Volume measurement setting
Process Info
TAG
Calibration LRV 0%
Calibration URV 100%
Calibration Unit
PRTB_SECONDARY_VALUE_1_UNIT
Linearization Type
PRTB_LIN_TYPE
Output scale 0%
Output scale 100%
Output Scale Unit
Further common setting
Process Info
Node Address
Damping
Critical Limit Low
Advisory Limit Low
Advisory Limit High
Critical Limit High
Alarm Hysteresis
Fail Safe Type
No field calibration is normally requested, the transmitter has
been trimmed to the calibration points (URV and LRV) to
provide the best performances in the real operating range.
In case the calibrated range has to be changed, please refer to
the section 12 in this manual
Device parameter to be configured
PB_TAG_DESC
PRTB_SCALE_IN 0%
PRTB_SCALE_IN 100%
linearisation table
cylindrical lying container
spherical container
AI1_OUT_SCALE 0%
AI1_PV_SCALE 0%
PRTB_SCALE_OUT 0%
AI1_OUT_SCALE 100%
AI1_PV_SCALE 100%
PRTB_SCALE_OUT 100%
AI1_OUT_SCALE Unit Code
PRTB_PRIMARY_VALUE_UNIT
Device parameter to be configured
AI1_PV_FTIME
AI1_LO_LO_LIM
AI1_LO_LIM
AI1_HI_LIM
AI1_HI_HI_LIM
AI1_ALARM_HYS
AI1_FSAFE_TYPE
2600T Series Pressure transmitters | OI/266/PB-EN Rev. E 41
11 Commissioning