PRESSURE MEASUREMENT
Always make the adjustments with the manometer in
place.
The main pressure is measured from the measuring
point in the control valve's inlet section.
Adjustments and inspections for each movement:
• Set the main pressure relief valve to 5 bar
above the value set for the protective valve.
• Perform the movement, and check and adjust
the pressure if necessary.
• Finish by adjusting the main pressure to the set
value.
Pressure measurements are to be performed at the
normal operating temperature and at the normal
flow rate.
The free flow pressure can be read from the ma-
nometer when the flow of oil is directed through
the valve.
REPAIR WELDING
If welding is required for modifying or repairing the
crane, note the following:
The welder must be qualified: welding grade 3. The-
re must be no root defects.
Remove paint and any oil from the location to be
welded.
Connect the ground terminal directly to the piece
to be welded – there must be no joints in between.
Use OK 48.00 or equivalent electrodes. The
electrodes must be dry.
Improperly welded structures can get fractured.
FARMI 4067
25