Instruction Manual
METROL CO., LTD.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RC Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Metrol RC Series

  • Page 1 RC series Instruction Manual METROL CO., LTD.
  • Page 2 ■ Technical conformity marks Metrol Co., Ltd. Model : RC-K3E Power : 3.6V R 001-A00026 CMIIT ID : 2012DJ3660 Made in Japan AORMETROLRCS001 FCC ID : AORMETROLRCK3E002 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1-this device may not cause harmful interference.
  • Page 3 ....9. Maintenance ....10. Troubleshooting P27−28 www.metrol.co.jp/en...
  • Page 4: Before Using

    A replacement product will be provided on an exchange basis or the malfunctioned product will be repaired free of charge within the warranty period. if the product is or becomes defective and that at the sole discretion of METROL, the defects due to faulty materials or workmanship.
  • Page 5: Other Matters

    Applications in harsh environments ( special environments requiring heat resistance, vacuum and the like ) *Although METROL believes that sound reliability in harsh environments is one of the charac- teristics of our products, there are still cases in which it is difficult to ascertain actual circumstances.
  • Page 6: Glass Window

    ・ Try to keep cable lengths as short as possible at all times. 4 ) Product usage Use of this product in a manner other than that specified by METROL may cause a decrease in the guaranteed performance and functions of the product.
  • Page 7 NOTE www.metrol.co.jp/en...
  • Page 8 Output : Skip signal (PROBE STATUS 2a), PROBE STATUS1, PROBE STATUS 2b, LOW BATTERY, ERROR Response speed Min.1ms From transmitter turns ON until receiver skip signal activates. However, this depends on communicatin status) DC24V±10% Power supply voltage Current consumption  Max.100mA(DC24V ± 10%) www.metrol.co.jp/en...
  • Page 9: Wiring Diagram

    *During the matching procedure, it indicates completion of matching mode (refer to P9) ・ Touch LED : Indicates the signal output of the transmitter.      OFF : Contact OFF ( transmitter signal output OFF )        : Contact ON ( touch probe signal output ON ) www.metrol.co.jp/en...
  • Page 10: Software Specification

    By using ID number, it performs matching with the receiver so that the receiver stores ID. Once ID number is stored in the receiver, it performs communication exclusively and is never affected by any other communication systems. This ID number (transmitter) is stored nonvolatile. Note: Matching is necessary every time transmitter is exchanged. www.metrol.co.jp/en...
  • Page 11 This mode is the initial setting. The receiver stores the ID number of transmitter in order not to be affected by any similar signals. This ID number (transmitter) is stored nonvolatile. Note: Matching is necessary every time the transmitter is exchanged. www.metrol.co.jp/en...
  • Page 12 Note : The matching procedure is performed to record the transmitter ID number in the receiver and prevent interference by other radio signals. Once the matching procedure has been performed, further matching is not required provided the transmitter is not replaced (or repaired). www.metrol.co.jp/en...
  • Page 13 NOTE www.metrol.co.jp/en...