  • Page 1 Compressors META Air Equipment Logbook Assembly, operation and maintenance...
  • Page 2 PLZ / Postal Code /Code Postal /CAP Stadt / City / Cité / Città Seriennummer des METASYS-Geräts / Serial number of the METASYS device: N° série de l'appareil METASYS / Nr. di matricola dell'apparecchiatura METASYS: Seriennummer - Serial number N° série - Nr. di matricola...
  • Page 3 Gerätedokument / equipment LoGbook / Livret d'appareiL / verbaLe d'instaLLazione Vom Techniker auszufüllen: To be filled in by the technician A remplir par le technicien: Da compilare dal tecnico: Druckbedarfsberechnung dentaler Kompressoren/ Compressed air consumption calculation for dental compressors/ Calcul du besoin en air comprimé pour compresseurs dentaires / Calcolo del fabbisogno di aria compressa dei compressori dentali Anzahl Dentaleinheiten/Number of dental units/ Labor/Laboratory/ ...
  • Page 4 Gerätedokument / equipment LoGbook / Livret d'appareiL / verbaLe d'instaLLazione Service und Wartungsarbeiten Service and maintenance Service et maintenance Assistenza e manutenzione Service- und Wartungsarbeiten sind gemäss der Einbau-, Betriebs- und Wartungsanleitung durchzuführen. Service and maintenace must be carried out as per the instructions for the installation, operation and maintenance. Les programmes de service et de maintenance sont à...
  • Page 5 METASYS dopo l‘installazione comporta l‘estinzione del diritto di garanzia. Montaggio ed invio METASYS ne donnera suite aux demandes de garantie que si le produit dell‘aviso del montagio eseguito devono avvenire entro 24 mesi dalla de nettoyage et de désinfection pour l’aspiration GREEN&CLEAN M2...
  • Page 6: Table Of Contents

    Index Key to symbols 1. Index The footnote found on each page defines the user group particular information is aimed at. Page 1. Index 2. Key to symbols 3. General Information 4. Use 5. Scope of delivery 6. Explanation of the type plate 7.
  • Page 7: General Information

    When requested by an authorized engineer, METASYS agrees to make all documents available for the use of technically qualified service personnel. q METASYS accepts no responsibility for damages caused due to external factors, such as wrong installation, improper use of the apparatus or unauthorized technical intervention.
  • Page 8: Use

    Use of the compressors in the vicinity of gases or inflammable liquids is also prohibited. 5. Scope of delivery: All METASYS META Air compressors are shipped in a single package consisting of a pallet plus carton. A booklet containing the installation proof, equipment logbook and manual for installation, operation and maintenance is included in each shipment.
  • Page 9: Technical Data

    Technical data META Air 70 / 150 /250 / 450 7. Technical data META Air 70 Tank capacity 30 l Electric motor power 0,75 kW Delivery rate 78 l/min Dimensions (H x W x D) 40 x 64 x 72 cm...
  • Page 10 Technical data META Air 70 Light / 150 Light / 250 Light / 450 Light META Air 70 Light Tank capacity 30 l Electric motor power 0,75 kW Delivery rate 85 l/min Dimensions (H x W x D) 39 x 57 x 72 cm...
  • Page 11 Technical data META Air 650 / 650 Light META Air 650 Tank capacity 200 l Electric motor power 6,6 kW Delivery rate 660 l/min Dimensions (H x W x D) 85 x 140 x 92 cm Power supply 400 V...
  • Page 12: Description Of Function Of The Compressor

    Periodical maintenance needs to be performed on the double filtration system (0,5 µm, 0,01 µm) before the membrane dryer. Filters cartridges must be replaced once a year. Maintenance kits are available at METASYS. Page Practice personnel / technicians...
  • Page 13: Storage And Transportation Conditions

    Storage and transportation conditions Installation guidelines 10. Storage and transportation conditions: The compressor is dispatched by the manufacturer in a carton on a non-returnable pallet to protect the appliance from damage during transportation. Wherever possible, the original packaging should always be used for transportation. Therefore it is advised to keep the original packaging.
  • Page 14: Instrument Unit

    Instrument unit Electrical connections 12. Instrument unit: See picture The compressor is fitted with an instrument unit as standard: This consists of: q pressure switch q pressure reducer / pressure reducer with condensate separator (Light models only) q safety valve q compressed air supply q manometer q condensate separator (Light models only)
  • Page 15: Preparations Before First Use

    Preparations before first use 14. Preparations before first use Before using the compressor for the first time, it must be ensured that all the fastenings securing the compressor for transportation have been removed. Ensure that the compressed air lines are connected correctly.
  • Page 16: Commissioning And Usage

    Preparations before first use Commissioning and usage 14. Preparations before first use Draining off condensate water During transportation, condensate may form inside the air tank because of temperature fluctuation. Each time a compressor is installed, the condensation water must first be drained off – even in compressors with a membrane dryer.
  • Page 17 The current pressure can be read on the pressure gauge (4). When air pressure required is reached, push the regulating screw downwards in order to block it. META Air Light models META Air models Practice personnel / technicians...
  • Page 18: Wiring Diagrams

    Wiring diagrams 16. Wiring diagrams META Air META Air META Air Light Light META Air META Air META Air META Air Light Light META Air * META Air Light versions only Page Practice personnel / technicians...
  • Page 19 META Air 70 / 70 Light META Air 70 / 70 Light with cover META Air 150 / 150 Light / META Air 250 / 250 Light META Air 150 / 150 Light / META Air 250 / 250 Light...
  • Page 20 Wiring diagrams 16. Wiring diagrams Version with cover META Air META Air Light META Air * META Air Light versions only META Air 450 / 450 Light with cover META Air 650 / 650 Light Page Practice personnel / technicians...
  • Page 21: Service And Maintenance

    Service and maintenance 17. Service and maintenance Service intervals: Switch off the compressor daily Practice personnel at the end of the use Drain off condensate water weekly Practice personnel (versions without dryer or automatic drain) Filter replacement yearly Technician Safety valve check yearly Technician Check tightness of joints...
  • Page 22: Decommissioning And Disposal

    Service and maintenance Decommissioning and disposal 17. Service and maintenance Safety valve check Check if the safety valve functions properly during first use of the compressor. Pull the ring at the top of the safety valve to check if air is vented properly. Warning! Safety valve must not be used to relieve air from the air receiver! Always protect eyes from compressed air using safety glasses!
  • Page 23: Troubleshooting

    3.000 hour service kit 450 + valve block (complete) 50080148 3.000 hour service kit 650 + valve block (complete) 50080149 Filter replacement kit META Air 70 50080150 Filter replacement kit META Air, all other models 50080151 Practice personnel / technicians Practice staff / technicians Page...
  • Page 24 METASYS Medizintechnik GmbH Ahornstraße 19 D-85614 Kirchseeon 1+49/(0)2236 / 37 42 42 5+49/(0)2236 / 37 42 41 France METASYS France S.a.r.l. 9, bd E. Michelet F-69008 Lyon 1+33/(0)4/37 90 22 15 5 +33/(0)4/37 90 22 47 e-mail: info@metasys.fr www.metasys.fr email: info@metasys.com www.metasys.com...