Neutralization; Use As A Relative Field-Strength Meter - Heathkit HD-1250 Manual

Solid-state dip meter
Table of Contents

Advertisement

Page
52
NEUTRALIZATION
1
.
Remove
the
final
voltage
from
the
transmitter.
2.
Apply power
to the
driver
stage.
3.
Use
the
Dip Meter
in
the absorption
mode.
4.
Couple
the dip meter
coil
to the
output
of the
stage
being
neutralized.
5.
Adjust the
Dip
Meter to the
driver
frequency
to obtain
a
maximum
meter
deflection.
6.
Adjust the
neutralizing capacitor for
a
minimum
meter
reading.
USE
AS
A
RELATIVE FIELD-STRENGTH
METER
Refer to Figure 3-5
for
the following
steps.
1.
Connect
a short
antenna around
the dip
meter pickup
coil
as
shown.
2.
Set the
Dip Meter
for use
in
the absorption
mode.
3.
Tune
the
Dip Meter
to
the resonant frequency of the
transmitter output.
4.
Position
the
pickup antenna
at
various points
around
the transmitting
antenna
to
determine
relative
strength.
Figure 3-5