CONTENTS Page(s) Safety Instructions and Electrical Safety 3 - 4 Feature Diagram Control Panel Diagram Positioning your Dehumidifier Using your Dehumidifier 8 - 12 Emptying your Dehumidifier Cleaning and Care 14 - 15 Troubleshooting Guarantee and Customer Services Spare Parts Connection to the Mains Supply Notes Specification...
Safety Instructions Important note: Please read this booklet before installing and switching on this appliance. The manufacturer assumes no responsibility for incorrect installation and usage as described in this booklet. • This model uses natural refrigerant gas as part of its cooling system. This gas is known as R134a (tetrafluoroethane) and is environmentally friendly but can be combustible.
Page 4
Safety Instructions • Do not use in the following locations:- Next to a source of fire. An area where oil is likely to splash. An area exposed to direct sunlight. An area where water is likely to splash. Near a bath, shower or a swimming pool. In a greenhouse.
FEATURE DIAGRAM 5. Handle 1. Control panel 6. Air Outlet grille 2. Air intake grille 7 Power cord storage band 3. Water drawer 8. Drain hose outlet 4. Air filter (behind the air intake grille) For Customer Services & Spare Parts please call 0345 209 7461 Opening times: Monday - Friday 8am –...
POSITIONING YOUR DEHUMIDIFIER • This dehumidifier is intended for indoor residential applications only. This dehumidifier should not be used for commercial or industrial applications. • Place the dehumidifier on a smooth, level floor strong enough to support the unit with a full drawer of water. •...
USING YOUR DEHUMIDIFIER When using the dehumidifier for the first time, run the unit in continuous mode for 24 hours Turning the Unit On Remove all packaging and plug the unit into a socket. Ensure the water drawer is correctly positioned, the drain plug is in place in the back of the unit if you are using the drawer to collect the water.
Page 9
USING YOUR DEHUMIDIFIER Silent Mode To reduce the noise output, for example, when being used at night, the silent mode can be activated. In this mode, the fan speed is slower and the unit will be running at a lower extraction rate. Press the Silent button.
Page 10
USING YOUR DEHUMIDIFIER Setting the Timer The Timer can be set for both Delayed Start and Auto Stop functions. Note: Turning the unit On or Off at any time will cancel the Delayed Start or Auto Stop functions and the unit can take 2 minutes to restart. If the water drawer is full or “P2”...
Page 11
USING YOUR DEHUMIDIFIER Other features Auto Shut Off The dehumidifier will shut off automatically under the following conditions: • When the water drawer is full • When the water drawer is removed • When the water drawer is not replaced in the proper position •...
USING YOUR DEHUMIDIFIER Error Codes P2 – Water drawer is full or drawer is not in the right position. Empty the drawer and replace in the correct position. AS - Humidity module sensor error. Unplug the unit and plug it back in. If error repeats, call customer service.
EMPTYING YOUR DEHUMIDIFIER There are two ways to remove collected water: Collection in the Water Drawer When the water drawer is full, the unit will automatically stop running, and the Full indicator light will flash red. Slowly pull out the drawer. Grip the left and right handles securely, and carefully pull out straight so water does not spill.
CLEANING AND CARE Cleaning the Air Filter The air filter is located behind the front grille should be checked and cleaned at least every 30 days or more often if necessary. NOTE: DO NOT PUT THE FILTER IN AN AUTOMATIC DISHWASHER To Remove the Air Filter: Pull the water drawer out.
Page 15
CLEANING AND CARE Turn the dehumidifier off and remove the plug from the wall outlet before cleaning. Cleaning the Grille and Case Use water and a mild detergent. Do not use bleach or abrasives. Do not splash water directly onto the main unit. Doing so may cause an electrical shock, cause the insulation to deteriorate, or cause the unit to rust.
TROUBLE SHOOTING Problem What to check • Unit does not start Make sure the dehumidifier’s plug is pushed completely into the socket outlet. • Check the house fuse/circuit breaker box. • Dehumidifier has reached its preset level or drawer is full. •...
GUARANTEE AND CUSTOMER SERVICES At Lowry, we take all our customer feedback seriously. Feel free to contact our Product Care Team, on 0345 209 7461 Monday – Friday: 8am-8pm & Saturday: 9am – 1pm, who will be more than happy to assist you.
SPARE PARTS To check the availability of the following spare parts, simply contact our friendly Customer Services team using the details provided at the bottom of this page. Air Filter Drain Hose Bung For Customer Services & Spare Parts please call 0345 209 7461 Opening times: Monday - Friday 8am –...
CONNECTION TO THE MAINS SUPPLY This appliance is designed to operate from a mains supply of 220-240V~ 50/60Hz. Check that the voltage marked on the product corresponds with your supply voltage. How to change the fuse 1. Slot the end of a screwdriver into the recess in the fuse holder of the plug.
Specification LDH1001 Model 220 – 240V 50Hz Voltage 290W Power Input 10L day (DB 30 C RH80%) Moisture Removal R134a/80g Refrigerant 24.7cm 30.8cm 45.6cm Overall Size (D x W x H) C - 35 Operating Temperature 11.2Kg Weight Page 21...
Page 22
Opening times: Monday - Friday 8am – 8pm & Saturday 9am –1pm Or visit us at www.productcare.co.uk Revision 2 Model: LDH1001 Made by G2S Ltd under license. G2S Limited, Wigan, WN2 4AY This symbol is known as the 'Crossed-out wheelie bin Symbol'.
Need help?
Do you have a question about the LDH1001 and is the answer not in the manual?
Questions and answers
Where can I buy a castor for Lowry humidifier