Industrial Cellular IP Modem TD210 Series User Guide Addr.: Unit 704, No. A3 Building, Tel: +86-592-6211770 Software Park, Xiamen, China 361000 Fax: +86-592-6211727 www.bivocom.com sales@bivocom.com...
Product specifications and information in this document are subject to change without any notice, and BIVOCOM reserves the right to improve and change this user guide at any time. Users should take full responsibility for their application of products, and Xiamen Bivocom Technologies Co., Ltd.
About This Guide Thank you for choosing BIVOCOM Industrial Cellular IP Modem TD210 Series. Please thoroughly read this user guide before you configure and install the device. This manual is compatible with below models Model Description TD210-G Industrial GPRS IP Modem...
A computer for receiving data sent from IP Modem through SMS/2G/3G, and sending data to IP Modem through SMS/2G/3G. 1.6 TD210 An industrial IP Modem series manufactured by Bivocom. 2. Introduction 2.1 Overview TR210 Series IP Modem is a type of industrial wireless IP Modem (Also called DTU, Data Transfer Unit), designed to fully meet the needs of industrial standards and industrial users.
3.2 Dimensions There are 3 holes for installation at each side of TD210 (Unit: mm) Addr.: Unit 704, No. A3 Building, Tel: +86-592-6211770 Software Park, Xiamen, China 361000 Fax: +86-592-6211727 www.bivocom.com sales@bivocom.com...
Screw the SMA male cellular antenna to TD210 (SMA female interface), make sure it is screwed tightly to ensure the strength of signal. Addr.: Unit 704, No. A3 Building, Tel: +86-592-6211770 Software Park, Xiamen, China 361000 Fax: +86-592-6211727 www.bivocom.com sales@bivocom.com...
The interface of TD210 is industrial terminal block, we suggest you use 28-16AWG power cable and console cable. Definition of power cable and console cable in this package are as below Addr.: Unit 704, No. A3 Building, Tel: +86-592-6211770 Software Park, Xiamen, China 361000 Fax: +86-592-6211727 www.bivocom.com sales@bivocom.com...
TD210 adopts advanced power technology to improve the stability and adapt to complex external environment. You can use Bivocom standard power adapter(12VDC/500mA), or use DC power ranging at 5-35VDC, please make sure the power supply is stable enough(Ripple shall be less than 300Ma, and Instantaneous voltage shall not larger than 35V), meanwhile, power shall over 4W.
2) BIVOCOM TD210 config tool. The TD210 config tool integrated with configuration, debug and firmware upgrade functions. You can go to BIVOCOM website to download the config tool, like below. http://www.bivocom.com/index.php?m=content&c=index&a=show&catid=12&id=22 Note: The config tool only support Windows OS, IOS is not supported yet.
Page 13
Figure 1 Figure 2 Addr.: Unit 704, No. A3 Building, Tel: +86-592-6211770 Software Park, Xiamen, China 361000 Fax: +86-592-6211727 www.bivocom.com sales@bivocom.com...
Click to save the parameters you’ve configured. 4.2.2 Load Load the parameters of TD210 to config tool and display. 4.2.3 Clear Output Clear log of config tool. Addr.: Unit 704, No. A3 Building, Tel: +86-592-6211770 Software Park, Xiamen, China 361000 Fax: +86-592-6211727 www.bivocom.com sales@bivocom.com...
Save configuration of TD210 in file format, which you can use it recover the config. 4.2.9 Configure via Saved Config File Click , and choose the saved config file, then click to configure TD210. Addr.: Unit 704, No. A3 Building, Tel: +86-592-6211770 Software Park, Xiamen, China 361000 Fax: +86-592-6211727 www.bivocom.com sales@bivocom.com...
The No. of SIM inserted in this device. 4.3.3 Work Mode There are 3 work modes to choose from the drop-down menu, as below Addr.: Unit 704, No. A3 Building, Tel: +86-592-6211770 Software Park, Xiamen, China 361000 Fax: +86-592-6211727 www.bivocom.com sales@bivocom.com...
You can add a phone number in the blank, once the trigger mode is CTRL or MIXD, and TD210 receives the call from this number, it will get online. Addr.: Unit 704, No. A3 Building, Tel: +86-592-6211770 Software Park, Xiamen, China 361000 Fax: +86-592-6211727 www.bivocom.com sales@bivocom.com...
Page 19
TD210 receives the trigger data through RS232/RS485 port, it will get offline. 6) RTC Setting You can set up the system time for your TD210. Addr.: Unit 704, No. A3 Building, Tel: +86-592-6211770 Software Park, Xiamen, China 361000 Fax: +86-592-6211727 www.bivocom.com sales@bivocom.com...
When choose TCPSVR, TD210 acts as a TCP Server. When choose UDPSVR, TD210 acts as a UDP server. Addr.: Unit 704, No. A3 Building, Tel: +86-592-6211770 Software Park, Xiamen, China 361000 Fax: +86-592-6211727 www.bivocom.com sales@bivocom.com...
