Quick-Start Guide - CDI EMS 4 User Manual

Remote display
Table of Contents

Advertisement

Quick-Start Guide

The following instructions will demonstrate how to operate the Remote Display with one
Digimatic indicator and one quadrature Probe.
1.
Plug in the supplied power adapter to the Remote Display Mux Box (item 5 on page 4).
The red LED on the rear panel will light up.
2.
Power up the supplied Android tablet. Press and hold the On Button (approx. 5 seconds)
until HP logo appears on screen and then release the On button. The display will take
approx. 30 seconds to startup. Using the supplied USB Micro to USB Type-A cable (item
1 on page 4, Back Panel), connect the Android tablet to the Remote Display Mux Box.
Do not connect the tablet to the USB Type-B connector, as this will not function properly!
3.
The Remote Display application should automatically start on the Android tablet. If it
does not start, unplug the tablet from the gage, wait a few seconds, and then
reconnect.
4.
Plug a quadrature probe into channel 1
The Android application defaults all channels to quadrature mode, so the gage
should start reporting counts immediately after connecting. Confirm this by moving
the spindle of the probe.
5.
Plug the device (with Digimatic output) into channel 2.
To configure channel 2 for Digimatic communication mode, long-press on the CH 02.
Channel 2 Properties page will appear on the tablet. Scroll down to the setting for "Gage
Type," then make sure Digimatic is selected. Press the back button on the tablet to return
to the main display.
6.
For all Digimatic devices, data can be manually requested by pressing the "Request"
button for the associated channel. Alternatively, data can be automatically updated at
constant intervals using the Auto Request and Logging feature. To set an automatic
update interval ( the Remote Display will not update the Digimatic Data unless
requested):
a. Long-press on the appropriate channel (CH 01, CH 02, CH 03, or CH 04)
b. Scroll down to the options titled "Auto Request and Logging / Automatic Request,
and Request Interval"
c. Select "Automatic Request" and the desired Request Interval rate (fastest
rates may not be supported by all devices)
Note that the "Request" button will no longer be visible for that channel. It is not
possible to manually request while the automatic function is active.