Download Print this page

Rear Panel Interface Operation - Fiilex Matrix II Turnable White User Manual

Advertisement

Rear Panel Interface Operation

Assigning DMX Address:
DMX Address Setting Screen
Main Screen with DMX Mode Active
Connect AC Power Adapter to AC Cable
Pull
Knob
CCT
PWR
HUE
DMX
1. Double click the DMX Address Dial (10) to unlock the DMX address
setting screen on the OLED Display (9).
2. Rotate the knob to select the desired base address (1-510).
3. Lock in setting by clicking knob once. Alternatively, the address will
automatically lock in after 1 second of inactivity.
4. When a DMX address is selected, the Matrix II Tunable White will
automatically assign the next two addresses in the following order:
(1) Intensity (2) CCT (3) Hue
• For adjusting fixture's DMX address via RDM, consult operating instruc-
tions for DMX/RDM control system.
AC Cable (Plug head varies by region: EU, UK, AU, ZA, CH)
lock
unlock
powerCON TRUE1
P/N: 5048669-001 (female)
5048669-002 (male)
Function
Set color temperature
Set intensity
Set HUE value
Set DMX address
(For regions outside of the U.S)
XLR 3-Pin Connector (DC out)
P/N: 5048659-001 (female)
Range
2800K - 6500K
100% - 0.1%
± 0.25 Magenta/Green
1 - 510
320W/48V Power Adapter

Advertisement

loading

This manual is also suitable for:

Flxmxg2