The Elite 8D has 5 separate programmable monitored analogue inputs,
4 x
Programmable, multi-state detection inputs
1 x
Programmable tamper input ( with optional Key-switch functions)
Each input must be terminated with the appropriate value or combination of end-of-line resistors,
ZONE INPUTS - Each of the 4 zone inputs can be assigned one of the following configuration options;
Type 1(4Z)
Type 2(4Z)
Type 3(8Z)
Type 4(8Z)
The following table shows end-of-line resistor configurations. The reference to LEDS in bold below relate to the
program option setting at address P130E.
Zone
Type
Type 1(4 Zone)
LEDS 1-4 off, 5-8 off
Type 2(4 Zone)
LEDS 1-4 on, 5-8 off
Type 3(8 Zone)
LEDS 1-4 off, 5-8 on
Type 4(8 Zone)
LEDS 1-4 on, 5-8 on
Type 1 (4 Zones,Short Circuit)
Type 3 (8 Zones, 4k7 & 8k2 EOL with NO tamper)
Alarm Contact
n/c or n/o
4k7
Type 4 (8 Zones, 4k7 & 8k2 EOL with 2k2 EOL for tamper)
Alarm Contact
n/c or n/o
4k7
even if the input is unused.
4 Zone Short circuit input No-End-of-Line (EOL).
4 Zone Single-End-of-Line 2k2 (EOL) with no tamper.
8 Zone Double-End-of-Line (EOL) No Tamper.
8 Zone Double-End-of-Line (EOL) With open & short circuit Tamper.
Low Zone
Resistor
N/A (Short circuit)
n/c
Alarm Contact
n/c or n/o
8k2
Alarm Contact
n/c or n/o
Tamper
8k2
2k2
4k7
4k7
LED at Addr. P130E
Tamper
2k2
Page 5
Hi Zone
Resistor
N/A
-
8k2
8k2
Type 2 (4 Zones, 2k2 EOL no tamper)
È
LED #1
Zone 1 Short or EOL
LED #2
Zone 2 Short or EOL
LED #3
Zone 3 Short or EOL
LED #4
Zone 4 Short or EOL
LED #5
LED #6
LED #7
LED #8
INPUTS
Tamper
End-of-line
N/A
-
N/A
2k2
n/c
n/o
2k2
Zone Relationship
È
Zone 5 Enabled
Zone 6 Enabled
Zone 7 Enabled
Zone 8 Enabled
Need help?
Do you have a question about the Elite Version 8D and is the answer not in the manual?