The 275HP / 500HP is a HIGH VOLTAGE proximity detector. 275HP has eight voltage detection settings from 240Vac to 275KVac. & 500HP
has 10 Voltage detection settings from 240V to 500KV. The 275HP / 500HP consists of an internal pickup sensor plate, a sensitivity selector,
a visual and a sound annunciator. With the 275HP / 500HP physical contact with electrical conductors is not necessary when testing for live
lines. This tester works by proximity.
Its sensor senses the radiated field which surrounds live conductors. Radiated field strength increases with voltage & decreases quickly with
distance or earth shielding. The radiated field from a cable of closely bunched conductors supplied by three phase power tends to cancel
(See "Limitations of use" paragraph). Detecting distance of a 250Vac single live wire is approximately 10cm. With a bunched neutral and
earth cable, as in a flexible cable, the distance is reduced to 5cm.
Some of the typical users are : identify and check live cables; find fault in flexible cables; check earth equipment; service neon lightning;
trace live wires; check high frequency radiation ; detect residual or induced voltages. For example, faults in damaged flexible cables are
found by applying low voltage to each conductor. Earthing the remainder and moving the tester along the cable until the change in condition
is obtained. (Flexible cables which are used in mining and building industries, are readily repairable when the break in the cable is located.)
When using for high voltage, the rotary switch (attenuator) is used to identify and differentiate various HV live cables. The tester must be
used in conjunction with a long and insulating rod when measuring high voltage (KV). However, the 275 HP / 500HP is a non contact
tester and it is advised that the tester should never come in to contact with cables (KV) as this tester is merely a non-contact AC proximity
tester.
Checking or proofing the tester is easy. Switch the sensitivity to 240V AC and place the dome against a low voltage live conductor or rub the dome with a cloth or
against an item of clothing as this generates a static DC which triggers the detection of circuit. The light and beeper should go "on" as if a live wire is being approached.
Approaching the dome near a computer screen or a TV screen (not liquid crystal display type) should also trigger the tester while on 240V selection.
FEATURES :
8 Voltage Settings : 240V , 2KV, 6KV, 11KV, 22KV, 33KV, 132KV and 275KV AC (Model 275HP).
10 Voltage Settings : 240V, 3.3KV, 11KV, 22KV, 33KV, 66KV,110KV, 220KV, 330KV, 500KV (Model 500HP).
Self test selection.
High bright LEDs visual indication.
Sound indication.
SAFETY:
Meets EN61000-3-2; EN61000-3-3; EN61326-1; EN55011 EN61000-4-2; EN61000-4-3; EN61000-4-4; EN61000-4-5; EN61000-4-6; EN61000-4-11.
Typical observation of test
results made in the fields
MDV as % of
MinDetection
Range
Line Voltage
Voltage (MDV)
1KV
9.1%
11KV
9.1%
2KV
22KV
3.1KV
9.4%
33KV
12.5KV
9.5%
132KV
22.5KV
8.2%
275KV
LIMITATIONS OF USE :
It is recommended that the 275HP / 500HP is not used in HV yards of mixed voltages. In the presence of mixed voltages, the tester can become unreliable.
Problems can arise when the tertiary circuit of a 275/133/11KV transformer is tested. The electric field of the HV and MV bus bars can trigger the detector when it is
above 3m above the ground. This is common with most of the electric field voltage detectors, and the users should be aware of it. The tester can pick up adjacent
circuit to the one being tested and indicate the wrong information to the user.
"KUSAM-MECO" Hot Stick is suitable for use with Non Contact High Voltage Detector Model 275HP & 500HP. It's construction is Telescopic. It is constructed from
highly insulating reinforced Fibre Glass rod. The reinforcement gives high mechanical strength. It has a rubber gripper for holding it firmly when making
measurements of H.T. Lines. It is supplied with carry bag.
Model
HSR 120
1 x 1.2m Orange stick & 3 x 1.8m Black stick.
1 x 1.2m Orange stick
HSR 120A
1 x 1.8m Black stick
HSR 120B
HSR 120C
1 x 1.8m Black stick with handle
HSR 121
1 x 3.0m Retractable stick.
HSR 122
1 x 5.0m
®
An ISO 9001:2008 Company
Navin.com/D.drive/sandeep gupta/New catlog Dec 2011/
®
HIGH VOLTAGE PROXIMITY DETECTOR
Non-contact work by proximity.
Detect low voltage on any systems.
Compatible with most link sticks.
Expected test results
(laboratory testing):
Range
240V
Variable from 80V or depending on the type of source
2KV
6KV
11KV
22KV
33KV
132KV
HOT STICK
Model HSR - 120 / 120A / 120B / 120C / 121 / 122
Length
Retractable
stick.
G-17, Bharat Industrial Estate, T. J. Road, Sewree (W), Mumbai - 400 015. INDIA.
Sales Direct.: 022 -24156638,
Email : kusam_meco@vsnl.net,
275HP-
Model 275 HP (Upto 275KV) / 500 HP (Upto 500KV)
Use 3 x 1.5V "C" batteries
Easy access to batteries.
High impact nylon casing.
Operated From
250V
e.g. If the range selected is PC11KV, the minimum distance for
500V
detection of the PC11KV voltage is 22cm. But if the range
1000V
1500V
selected is PC22KV, you need to be closer (14cm) to detect
4000V
the PC11KV conductor.
8000V
Combination of 3 Models Sticks HSR 120A, 120B & 120C
All Specifications are subject to change without prior notice
Tel. : 022-241224540, 24181649,
500HP.cdr
Sealed by "0" rings
Suitable for indoor and outdoor use.
Light weight, robust, & compact.
Weight : Approx. 500g.
The distance for detection of the voltage depends upon the
range selected & actual Voltage of the conductor.
Fax : 022 - 24149659
Website : www.kusamelectrical.com

