Jerguson MTII4200 Series Installation, Operation & Maintenance Instructions Manual

Level transmitter

Advertisement

Quick Links

Specialists in Liquid Level Indication
1. INTRODUCTION
The Jerguson Model MTII4200 is a 4-20 mA, loop-powered HART compatible level transmitter intended to be used in
conjunction with the Jerguson Magnicator II magnetic liquid level gage.
The part number designator for the MTII4200 can be found below.
COMM OPTION:
H=4-20mA w/ HART
HOUSING:
A= ALUMINUM w/ WINDOW (STD.)
S= STAINLESS STEEL w/ WINDOW
BA= ALUMINUM w/o WINDOW
TRANSMITTER ORIENTATION:
A= TOP LEFT HAND (STD.)
B= TOP RIGHT HAND
C= BOTTOM RIGHT HAND
D= BOTTOM LEFT HAND
LCD DISPLAY:
M= mA OUTPUT (DEFAULT)
I= INCHES
P= PERCENTAGE
There are two main components that make up the MTII4200. These two components are the electronics housing and the
sensor housing (see Figs. 1 & 2). These two components are assembled at the factory and should not be separated in
the field.
Figure 1. MTII4200-H-A-D-x-x-S-xxx/xxx Straight Bottom Left Hand Assembly
16633 Foltz Industrial Parkway | Strongsville, OH 44149 | Telephone +1 (440) 572-1500 Facsimile: +1 (440)-238-8828
MTII4200 level Transmitter
MTII4200-#-#-#-#-#-#-###/###
FOR V19961-E1= 9.313 (REF.)
FOR V20816-E6 & V21037-T= 8.688 (REF.)
The Clark Reliance Corporation
Email:
sales@clark-reliance.com
Installation, Operation &
Maintenance Instructions
ACTIVE SENSING LENGTH
IN INCHES
MAX SENSING LENGTH
IN INCHES, ON 6 INCH INCREMENTS
MOUNTING STYLE:
S= STRAIGHT (STD.)
H= HIGH TEMP EXTENDED
ALARM SETTING:
L= 3.85 mA (DEFAULT)
H= 22.5 mA
MAX ACTIVE SENSING LENGTH
| Web Site:
www.clark-reliance.com
Section:
Bulletin:
Date:
Supersedes:
(3.500)
DETERMINED BY SE
POSITION AT ASSEMBLY
M500
M500.31
01-26-12
04-22-08

Advertisement

loading

Summary of Contents for Jerguson MTII4200 Series

  • Page 1 Specialists in Liquid Level Indication 1. INTRODUCTION The Jerguson Model MTII4200 is a 4-20 mA, loop-powered HART compatible level transmitter intended to be used in conjunction with the Jerguson Magnicator II magnetic liquid level gage. The part number designator for the MTII4200 can be found below.
  • Page 2: Product Description

    Figure 2. MTII4200-H-A-D-x-x-H-xxx/xxx Bent Bottom Left Hand Angled Assembly (3.500) MAX. ACTIVE SENSING LENGTH DETERMIND BY SE POSITION AT ASSEMBLY 2. PRODUCT DESCRIPTION The MTII4200 liquid level sensor is a multifunctional transmitter with 4-20 mA loop and HART. It provides an analog output of level and the HART digital protocol.
  • Page 3 ENVIRONMENTAL Humidity: 0 to 100% R.H., non-condensing Electronics Operating Temperature: -30 to 160°F (-34 to 71°C) ambient Vessel Pressure: Dependent on float pressure rating, FIELD INSTALLATION Mounting: 3/4 in. NPT fitting or flange mounting Wiring: 2-wire connection, shielded cable or twisted pair to screw terminals through a 3/4 in.
  • Page 4: Electrical Connections And Wiring Procedures

    4. ELECTRICAL CONNECTIONS AND WIRING PROCEDURES Electrical Connections Connect the 24 VDC power supply to the electronics module using the screw terminal block on the electronics module. A typical wiring arrangement is shown in Figure 3. Figure 3 Wiring Diagram For explosion-proof installations, wiring shall be in accordance with the National Electric Code ANSI/NFPA 70, Article 501- Shielded cable, twisted pair of 24 AWG or heavier should be used.
  • Page 5: Maintenance

    6. MAINTENANCE Magnicator II liquid level gauges use magnetostrictive technology and only have one moving part—the float. This technology ensures no scheduled maintenance or re-calibration is required. 6.1 Removal of Electronic Puck The MTII4200 gauge is designed so that the user may remove the electronics module for any reason, including repair or upgrading of the module.
  • Page 6 NOTE: Be sure you have the transmitter loop #1 connected to a load of 250 to 500 Ohms. A unit installed in a control loop is a good example of this loop load. You may also use a load resistor in the range of the above value. 5.
  • Page 7: Alarm Settings

    17.) Press the arrow UP key (far left) so the screen will now display “Set Span?”. 18.) Move the float to the span location. 19.) Press Enter. 20.) The screen will display “Span (corresponding number)”. 21.) Press Enter to reset the (corresponding number) to span and hold for approximately 1-3 seconds. 22.) The screen will display “ACCEPT?”.

This manual is also suitable for:

Mtii4200-h-a-d-x-x-h seriesMtii4200-h-a-d-x-x-s series