Advertisement

Quick Links

44208-00006-000 DSV3-SP User's Manual
Title: DSV3-SP User's Manual
Document Number: 4208-00006-000
Revision: 0B
Author:
__________________________________________________
John Hufnagel, Director of Operations
Reviewer:
__________________________________________________
Joe Ruggiero, Lead Software Engineer
Reviewer:
__________________________________________________
Scott Robinson, Hardware Manager
Reviewer:
__________________________________________________
Reviewer:
__________________________________________________
Joe Delaney, VP of Sales & Marketing
Reviewer:
__________________________________________________
Approver:
__________________________________________________
Dan Tuck, VP of Engineering & Operations
Steve Blackmore, CEO
Brian Feick, CFO
2/12/2009
Date:___________
Date:___________
Date:___________
Date:___________
Date:___________
Date:___________
Date:___________
Rev 0B

Advertisement

Table of Contents
loading

Summary of Contents for Datastrip DSV3-SP

  • Page 1 44208-00006-000 DSV3-SP User’s Manual Rev 0B 2/12/2009 Title: DSV3-SP User’s Manual Document Number: 4208-00006-000 Revision: 0B Author: __________________________________________________ Date:___________ John Hufnagel, Director of Operations Reviewer: __________________________________________________ Date:___________ Joe Ruggiero, Lead Software Engineer Reviewer: __________________________________________________ Date:___________ Scott Robinson, Hardware Manager Reviewer:...
  • Page 2 44208-00006-000 DSV3-SP User’s Manual Rev 0B 2/12/2009 DSV3-SP User’s Manual Copyright © 2009 by Datastrip, Inc. All rights reserved. Reproduction in whole or in part is prohibited.
  • Page 3: Revision History

    Datastrip makes no claims of suitability for any particular application. Datastrip will not be held liable for direct or indirect damages, or other losses due to loss of data, reliability, or performance issues relating to Datastrip-provided equipment or software.
  • Page 4 DSV3 Software Update Procedure: Using a USB Flash Drive ...............20 7.1.3 DSV3 Software Update Procedure: Using an FTP site ................20 ....................20 OADING MARTCARD IRMWARE PDATES Copyright © 2009 by Datastrip, Inc. All rights reserved. Reproduction in whole or in part is prohibited.
  • Page 5 12.1 I/O ............................32 OCKING TATION 12.2 .....................32 DJUSTING THE OCKING TATION ACKREST TROUBLESHOOTING ........................32 AVAILABLE PARTS, SUPPLIES, AND ACCESSORIES............34 SERVICE & SUPPORT ........................35 Copyright © 2009 by Datastrip, Inc. All rights reserved. Reproduction in whole or in part is prohibited.
  • Page 6: Overview

    • Airports • Military Bases and • Transportation Ships • Travel & Border Control • Financial Institutions • Seaports • Schools and Universities Copyright © 2009 by Datastrip, Inc. All rights reserved. Reproduction in whole or in part is prohibited.
  • Page 7: Unpacking & Inventory

    • The unit may be operated when connected via the AC adapter, regardless of the charge state of the internal battery. Please refer to Section 4.44.4“Battery Charging and Replacement”, for additional instructions and safety information. Copyright © 2009 by Datastrip, Inc. All rights reserved. Reproduction in whole or in part is prohibited.
  • Page 8: System Overview

    Fingerprint Sensor Speaker Ambient Light Sensor Function Buttons Function Buttons Navigation Button Power Button Microphone Power Status LED Indicator (tri-color) Programmable LED Status Indicators Copyright © 2009 by Datastrip, Inc. All rights reserved. Reproduction in whole or in part is prohibited.
  • Page 9: Led I Ndicators

    • Solid: LED is On continuously. • Continuous with Color Toggle: LED is On continuously, alternating evenly between the two colors each second. Copyright © 2009 by Datastrip, Inc. All rights reserved. Reproduction in whole or in part is prohibited.
  • Page 10: T One I Ndicators

