Lowry LDH1001 Manual

Lowry LDH1001 Manual

10l dehumidifier 220-240v ac 50/60hz 290w

Advertisement

10L Dehumidifier
Model Number: LDH1001
220-240V AC 50/60Hz 290W
For Customer Services & Spare Parts please call 0345 209 7461
Opening times: Monday - Friday 8am – 8pm & Saturday 9am – 1pm
Or visit us at www.productcare.co.uk
PLEASE RETAIN
FOR FUTURE REFERENCE

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LDH1001 and is the answer not in the manual?

Questions and answers

Joyce Wilkinson
April 30, 2025

Where can I buy a castor for Lowry humidifier

User image 681246c7723bb

Summary of Contents for Lowry LDH1001

  • Page 1 10L Dehumidifier Model Number: LDH1001 220-240V AC 50/60Hz 290W For Customer Services & Spare Parts please call 0345 209 7461 Opening times: Monday - Friday 8am – 8pm & Saturday 9am – 1pm Or visit us at www.productcare.co.uk PLEASE RETAIN...
  • Page 2: Table Of Contents

    CONTENTS Page(s) Safety Instructions and Electrical Safety 3 - 4 Feature Diagram Control Panel Diagram Positioning your Dehumidifier Using your Dehumidifier 8 - 12 Emptying your Dehumidifier Cleaning and Care 14 - 15 Troubleshooting Guarantee and Customer Services Spare Parts Connection to the Mains Supply Notes Specification...
  • Page 3: Safety Instructions And Electrical Safety

    Safety Instructions Important note: Please read this booklet before installing and switching on this appliance. The manufacturer assumes no responsibility for incorrect installation and usage as described in this booklet. • This model uses natural refrigerant gas as part of its cooling system. This gas is known as R134a (tetrafluoroethane) and is environmentally friendly but can be combustible.
  • Page 4 Safety Instructions • Do not use in the following locations:- Next to a source of fire. An area where oil is likely to splash. An area exposed to direct sunlight. An area where water is likely to splash. Near a bath, shower or a swimming pool. In a greenhouse.
  • Page 5: Feature Diagram

    FEATURE DIAGRAM 5. Handle 1. Control panel 6. Air Outlet grille 2. Air intake grille 7 Power cord storage band 3. Water drawer 8. Drain hose outlet 4. Air filter (behind the air intake grille) For Customer Services & Spare Parts please call 0345 209 7461 Opening times: Monday - Friday 8am –...
  • Page 6: Control Panel Diagram

    CONTROL PANEL DIAGRAM 1. Power 2. Silent Mode 3. Water Drawer Full Indicator 4. Display 5. Up/Down Control Pads 6. Auto Defrost Indicator 7. Timer 8. Continuous Extraction For Customer Services & Spare Parts please call 0345 209 7461 Opening times: Monday - Friday 8am – 8pm & Saturday 9am – 1pm Or visit us at www.productcare.co.uk Page 6...
  • Page 7: Positioning Your Dehumidifier

    POSITIONING YOUR DEHUMIDIFIER • This dehumidifier is intended for indoor residential applications only. This dehumidifier should not be used for commercial or industrial applications. • Place the dehumidifier on a smooth, level floor strong enough to support the unit with a full drawer of water. •...
  • Page 8: Using Your Dehumidifier

    USING YOUR DEHUMIDIFIER When using the dehumidifier for the first time, run the unit in continuous mode for 24 hours Turning the Unit On Remove all packaging and plug the unit into a socket. Ensure the water drawer is correctly positioned, the drain plug is in place in the back of the unit if you are using the drawer to collect the water.
  • Page 9 USING YOUR DEHUMIDIFIER Silent Mode To reduce the noise output, for example, when being used at night, the silent mode can be activated. In this mode, the fan speed is slower and the unit will be running at a lower extraction rate. Press the Silent button.
  • Page 10 USING YOUR DEHUMIDIFIER Setting the Timer The Timer can be set for both Delayed Start and Auto Stop functions. Note: Turning the unit On or Off at any time will cancel the Delayed Start or Auto Stop functions and the unit can take 2 minutes to restart. If the water drawer is full or “P2”...
  • Page 11 USING YOUR DEHUMIDIFIER Other features Auto Shut Off The dehumidifier will shut off automatically under the following conditions: • When the water drawer is full • When the water drawer is removed • When the water drawer is not replaced in the proper position •...
  • Page 12: Using Your Dehumidifier

    USING YOUR DEHUMIDIFIER Error Codes P2 – Water drawer is full or drawer is not in the right position. Empty the drawer and replace in the correct position. AS - Humidity module sensor error. Unplug the unit and plug it back in. If error repeats, call customer service.
  • Page 13: Emptying Your Dehumidifier

    EMPTYING YOUR DEHUMIDIFIER There are two ways to remove collected water: Collection in the Water Drawer When the water drawer is full, the unit will automatically stop running, and the Full indicator light will flash red. Slowly pull out the drawer. Grip the left and right handles securely, and carefully pull out straight so water does not spill.
  • Page 14: Cleaning And Care

    CLEANING AND CARE Cleaning the Air Filter The air filter is located behind the front grille should be checked and cleaned at least every 30 days or more often if necessary. NOTE: DO NOT PUT THE FILTER IN AN AUTOMATIC DISHWASHER To Remove the Air Filter: Pull the water drawer out.
  • Page 15 CLEANING AND CARE Turn the dehumidifier off and remove the plug from the wall outlet before cleaning. Cleaning the Grille and Case Use water and a mild detergent. Do not use bleach or abrasives. Do not splash water directly onto the main unit. Doing so may cause an electrical shock, cause the insulation to deteriorate, or cause the unit to rust.
  • Page 16: Troubleshooting

    TROUBLE SHOOTING Problem What to check • Unit does not start Make sure the dehumidifier’s plug is pushed completely into the socket outlet. • Check the house fuse/circuit breaker box. • Dehumidifier has reached its preset level or drawer is full. •...
  • Page 17: Guarantee And Customer Services

    GUARANTEE AND CUSTOMER SERVICES At Lowry, we take all our customer feedback seriously. Feel free to contact our Product Care Team, on 0345 209 7461 Monday – Friday: 8am-8pm & Saturday: 9am – 1pm, who will be more than happy to assist you.
  • Page 18: Spare Parts

    SPARE PARTS To check the availability of the following spare parts, simply contact our friendly Customer Services team using the details provided at the bottom of this page. Air Filter Drain Hose Bung For Customer Services & Spare Parts please call 0345 209 7461 Opening times: Monday - Friday 8am –...
  • Page 19: Connection To The Mains Supply

    CONNECTION TO THE MAINS SUPPLY This appliance is designed to operate from a mains supply of 220-240V~ 50/60Hz. Check that the voltage marked on the product corresponds with your supply voltage. How to change the fuse 1. Slot the end of a screwdriver into the recess in the fuse holder of the plug.
  • Page 20: Notes

    NOTES Page 20...
  • Page 21: Specification

    Specification LDH1001 Model 220 – 240V 50Hz Voltage 290W Power Input 10L day (DB 30 C RH80%) Moisture Removal R134a/80g Refrigerant 24.7cm 30.8cm 45.6cm Overall Size (D x W x H) C - 35 Operating Temperature 11.2Kg Weight Page 21...