INSTALLATION

Warning:Before using this unit, please keep it upright for at least 3-4 hours.
This unit can easily be moved from one room to another.
While moving the unit please note that it must be kept upright and then placed on an even
surface.
3. Twist the hose connector into the exhaust outlet on the rear
of the unit.
INSTALLATION OF WINDOW KIT
2. Make sure the unit is upright and there are no obstructions
to the air inlet grills.
NOTES
:
To ensure efficient operation the opening should be as small as possible.
The best form of installation is through a wall duct.
The unit will need to be externally in heating mode (AC12HP only), ideally through the
wall. By properly venting you expel cold air from your room while efficiently heating it.
Your air conditioner should be used without a vent hose in dehumidifier mode. Please
ensure an external water tank is used, monitored and regularly emptied before over
spilling. Permanent plumbing can be also installed in dehumidifier mode, alternatively an
external water pump can be fitted for unattended use.
IMPORTANT SAFEGUARDS
The length of the soft hose extends from 28 cm to 150 cm. If the hose is extended above
this length the unit may malfunction and this can invalidate the warranty.
The outlet vent must be well ventilated and not obstructed as this will cause the unit to
overheat. Avoid bending the hose more than 30°.
1. Extend one end of the hose
and connect the hose
connector, by twisting it a
number of full rotations.
2. In the same way connect the
fishtail adapter to the opposite
end of the exhaust hose.
3. With the hose and
fishtail adaptor
connected to the
unit, push the end of
the fishtail adaptor
into the slot in the
slide bar.
6
The window kit (slide bar and fishtail)
can be used with sliding windows and
doors. For other types of window, the
fishtail should be used on its own.
1.
Partially open the window and then fix
the window kit to fill the opening in the
window.