Copyright © 2006 by Datastrip, Inc. All rights reserved.

Table of Contents