Kenwood NX-200 Service Manual page 41

Vhf digital transceiver
Hide thumbs Also See for NX-200:
Table of Contents

Advertisement

• Analog mode signaling
No.
RX
1
None
2
None
LTR Data:
AREA=0, GOTO=12
3
HOME=12
ID=47, FREE=25
4
QT: 67.0Hz
5
QT: 151.4Hz
6
QT: 210.7Hz
7
QT: 254.1Hz
8
DQT: D023N
9
DQT: D754I
10
DTMF: 159D
11
None
2-tone:
12
A: 304.7Hz
B: 3106.0Hz
13
Single Tone: 979.9Hz
14
None
15
None
16
MSK
• NXDN mode signaling
No.
RX
1
RAN1
2
None
3
RAN1
7
None
9
Tone Pattern (1031Hz) Tone Pattern (1031Hz)
RAN: Radio Access Number
PN9: Pseudo-Random Pattern (for production only)
No.7,9 item: PC test mode only.
Panel Tuning Mode
■Transceiver tuning (To enter tuning mode)
To enter tuning mode, press the [ ] key while the trans-
ceiver is in test mode. Use the [ ] key to write tuning data
through tuning modes, and the [
requirements (1 to 4096 appears on the LCD).
Use the [
] key to select the adjustment item through
tuning modes. Use the [ ] key to adjust 5 reference level ad-
justments, and use the [Side2] key to switch between Wide/
Narrow/Very narrow.
ADJUSTMENT
TX
None
100Hz Square Wave
LTR Data:
AREA=0, GOTO=12
HOME=12
ID=47, FREE=25
QT: 67.0Hz
QT: 151.4Hz
QT: 210.7Hz
QT: 254.1Hz
DQT: D023N
DQT: D754I
DTMF: 159D
DTMF Code 9
2-tone:
A: 304.7Hz
B: 3106.0Hz
Single Tone: 979.9Hz
Single Tone: 1000Hz
MSK
MSK
TX
RAN1
PN9
Maximum deviation pattern
FSW+PN9
]/[
] key to adjust tuning
• LCD display in panel tuning mode
CV voltage, AD value, etc
2.6
Sub LCD display
An
Main LCD display
Adjustment
point
L,L',C,H',H
An: Analog narrow mode
Aw: Analog wide mode
Nn: NXDN narrow mode
Nv: NXDN very narrow mode
■ Key operation
Key
Push
[Selector]
[
]
Adjustment value up
[
]
Adjustment value down
[Side1]
Auto adjustment start
[Side2]
Wide/Narrow/Very narrow -
[ ]
Shift to panel test mode
To enter 5 reference level
[ ]
adjustments
Writes the adjustment
[ ]
value
Go to next adjustment
[
]
item
[Orange]
[PTT]
[0] to [9]
and
[#], [ ]
■ 5 reference level adjustments frequency
Tuning point
RX (MHz)
Low
136.05000
Low'
145.55000
Center
155.05000
High'
164.55000
High
173.95000
NX-200(G)
CNTR
256
Adjustment value
(1~4096)
Proper value guide
(When the frequency
adjustment is necessary,
▼ or ▲ is displayed.)
Adjustment item
Function
Hold (1 second)
-
Continuation up
Continuation down
-
-
-
-
Back to last adjustment
item
-
Transmit
-
TX (MHz)
136.10000
145.60000
155.10000
164.60000
173.90000
41