Advertisement

loading

Summary of Contents for Kusam-meco 275 HP

  • Page 1 When using for high voltage, the rotary switch (attenuator) is used to identify and differentiate various HV live cables. The tester must be used in conjunction with a long and insulating rod when measuring high voltage (KV). However, the 275 HP / 500HP is a non contact tester and it is advised that the tester should never come in to contact with cables (KV) as this tester is merely a non-contact AC proximity tester.
  • Page 2 HI - PROX 275HP - TEST REPORT NOTES - 1. The distance for 10cm at an angle of 90 . MEASURED 275HP V for Sound and Angle Distance Setting Light Trigger 240Vac 162Vac 10cm 1350Vac 10cm 10cm 4800Vac 11kV 10kV 10cm 22kV 10cm...
  • Page 3 4. The rotary setting selector is now positioned on the 2kV position. MEASURED Distance 275HP V on the Angle For Detection Setting generator 2kVac 1000Vac 10cm 2kVac 2000Vac 21cm 2kVac 6000Vac 40cm 2kVac 11000Vac 52cm 2kVac 22000Vac 60cm 2kVac 33000Vac 92cm The Higher the voltage, the smaller the distance of detection.
  • Page 4 7. The rotary setting selector is now positioned on the 22kV position. MEASURED Distance 275HP V on the Angle For Detection Setting generator 22kVac 3000Vac ---- 22kVac 4000Vac 22kVac 6000Vac 22kVac 11000Vac 14cm 22kVac 22000Vac 25cm 22kVac 33000Vac 36cm We increased the selection voltage to 22kV and now, you need to be closer to detect the 11kV conductor.
  • Page 5 WARRANTY An ISO 9001:2008 Company Each “KUSAM-MECO” product is warranted to be free from defects in material and workmanship under normal use & service. The warranty period is one year (12 months) and begins from the date of despatch of goods. In HIGH VOLTAGE A.C.
  • Page 6 ® ® INDEX Page Specifications Safety Rules..........03 Electrical Detecting Ranges General Description........Selection Detects voltage from 240V Variable from 80V Low Voltage Testing........or depending on type of source Front Panel Layout........06 250V 500V Preparation for Use ........07 11kV 1000V 22kV...
  • Page 7 ® ® Laboratory And Field Test Results Safety Rules Expected test results ( laboratory testing ) The 275HP Hi-Prox has been designed with safety in mind. Range Operated from However, no design can completely protect against 240V Variable from 80V incorrect use.
  • Page 8: General Description

    ® ® General Description High Voltage Testing The rotary switch (attenuator) is used to identify and The 275HP Hi-Prox consists of an internal pickup sensor differentiate various HV live cables. The tester must be plate, a rotary switch as sensitivity selector, a sound used in conjunction with a long and insulating rod when annunciator (high pitch, high power buzzer), a visual measuring high voltage (kV).
  • Page 9 ® ® Low Voltage Testing Typical Uses Identify and check live cables The 275HP Hi-Prox works by proximity. Physical contact Check and detect live high voltage cables (using with electrical conductors is not necessary when testing for extension hot stick) live lines.
  • Page 10: Front Panel Layout

    ® ® Front Panel Layout Preparation for Use - Turn the pick-up sensor off When unpacked, the tester should be inspected for any Self-Test - Check if the entire circuitry is working visible signs of damage, and the preliminary checks 240Vac - 240Vac selection described in the user manual should be performed to ensure...

This manual is also suitable for:

500 hp