    Remove the old battery and replace it with a charged battery within 30 seconds to prevent the unit from shutting down. Replace the battery-access cover and re-fasten it by tightening the quick release bails. Quick Release Quick Release Bails Receptacles Copyright © 2009 by Datastrip, Inc. All rights reserved. Reproduction in whole or in part is prohibited.
  • Page 11: F Unction B Uttons

    This battery is automatically recharged by the system and does not require any operator service. CAUTION! Use ONLY approved replacement batteries and power adapters as provided by Datastrip. CAUTION! Battery has a risk of FIRE, EXPLOSION, or BURNS. DO NOT: short-circuit the battery terminals;...
  • Page 12: Fingerprint Sensor Calibration

    The DSV3 mobile terminal is compliant with fingerprint matching algorithms from a variety of the industry leading vendors such as: Identix, Cogent, Bioscrypt, Motorola, and NEC. However, the Identix algorithm is the only algorithm directly available from Datastrip for the DSV3 terminal at this time. 4.8.2...
  • Page 13: Compact Flash (Cfio) Slot

    The DSV3 has a SD slot that is accessible under the rubber I/O port cover. It is optimized (recessed) for Datastrip’s 802.11 peripheral; however, it is a standard SD slot, so a range of SD memory and SDIO peripheral devices may be used.
  • Page 14: Audio Headset Jack

    Step 2: Remove (unscrew) the rubber stylus holder from the old bay door, and fasten (screw) it to the rear of the mobile terminal. Stylus Holder & Screws Copyright © 2009 by Datastrip, Inc. All rights reserved. Reproduction in whole or in part is prohibited.
  • Page 15: Module

    To install the Point & Shoot Scanner peripheral in the integrated peripheral bay, follow the same steps as for the Digital Still Camera (DSC) peripheral module (see section 4.12.1). Copyright © 2009 by Datastrip, Inc. All rights reserved. Reproduction in whole or in part is prohibited.
  • Page 16: Basic Operation

    USB mouse). The DSV3 stylus can be found in the stylus holder on the back of the DSV3-SP and the front of the unit the DSV3-EP. The following actions are available with the stylus: •...
  • Page 17 Everything in the system is off (except the embedded controller). Push the power button to start the unit and return to a Fully On state. Copyright © 2009 by Datastrip, Inc. All rights reserved. Reproduction in whole or in part is prohibited.
  • Page 18: Battery Charge Level States

    • An error beep sounds when the battery charge level is critical. Copyright © 2009 by Datastrip, Inc. All rights reserved. Reproduction in whole or in part is prohibited.
  • Page 19: Software Utilities

    DsVerify Registry Install Utility (DsVerifyRegInst.exe) This application registers all of the Datastrip specific components of the DSV3 that are needed to read/write Smart Cards, scan documents, operate the Fingerprint sensor, and so forth. It is typically run after a software update to register the components in sequence, and it reports any errors if it does not succeed.
  • Page 20: Loading Software And Firmware

    • Power up the unit • The DSV3 registration program will automatically open. Select the button for the device that you are registering (DSV3-SP or DSV3-EP). Select [OK] and wait. (This process will take a few seconds). • Click [Ok] in the “Hurray!” box when it appears, then close the application window.
  • Page 21: Dsv3 Software Update Procedure: Using A Usb Flash Drive

    • Power up the unit • The DSV3 registration program will automatically open. Select the button for the device that you are registering (DSV3-SP or DSV3-EP). Select [OK] and wait. (This process can take from a few seconds to up to 45 seconds).
  • Page 22: L Oading D Igital S Till C Amera F Irmware U Pdates

    • Double tap the latest release e.g. “PIC_FW_V401.hex” to select it. • Click the button “Update PIC Firmware”. • Reboot to complete update. Copyright © 2009 by Datastrip, Inc. All rights reserved. Reproduction in whole or in part is prohibited.
  • Page 23: Dsv3-Sp Product Specifications

    [6.6”(W) x 7.0”(L)] 13.56 MHz Operating Frequency: Contact Smartcard Reader (optional) Specification: ISO 781 Connector: 8X Landing Style Contacts 100K Min Insertion Cycles Copyright © 2009 by Datastrip, Inc. All rights reserved. Reproduction in whole or in part is prohibited.
  • Page 24: Regulatory Compliance Statement

