Page 1
Installation, Operation and Maintenance Manual Steambath Generator Systems Residential Models: MX4E, MX5E, MX6E ____________________ ____________________ IMPORTANT: Leave this material with the home owner. steam ® Feel Good Inc. ®...
Installation, Operation and Maintenance Manual SERIAL NO. __________________________ MODELS: MX4E, MX5E, MX6E INSTALLER'S SECTION: Important Safety Information .....1-2 PRE-INSTALLATION INFORMATION Steam Room Guidelines .
mr . steam ® Installation, Operation & Maintenance Manual __________________________________________________________________________ I N S T A L L E R S E C T I O N IMPORTANT SAFETY INFORMATION As you follow these instructions, you will notice warning and Indicates a potentially hazardous situation, which, caution symbols.
Page 4
mr . steam ® Installation, Operation & Maintenance Manual __________________________________________________________________________ IMPORTANT SAFETY INFORMATION (cont.) Applies to 1-6 1. This document contains important safety, operation 4. If acrylic, fiberglass or other non-heat resistant materials and maintenance information. Leave this document are used as part of the steam room enclosure, consult with the homeowner.
mr . steam ® Installation, Operation & Maintenance Manual __________________________________________________________________________ PRE-INSTALLATION CONSIDERATIONS STEAM ROOM GUIDELINES 4. The ceiling should be sloped and constructed to pre- To prevent slip and fall hazards non-skip strips vent dripping of condensate. must be installed on the steam room floor. 5.
mr . steam ® Installation, Operation & Maintenance Manual __________________________________________________________________________ STEAM GENERATOR LOCATING THE STEAM GENERATOR Applies to 1-6 Applies to 12-18 1. Do not route iSteam, AirTempo, iTempo/Plus, iTempo OR 12. Provide a minimum of (18) inches on the left side and HomeWizard control wiring inside conduit together with 21"...
mr . steam ® Installation, Operation & Maintenance Manual __________________________________________________________________________ STEAM GENERATOR CLEARANCE SPECIFICATIONS Applies to 1-2 1. Do not install MAX series inside a vanity or other small enclosed spaces. Do not install under the steam room bench. Installing the MAX steam generator in a small enclosed space may result in elevated temperatures and an inoperable steam generator.
All Models 29201CMS Heating Element 20 KW 240V MX4E MSTS Remote Temperature Probe All Models 29241BMS Heating Element 24 KW 208V MX5E for iTempo/Plus and AirTempo 29241CMS Heating Element 24 KW 240V MX5E 99012 Contactor 50A 3-pole All 3-Phase 29301BMS...
mr . steam ® Installation, Operation & Maintenance Manual _________________________________________________________________________ PLUMBING GENERAL DRAIN (cont.) Applies to 5-8 1. All plumbing shall be performed by a qualified licensed 5. A drain valve is provided to facilitate plumber and in accordance with applicable National and local maintenance and servicing.
Ampere Chart. If allowed by codes, NM cable may require a larger wire size than as listed on the chart. ____________________________________________ ______________________________________ 6. Connect suitably sized equipment grounding wire to MX5E 1075 ground terminal provided. Neutral (white) wire is not required for 208V and 240V units.
mr . steam ® Installation, Operation & Maintenance Manual __________________________________________________________________________ CONNECTING MULTIPLE GENERATORS IN TANDEM Applies to 1-2 1. Install each unit as in a single installation. Install the two generators as close to each other as possible, while providing for all clearances as shown on page 6. 2.
mr . steam ® Installation, Operation & Maintenance Manual __________________________________________________________________________ POST INSTALLATION STEAM GENERATOR SYSTEM START-UP AND CHECKOUT 1. Turn the control ON. Follow specific instructions provid- 3. Steam will shut OFF when control counts down to zero. To shut steam ed with the controls.
mr . steam ® Installation, Operation & Maintenance Manual __________________________________________________________________________ CONTROL STATUS CODES The control (either iSteam ® , AirTempo ® , iTempo or iTempo/Plus ) may display a status code if the steam generator ® ® is not functioning properly. Code Code Meaning Probable Cause...
A S S E S S O R I E S CONTROL INSTALLATION Refer to Installation Instructions for the specific control Applies to 1-5 Applies to 6-7 1. A peel and stick warning sticker must be read and per- 6. To avoid unintentional steambath operation, do not locate the con- manently affixed in a conspicuous location near the trol where other controls, accessories, shower heads, valves, body steam room.
mr . steam ® Installation, Operation & Maintenance Manual __________________________________________________________________________ ® Steam Generator OPTIONAL AUTOFLUSH 3 Pin Connector OPERATION for AutoFlush The optional AutoFlush System feature automatically drains the MrSteam generator following each use. A time delay allows the water to cool down (about two hours) before it drains by gravity for a safe and gentle operation.
mr . steam ® Installation, Operation & Maintenance Manual __________________________________________________________________________ OPTIONAL CONDENSATION PAN Applies to 1-7 1. MrSteam strongly recommends the use of a condensation pan in the unlikely event of a plumbing leak. 2. Locate the condensation pan on a solid level surface and place the steam generator inside the condensation pan.
mr . steam ® Installation, Operation & Maintenance Manual __________________________________________________________________________ H O M E O W N E R S E C T I O N IMPORTANT SAFETY INFORMATION As you follow these instructions, you will notice warning and caution symbols. This blocked information is important for the safe and efficient installation and operation of this generator.
mr . steam ® Installation, Operation & Maintenance Manual __________________________________________________________________________ IMPORTANT SAFETY INFORMATION (cont.) (cont.) The peel and stick warning label located in 21. If acrylic, fiberglass or other non-heat resistant materials are this manual is an essential part of providing a safe environ- used as part of the steam room enclosure consult with the ment for steam room users.
mr . steam ® Installation, Operation & Maintenance Manual __________________________________________________________________________ CARE TIPS FOR ALL CONTROLS STEAM GENERATOR MAINTENANCE AND STEAMHEADS MrSteam steambath generators require little maintenance. Other than periodic draining, maintenance procedures are minimal. Every 2 1. Use only mild soap and water on a soft cloth to clean the control and steamhead.
Page 25
steam ® Feel Good Inc. ® www.mrsteam.com Products, information and specifications are subject to change without notice. Please call Sales & Support at 1.800.76.STEAM (East Coast) or 1.800.72.STEAM (West Coast) for more information. steam ® Sussman-Automatic Corporation ® I hello@mrsteam.com I www.mrsteam.com 43-20 34th Street, Long Island City, NY 11101 : 1 800 76 STEAM I 9410 S.
Need help?
Do you have a question about the MX5E and is the answer not in the manual?
Questions and answers