Diaphragm Monitoring (Option Code Dm1, Dm2); Flange Connections (Option Code F1, F2, F3, F4, F7, F8, F9) - Dellmeco DM 08/10 Instruction Manual

Air operated double diaphragm pumps
Hide thumbs Also See for DM 08/10:
Table of Contents

Advertisement

16.3. Diaphragm Monitoring (option code DM1, DM2)

Although DELLMECO diaphragms with integrated metal core are designed for an optimum service life, the
diaphragm remains a wear part. If it breaks, liquid can leak into the center housing and possibly emerge through the
muffler. This can be prevented simply and effectively with the DELLMECO diaphragm monitoring.
A capacitive diaphragm sensor is mounted in the muffler [17] of the pump, which registers any liquid approaching
the sensor, no matter whether the liquid is conductive or not. Hence, a fast reaction to a damage of a diaphragm
becomes possible. In case of humid surrounding air a false alert may occur despite operating the pump with dried
compressed air.
The diaphragm monitoring system is available in two variations:
• DM1 Diaphragm sensor (NAMUR), also for explosion-proof area
• DM2 Diaphragm monitoring system complete with sensor and controller
The diaphragm sensor can either be connected to an existing controller with NAMUR inlet (code DM1) or to the
controller included (code DM2). The wiring diagram and technical data can be found on the controller itself. For further
details, please refer to the data delivered by the manufacturers of the components. The controllers have to be installed
in a suitable cabinet.
Spare part list, diaphragm monitoring
Code
Position
Quantity
DM 1
63
1
63
1
DM 2
-
1

16.4. Flange Connections (option code F1, F2, F3, F4, F7, F8, F9)

This version offers the possibility to use flange connectors according to: DIN/PN10 (options: F1, F2, F3), JIS 5K
(option F4), PN10 DIN 2576 (option F7), ANSI 150 RF-SO (option F8), or PN16 DIN 2277/2278 (option F9). For
options: F1, F2, F3 thread bushings, made of stainless steel to fix the flanges, are included in the inlet/outlet discharge.
The O-rings attached have to be inserted into the grooves of the manifolds to improve sealing before connecting the
pump.
Spare part list, flange connection
Code
Pos.
Quantity
-
2
F1
-
8
-
2
F2
-
2
F3
-
2
-
2
F4
-
2
F7
-
2
F8
-
2
F9
-
2
Description
Diaphragm sensor, NAMUR
Diaphragm sensor, NAMUR
Controller
Description
DIN/PN10 flange connection
Flange thread bushing
Flange o-ring
as F1, but:
Flange o-ring
as F1, but:
Flange o-ring
Flange pipe
JIS 5K flange collar
as F4, but:
PN10/DIN 2576 flange collar
as F7, but:
ANSI 150 RF-SO flange collar
as F7, but:
PN16 DIN 2277/2278 flange collar
Pump size:
DM 10
Material
Part no.
diverse
9 15 19 00
diverse
9 15 19 00
diverse
9 15 14 00
Pump size:
DM 15
Material
Part no.
PE
2 15 25 20
PTFE
2 15 25 23
PE conductive
2 15 25 21
PTFE conductive
2 15 25 24
AISI 304
9 15 47 50
EPDM
2 15 78 08
NBR
2 15 78 10
FEP/FKM
2 15 78 04
PE
2 15 125 20
PTFE
2 15 125 23
PE conductive
2 15 125 21
PTFE conductive
2 15 125 24
PE
2 15 525 20
PE conductive
2 15 525 21
PE
2 15 225 20
PE conductive
2 15 225 21
PE
2 15 325 20
PE conductive
2 15 325 21
PE
2 15 425 20
PE conductive
2 15 425 21
DM 15
DM 25
DM 40
Part no.
Part no.
Part no.
9 15 19 00
9 15 19 00
9 15 19 00
9 15 19 00
9 15 19 00
9 15 19 00
9 15 14 00
9 15 14 00
9 15 14 00
DM 25
DM 40
Part no.
Part no.
2 25 25 20
2 40 25 20
2 25 25 23
2 40 25 23
2 25 25 21
2 40 25 21
2 25 25 24
2 40 25 24
9 15 47 50
9 40 47 50
2 25 78 08
2 40 78 08
2 25 78 10
2 40 78 10
2 25 78 04
2 40 78 04
2 25 125 20
2 40 125 20
2 25 125 23
2 40 125 23
2 25 125 21
2 40 125 21
2 25 125 24
2 40 125 24
2 25 525 20
2 40 525 20
2 25 525 21
2 40 525 21
2 25 225 20
2 40 225 20
2 25 225 21
2 40 225 21
2 25 325 20
2 40 325 20
2 25 325 21
2 40 325 21
2 25 425 20
2 40 425 20
2 25 425 21
2 40 425 21
35I DELLMECO I AODD DIAPHRAGM PUMPS
DM 50
Part no.
9 15 19 00
9 15 19 00
9 15 14 00
DM 50
Part no.
2 50 25 20
2 50 25 23
2 50 25 21
2 50 25 24
9 40 47 50
2 50 78 08
2 50 78 10
2 50 78 04
2 50 125 20
2 50 125 23
2 50 125 21
2 50 125 24
2 50 525 20
2 50 525 21
2 50 225 20
2 50 225 21
2 50 325 20
2 50 325 21
2 50 425 20
2 50 425 21

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dm 15/55Dm 25/125Dm 10/25Dm 40/315Dm 50/565Dm 80/850

Table of Contents