It can be configured as DNS or IP address. 3) Center DNS Server When you use DNS for center, a DNS server is required to analytic the corresponding IP address. Addr.: Unit 704, No. A3 Building, Tel: +86-592-6211770 Software Park, Xiamen, China 361000 Fax: +86-592-6211727 www.bivocom.com sales@bivocom.com...
Heartbeat time, we suggest you set up 60 seconds for TCP, and 31 seconds for UDP. 4.4.5 Auto Back to Main Server Auto back to main server. Addr.: Unit 704, No. A3 Building, Tel: +86-592-6211770 Software Park, Xiamen, China 361000 Fax: +86-592-6211727 www.bivocom.com sales@bivocom.com...
‘0xfd’ to ‘0xfd’ and ‘0xfe’, and ‘0xfe’ to ‘0xfd’ and ‘0xee’. If choose N, it is transparent transfer. 4.4.9 TCP MTU Set up the maximum number of data transmission for each TCP data packet. Addr.: Unit 704, No. A3 Building, Tel: +86-592-6211770 Software Park, Xiamen, China 361000 Fax: +86-592-6211727 www.bivocom.com sales@bivocom.com...
This helps to maintain connection of Application layer and mobile carrier’s network, to avoid being forced to sleep, and helps to check the stability of connection. Addr.: Unit 704, No. A3 Building, Tel: +86-592-6211770 Software Park, Xiamen, China 361000 Fax: +86-592-6211727 www.bivocom.com sales@bivocom.com...
Format, it will be sent under hexadecimal number 0x00-0xff, which is ideal for industrial automation. 4.5.3 SMS Send Backup Enable Disable Addr.: Unit 704, No. A3 Building, Tel: +86-592-6211770 Software Park, Xiamen, China 361000 Fax: +86-592-6211727 www.bivocom.com sales@bivocom.com...
TD210 act as a MODBUS device. Addr.: Unit 704, No. A3 Building, Tel: +86-592-6211770 Software Park, Xiamen, China 361000 Fax: +86-592-6211727 www.bivocom.com sales@bivocom.com...
When MODBUS is set as RTU mode, digital work mode is set as input or output, TD210 will operate the corresponding terminal port after receiving MODBUS command. 4 Firmware Upgrade 4.4 Please open the Bivocom Config Tool, as below, 1) Configure Serial Port parameters ...
Page 28
4.5 Power on the TD210, then device will start to upgrade the firmware, as below 4.6 After firmware upgrading successfully, it shows ‘download success ok’, as below Addr.: Unit 704, No. A3 Building, Tel: +86-592-6211770 Software Park, Xiamen, China 361000 Fax: +86-592-6211727 www.bivocom.com sales@bivocom.com...
Page 29
4.7 Then use the Config Tool to enter into the configuration status, set up the device to factory setting, and restart to configure the parameters. Addr.: Unit 704, No. A3 Building, Tel: +86-592-6211770 Software Park, Xiamen, China 361000 Fax: +86-592-6211727 www.bivocom.com sales@bivocom.com...
Trigger AT+DOFFPSWD=XX XX: Trigger off data Password Network Word Mode AT+MODE=XX XX: FTCP,HTCP,CTCP, NUDP,CUDP,HUDP Data Center Number AT+SVRCNT=XX XX: number of data center Addr.: Unit 704, No. A3 Building, Tel: +86-592-6211770 Software Park, Xiamen, China 361000 Fax: +86-592-6211727 www.bivocom.com sales@bivocom.com...
Page 31
1, No transfer meaning TCP MTU AT+TCPMTU=XX Data Maximum Transmission Unit Multi Center Reconnect AT+MCONTIME=XX XX: Second(Unit) Interval Connect Retry Times AT+RETR=XX XX: Connect Retry Times Addr.: Unit 704, No. A3 Building, Tel: +86-592-6211770 Software Park, Xiamen, China 361000 Fax: +86-592-6211727 www.bivocom.com sales@bivocom.com...
Page 32
2, Output Digital Work Mode AT+DIOWORKMODE2=XX XX: 0, Disable 1, Input 2, Output Digital Work Mode AT+DIOWORKMODE3=XX XX: 0, Disable 1, Input 2, Output Addr.: Unit 704, No. A3 Building, Tel: +86-592-6211770 Software Park, Xiamen, China 361000 Fax: +86-592-6211727 www.bivocom.com sales@bivocom.com...
Is the RS232/RS485 connected to your computer or laptop and serial port of computer or laptop is working. Check whether the baud rate of computer or laptop is the same as IP Modem. Addr.: Unit 704, No. A3 Building, Tel: +86-592-6211770 Software Park, Xiamen, China 361000 Fax: +86-592-6211727 www.bivocom.com sales@bivocom.com...