    • Consult the dealer or an experienced radio/TV technician for help. WARNING: Changes or modification to Datastrip DSV3 not expressly approved by the party responsible for assuring compliance could void the user's authority to operate the equipment in a safe or otherwise regulatory compliant manner.
  • Page 25: Software Demo Applications

    50 to 60 times a second. ON, OFF Specifies whether or not to use flash illumination during preview mode. Preview Illumination Mode Copyright © 2009 by Datastrip, Inc. All rights reserved. Reproduction in whole or in part is prohibited.
  • Page 26 Main Screen Clicking the Datastrip logo will return the user to the Main Screen and will reset the scanner subsystem (if the unit is a DSV3 scanner model). On the Main Screen, a user can perform the following operations: •...
  • Page 27 “Use GUI Buttons” box, and return to the Main Screen. The GUI buttons “Photo”, “Text, and “Fingerprint” will be displayed above the windows. • Clicking on the “Datastrip” logo button will bring the application back to the Main Screen. • Clicking on the ‘Toolbox’ has no effect.
  • Page 28: Piv C Ard And Chuid V Erifier (D Atastrip Pivc Ard _Chuidv Erifier . Exe )

    Expired or Abnormal Expiration Data. b. Non Authorized or incorrect data in the following fields i. FASC-N ii. Agency Code iii. Organization Code Copyright © 2009 by Datastrip, Inc. All rights reserved. Reproduction in whole or in part is prohibited.
  • Page 29 Con Button: The Con or Configure button is used to setup the configuration for acceptance of a PIV card based on the following fields: • FASC-N • Agency Code • Organization Code Copyright © 2009 by Datastrip, Inc. All rights reserved. Reproduction in whole or in part is prohibited.
  • Page 30: D Ata C Apture E Nrollment A Pplication (D Ata C Apture . Exe )

    • Add and remove files from the DSV3 • Copy data between the DSV3 and the PC • Use the connection to debug programs you develop. Copyright © 2009 by Datastrip, Inc. All rights reserved. Reproduction in whole or in part is prohibited.
  • Page 31: Hardware/Software Requirements

    • ActiveSync version 3.7.1 or later installed on the host PC (Version 4.5 recommended) • A DSV3 terminal. • USB 2.0 to Mini B Cable (Datastrip sales code DSVOSCAUSB). • Datastrip DSV3_Turbo_USB Sync Setup utility found on the DSV3 User Manual CD. 11.1.2 PC Configuration for USB 2.0 ActiveSync (First Time Only) •...
  • Page 32: Disconnect

    High Density Connector Guide Holes for Docking Station Copyright © 2009 by Datastrip, Inc. All rights reserved. Reproduction in whole or in part is prohibited.
  • Page 33: D Ocking S Tation I/O

    Adjustment Plunger to adjust the backrest correctly to ensure proper operation. To use the docking station with the DSV3-SP, ensure that the plastic backrest support is in the forward position. This is done by removing the 2 Philips- head screws in the plastic backrest support, repositioning the...
  • Page 34 44208-00006-000 DSV3-SP User’s Manual Rev 0B 2/12/2009 Copyright © 2009 by Datastrip, Inc. All rights reserved. Reproduction in whole or in part is prohibited.
  • Page 35: Available Parts, Supplies, And Accessories

    Available Parts, Supplies, and Accessories The following options, accessories, and replacement parts are available for the DSV3 mobile terminals. Please contact Datastrip or an authorized reseller for a complete list, and for pricing and availability. ACCESSORIES / SPARE PARTS Stylus D-Ring and Shoulder Strap For applications that require over-shoulder carrying of DSV3 devices.
  • Page 36: Service & Support

    Please use the original shipping carton and packing materials whenever possible. Please ensure you send your package PREPAID or it will not be accepted. Do not ship collect. Datastrip will return all RMA equipment shipping prepaid as well. Failure to follow this requirement will result in delays.

Table of Contents