Download Print this page
Little Giant APCP-1700 Manual

Little Giant APCP-1700 Manual

Pool cover pump
Hide thumbs Also See for APCP-1700:

Advertisement

Quick Links

Franklin Electric Co., Inc.
P . O. Box 12010
Oklahoma City, OK 73157-2010
Phone: 405-947-2511 • Fax: 405-947-8720
www.LittleGiantPump.com
CustomerService-WTS@fele.com
ENGLISH
EN
This instruction sheet provides you with the information required to
safely own and operate your product. Retain these instructions for
future reference.
The product you have purchased is of the highest quality workman-
ship and material, and has been engineered to give you long and
reliable service. This product has been carefully tested, inspected,
and packaged to ensure safe delivery and operation. Please exam-
ine your item(s) carefully to ensure that no damage occurred dur-
ing shipment. If damage has occurred, please contact the place of
purchase. They will assist you in replacement or repair, if required.
READ
THESE
INSTRUCTIONS
ATTEMPTING
TO
INSTALL,
YOUR PRODUCT. KNOW THE PRODUCT'S APPLICATION,
LIMITATIONS,
AND
POTENTIAL
YOURSELF AND OTHERS BY OBSERVING ALL SAFETY
INFORMATION.
FAILURE
INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/
OR PROPERTY DAMAGE!
SAFETY GUIDELINES
WARNING: To reduce the risk of injury, do not permit children to
use this product unless they are closely supervised at all times.
WARNING: Risk of electric shock. Connect only to a grounding
type receptacle protected by a ground-fault circuit interrupter
(GFCI). Contact a qualified electrician if you cannot verify that the
receptacle is protected by a GFCI.
WARNING: Do not bury cord. Locate cord to minimize damage
from lawn mowers, hedge trimmers, and other equipment.
WARNING: To reduce the risk of electric shock, replace damaged
cord immediately. Contact the manufacturer for replacement of
the power cord.
WARNING: To reduce the risk of electric shock, do not use exten-
sion cord to connect pump to electric supply; provide a properly
located outlet.
Never pump chemicals or corrosive liquids with this pump. This
could damage the integrity of the enclosure and cause an electrical
short. This pump has been evaluated for use with water only.
Never pump gasoline or other low flash point fluids with this pump.
Explosion or fire could result. This pump has been evaluated for
use with water only.
Do not run this pump dry. Running this pump without water may
damage the integrity of the enclosures and cause electrical short.
If service is required, proceed carefully. The pump and surrounding
areas may be covered with water. Never plug or unplug the device
while standing in wet or damp surfaces. If necessary, remove
power at the breaker panel or have certified electrician remove
power before attempting to service. Serious or fatal shocks could
result if proper procedures are not followed. Disconnect the power
at the main electrical service box by switching the appropriate
circuit breaker or removing fuse. In applications where screw type
fuses are used, remove only the one hand while other hand or torso
APCP-1700
POOL COVER
PUMP
CAREFULLY
BEFORE
OPERATE,
OR
SERVICE
HAZARDS.
PROTECT
TO
COMPLY
WITH
THESE
is free from contact with anything. Do not stand in water or do not
touch any other conductive surfaces.
Remove pump when conditions will cause water to freeze. Freezing
water may result in rupture to pump and/or switch enclosure and
could result in possible electrical short.
PUMP SPECIFICATIONS
VOLTS AMPS WATTS
1'
115
2.2
270
1700
CAPACITY SIZING INFORMATION
The 1700 GPH performance was obtained through a 1 inch I.D.
tube, with friction losses neglected. Using a 3/4" garden hose 50
foot long reduces this performance to approximately 500 gallons
per hour due to friction losses in the hose. If your area frequently
has heavy rainfalls, (1" - 2" per hour), it may be necessary to use 1"
tubing. This should be available in most pool supply stores.
The number of gallons of water that your pool will collect in a rainfall
of one inch per hour can be computed as follows: Cover overall
length (ft.) x cover overall width (ft.) x .6234 = gallons per hour.
NOTE: This is cover dimension, and not pool dimension.
Examples:
A 16' x 32' pool cover would collect 319 gallons (16 x 32 x
.6234 = 319) in 1 hour, in 1" per hour rain.
A 20' x 40' pool cover would collect 499 gallons (20 x 40 x
.6234 = 499) in 1 hour, in 1" per hour rain.
INSTALLATION
1. Verify that the electrical outlet to be used meets the require-
ments of the National Electrical Code (NEC), as well as local
electrical codes including grounding and GFCI protection. Also
verify that the outlet is properly sized and located for this pump.
Your installation may require a certified electrician or plumber.
See the ELECTRICAL CONNECTIONS section.
2. If necessary, check your plumbing codes to verify that final
installation will be in compliance with their requirements.
3. Connect a garden hose to the hose adaptor, or use a 1"
nipple and flexible PVC tubing secured to the pump discharge.
NOTE: If flexible 1" PVC tubing is used, secure the free end so
that it cannot blow back onto the pool cover in high wind.
4. Gently lower the pump onto the pool cover by holding onto
the garden hose. Do not pull the power cord plug onto the
pool cover. The pump is equipped with an eyelet opposite the
discharge for attaching a positioning rope (not included). Use
rope and a garden hose to position pump onto the pool cover.
Two people should position the pump, with the first person hold-
ing the electrical cord plug and the second person positioning
the pump at the desired location on the pool cover. The pump
is equipped with an 18 AWG, 25-foot power cord with a 3-prong
,grounding-type plug.
5. Once the pump is in position and proper electrical connections
have been made, it is ready for testing. See the ELECTRICAL
CONNECTIONS section.
During the rainy season, check daily to ensure that the pump is
functioning properly. During high winds or excessive movement of
the pool cover, be certain that the power supply cord has not been
pulled onto the cover, and that the pump is still upright with the dis-
charge hose properly positioned. If you plan to be away from your
pool for an extended period, have someone periodically check your
pump to verify that everything is functioning properly. Be sure to
review the SAFETY GUIDELINES and ELECTRICAL CONNECTIONS
sections with them.
GALLONS PER HOUR
5'
10'
15'
20'
21.5'
1500
1150
700
200
0
1

Advertisement

loading

Summary of Contents for Little Giant APCP-1700

  • Page 1 Do not stand in water or do not touch any other conductive surfaces. APCP-1700 Remove pump when conditions will cause water to freeze. Freezing water may result in rupture to pump and/or switch enclosure and POOL COVER Franklin Electric Co., Inc.
  • Page 2 OPERATION SERVICE INSTRUCTIONS The water level switch is activated by a float mechanism. This is WARNING: Before servicing pump, disconnect it from electrical caused by water rising around the float with the pump resting service, unplug cord, remove fuse, or turn off disconnect box. upright.
  • Page 3: Replacement Parts

    REPLACEMENT PARTS Item Part Description Qty. 177343 Garden hose adapter 177344 Float/stem assembly 177345 Float access cover FIGURE 2 TROUBLESHOOTING INFORMATION SYMPTOM CAUSE REMEDY Stuck float. Clean area around float. Defective switch. Contact factory. Pump will not shut Shut power off for approximately 1 minute, then restart. Repeat several times to clear Pump is air locked.
  • Page 4 36 months from date of purchase by the user. Any product that should fail for either of the above two reasons and is still within the warranty period will be repaired or replaced at the option of Little Giant as the sole remedy of buyer. For our custom- ers in the CONTINENTAL UNITED STATES: Please return the defective unit, postage paid, to the factory at 301 N.