Installation - Fisher EWS Series Instruction Manual

Through nps 12x8
Table of Contents

Advertisement

EW Valve
Valve Design
EWD
EWS
S
EWS
EWT with all except
p
Cavitrol III cages
EWT with
1-stage Cavitrol III cage
EWT with 2-stage Cavitrol III cage
1. Class V shutoff for Design EWT requires spring loaded seal ring, radius-seat plug, wide-bevel seat ring, and seat lapping. Not available with 8-inch port, quick-opening cage. Not
available with S31600 (316 SST) valve plug and seat ring.
Table 3. Additional Shutoff Classification for C-seal Trim Per ANSI/FCI 70-2 and IEC 60534-4
Valve
Valve Size, NPS
Design EWD
Design EWD
(CL300 CL600)
(CL300, CL600)

Installation

WARNING
Always wear protective gloves,
clothing, and eyewear when
performing any installation operations
to avoid personal injury.
Personal injury or equipment damage
caused by sudden release of pressure
or bursting of parts may result if the
valve assembly is installed where
service conditions could exceed the
limits given in table 1 or on the
appropriate nameplates. To avoid such
injury or damage, provide a relief valve
for overpressure protection as
required by government or accepted
industry codes and good engineering
practices.
Check with your process or safety
engineer for any additional measures
that must be taken to protect against
process media.
If installing into an existing
application, also refer to the WARNING
4
Table 2. Shutoff Classification Per ANSI/FCI 70-2 and IEC 60534-4
Seating
Metal
II (standard)
III (optional for NPS 6x4 through 12x6 valves with optional single graphite piston ring or for
NPS 10x8 and 12x8 valves with optional double piston rings)
IV (optional for NPS 6x4 through 12x8 valves with optional multiple graphite piston rings)
Metal
IV (standard)
V (optional, consult your Emerson Process Management sales office)
PTFE
VI
PTFE
Standard Air Test (maximum leakage is 0.05 mL/min/psid/inch port diameter)
V (optional)
Metal
IV (standard)
Metal
V (optional)
Metal
IV (standard)
V (optional)
Metal
V
Port Diameter, Inches
6x4x2.5
2.875
6x4
4.375
8x4
8x6 and 12x6
5.375
8x6
12x6
10x8
12x8
(1)
Equal Percentage, Linear, Whisper I,
Cavitrol III (2-stage)
Equal Percentage, Linear, Whisper I,
Cavitrol III (1-stage)
Whisper III (A3, B3, D3, D3), Cavitrol III (2-stage)
Equal Percentage, Linear, Whisper I,
7
Cavitrol III (1-stage)
Equal Percentage, Linear, Whisper I,
8
Cavitrol III (1-stage)
at the beginning of the Maintenance
section in this instruction manual.
When ordered, the valve configuration
and construction materials were
selected to meet particular pressure,
temperature, pressure drop and
controlled fluid conditions.
Responsibility for the safety of
process media and compatibility of
valve materials with process media
rests solely with the purchaser and
end-user. Since some body/trim
material combinations are limited in
their pressure drop and temperature
ranges, do not apply any other
conditions to the valve without first
contacting your Emerson Process
Management sales office.
Before installing the valve, inspect the
valve and pipelines for any damage
and any foreign material which may
cause product damage.
Instruction Manual
Shutoff Class
Cage Style
CAUTION
Form 2376
March 2007
Leakage Class
V (for port
diameters from 2.875
diameters from 2 875
through 8-inch with
through 8-inch with
optional C-seal trim)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ewd seriesEwt series

Table of Contents