Advertisement

Quick Links

KAUGJUHTIMISSÜSTEEMID
TELECONTROL
SYSTEMS
RTU module Telem-AP
User Manual
Martem AS
2016

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RTU Telem-AP and is the answer not in the manual?

Questions and answers

Summary of Contents for Martem RTU Telem-AP

  • Page 1 KAUGJUHTIMISSÜSTEEMID TELECONTROL SYSTEMS RTU module Telem-AP User Manual Martem AS 2016...
  • Page 2: Table Of Contents

    CONTENTS ............ ERROR! BOOKMARK NOT DEFINED. 1. APPLICATION ......................3 2. CONSTRUCTION ....................3 3. FEATURES ......................4 4. TECHNICAL DATA ....................5 5. MODE SWITCHES AND INDICATION LED-S ............6 5.1 DIP switces ..............................6 5.2 Indication LEDs .............................. 6 5.3 Setting an address ............................
  • Page 3: Application

    AS Martem RTU module Telem-AP User Manual Rev. 2 / 2016 1. Application TELEM-AP announciator panel module is used for indication of substation alarms/states provided by RTU or by physical DI-s (3xDI available on the rear panel). 2. Construction • The mechanical design is based on aluminum box suitable for panel- mounting.
  • Page 4: Features

    AS Martem RTU module Telem-AP User Manual Rev. 2 / 2016 3. Features • Time synchronization over IEC60870-5-101 unbalanced • Daisy chain master – slave connection using RS-422 interface • Self diagnostics and supervision simultaneously with data acquisition • 3 physical DI-s that can be linked to indication LED-s (14,15,16) •...
  • Page 5: Technical Data

    AS Martem RTU module Telem-AP User Manual Rev. 2 / 2016 4. Technical Data Number of digital inputs Number of LED-s Additional indication LED-s 1 for „running“ indication, 1 for „alert“ indication Supply voltage 10-72 VDC, <1W Internal circuit voltage for DI signals...
  • Page 6: Mode Switches And Indication Led-S

    AS Martem RTU module Telem-AP User Manual Rev. 2 / 2016 5. Mode Switches and Indication LED-s 5.1 DIP switces Mode of operation, address of the module and the default settings are determined using DIP switches on the board: RST – ON – reset the device DFT –...
  • Page 7: List Of Available Information Objects

    AS Martem RTU module Telem-AP User Manual Rev. 2 / 2016 6. List of available Information Objects AS MARTEM Tel: +372 639 7979 E-mail: martem@martem.eu www.martem.eu...
  • Page 8: Loading Frame Program

    AS Martem RTU module Telem-AP User Manual Rev. 2 / 2016 7. Loading Frame Program 1. Connect power supply to the device 2. DIP switch “Pogram” ON 3. Toggle DIP switch “RST” (ON-OFF) 4. Load programm by executing “AP_SerialDownload_Firmware.bat” 5. Wait until message “Press any key to continue...” appears 6.
  • Page 9: Communication Cables

    AS Martem RTU module Telem-AP User Manual Rev. 2 / 2016 9. Communication Cables Data contcentrator-RTU module connection GW5/RTA RJ 45 RJ 11/4 RTU module RTU module RS-422 Slave-Slave connection RJ 11/6 RJ 11/6 Time sync Time sync RTU module RS-422 Master-Slave connection...
  • Page 10: Panel-Mounting Of Telem-Ap

    AS Martem RTU module Telem-AP User Manual Rev. 2 / 2016 10. Panel-mounting of Telem-AP AS MARTEM Tel: +372 639 7979 E-mail: martem@martem.eu www.martem.eu...

Table of Contents