Gas warning device EASYCON GW Operating instructions Table of Contents 1 Notes for the Reader ............4 8 Commissioning ..............18 1.1 General non-discrimination ............8.1 First steps ................1.2 Explanation of the signal words ..........8.2 Configuration ................. 1.3 Explanation of the warning signs ..........
Gas warning device EASYCON GW Operating instructions 1 Notes for the Reader 1.3 Explanation of the warning signs This operating manual contains information and behaviour rules for the safe and designated operation of the device. Warning signs represent the type and source of a danger:...
Gas warning device EASYCON GW Operating instructions 2 Safety 2.1 General warnings 2.2 Hazards due to non-compliance with the safety instructions The following warnings are intended to help you eliminate the dangers Failure to follow the safety instructions may endanger not only persons, that can arise while handling the device.
Page 6
Gas warning device EASYCON GW Operating instructions They are specially trained for their specific working environment and are familiar with relevant standards and provisions. They must comply with the legally binding regulations on accident pre- vention. 2.4.3 Trained persons Trained persons have received training from the operator about the tasks they are to perform and about the dangers stemming from improper be- haviour.
Gas warning device EASYCON GW Operating instructions 3 Intended use 3.3.3 Incorrect operation 3.1 Notes on product warranty Protective equipment not functioning correctly or dismantled. Any non-designated use of the device can impair its function and the pro- Unauthorised modification of the gas warning unit.
Gas warning device EASYCON GW Operating instructions 4 Product description 4.1 Scope of delivery Please compare the delivery note with the scope of delivery. The follow- ing items are part of the scope of delivery: Gas warning device Up to 4 sensors Operating instructions 4.2 Design and function...
P/N: *102A12345678* S/N: XXXXXXXXXX Made in *12345678012345* Germany Fig. 2: Main view with two sensors Fig. 3: Rating plate EASYCON GW Function Description Login / password settings Product name Date / time Electrical specifications / protection class Values / limit values...
Gas warning device EASYCON GW Operating instructions 5 Technical data 5.1 EASYCON GW Information Value Voltage supply 100 - 240 V AC, 50 / 60 Hz Power consumption max. 20 W Housing dimensions 302 x 240 x 107 mm Temperature sensor -10 ...
Gas warning device EASYCON GW Operating instructions 7 Installation 7.3 Electrical installation DANGER The voltage supply to your device can now be performed via a normal Mortal danger from electric shock! Schuko plug or a control cabinet. Perform the specifications of this sec- tion for devices without a pre-fitted Schuko plug.
Gas warning device EASYCON GW Operating instructions 7.5 Connecting the sensor 5. Open the device housing and lead the cable into the inside of the housing through one of the cable screw connections on the under- You can connect up to four sensors to the gas warning system. You can side of the housing.
79831_1 Gas warning device EASYCON GW Operating instructions 7.6 Connecting the signal technology 7.6.2 Output circuit board (relay) You can control the signal technology (e.g. bugles or signal lamps) with Depending on the equipment of the device, you have up to three different the relay output circuit boards.
Gas warning device EASYCON GW Operating instructions 7.7 Digital inputs 7.6.3 Output circuit board (optocoupler) The output circuit boards can optionally be fitted with optocouplers. Opto- You can use up to 8 digital inputs to evaluate switching statuses and to coupler circuit boards serve the output of a digital signal , e.g.
Gas warning device EASYCON GW Operating instructions 7.9 Connecting Ethernet You can use the Ethernet connection for the following actions: Reading/writing via Modbus TCP/IP protocol (PLC or Computer) Access via web browser Access via TFTP server The device has a network input in the form of a M12x1 socket. Lutz-Jes- co GmbH offers different lengths of special twisted-pair network cables to make the typical Ethernet RJ-45 plug connection.
Gas warning device EASYCON GW Operating instructions 8 Commissioning 8.2.1.1 Sensors 8.1 First steps The sensors must be configured individually in the device to enable pre- You need to make a number of basic settings before operating the device. cise and error-free measurement of the gases. You can perform various This section leads you through initial commissioning.
Page 19
Gas warning device EASYCON GW Operating instructions 4. Action: Choose between “OK = open” (N.O., working contact) or “OK 8.2.2.3 Digital output signals = contact” (N.C., break contact). You can control the connected signal technology with digital output sig- Configuration of the digital inputs completed.
Gas warning device EASYCON GW Operating instructions 8.2.3 Colours of the alarm messages Configuring the password protection You can edit the colours of the different messages. Perform the following steps: 1. In the main menu under System > Settings, navigate to the “Alarm colour”...
Gas warning device EASYCON GW Operating instructions 9 Operation Web browser When in operation, the device will display the main view with the current values and the status row with status messages. You can access the device data using all network devices which are fitted with a web browser.
10 Maintenance 6. Press the sensor element into the sensor bracket without force. At Products by Lutz-Jesco are manufactured to the highest quality stand- ards and have a long service life. However, some parts are subject to op- the same time, turn the sensor element until the plastic parts fit in erational wear.
Gas warning device EASYCON GW Operating instructions 10.5 Replacing the fuse 3. Confirm with “Yes”. The configuration will be deleted. You must proceed with the follow- ing section. Your device is fitted with an electrical fuse to protect against short circuits or over-voltage.
Gas warning device EASYCON GW Operating instructions 11 Troubleshooting See below for information about how to rectify faults on the device or the system. If you cannot eliminate the fault, please consult with the manufacturer on further measures or return the device for repair.
Gas warning device EASYCON GW Operating instructions 12 Modbus addresses With a DOUBLE-WORD, the HIGH-WORD is transferred first! Hexadecimal display is shown by a leading “0x”. Address Description Meaning Data that are not channel-related. Device type + version 0x0550 + (number of channels -1)
Page 26
Gas warning device EASYCON GW Operating instructions Address Description Meaning Channel-related data. 20 addresses are reserved for every channel. Start at 2020, 2040, 2060 and 2080. 2020 Medium 3) Chlorine gas 5) Chlorine dioxide 9) Ozone 15) Temperature 16) Neutral (0 - 100%)
Page 27
Gas warning device EASYCON GW Operating instructions Address Description Meaning Further non channel-related data. 2220 - 2223 Analogue outputs 1 - 4 421 = 4.21 mA 2225 Alarm status 1 Bit 0 ... 15 The bits are logically transferred: „15, 14 ... 1, 0“...
Gas warning device EASYCON GW Operating instructions 13 EU Declaration of Conformity (DE) EU-Konformitätserklärung Hiermit erklären wir, dass das nachfolgend bezeichnete Gerät aufgrund seiner Konzipierung und Bauart sowie in der von uns in Verkehr gebrachten Ausführung den einschlägigen grundlegenden Sicherheits- und Gesundheitsanforderungen der aufgeführten EU-Richtlinien entspricht. Bei einer nicht mit uns abgestimmten Änderung am Gerät verliert diese Erklärung ihre Gültigkeit.
Gas warning device EASYCON GW Operating instructions 14 Warranty claim Warranty claim Please copy and send it back with the unit! If the device breaks down within the period of warranty, please return it in a cleaned condition with the complete warranty claim.