  • Page 1 Linear motors PLATINUM™ DDL Technical Description Edition 03/01...
  • Page 2 Previous editions Edition Comment 03/2001 First edition Symbols used in this manual general warning danger to personnel, general instruction from electricity and its effects mechanical hazard See Chapter... (cross-reference) emphasis Þ Technical changes to improve the performance of the equipment may be made without prior notice! Printed in the Federal Republic of Germany 03/01 Mat.No.
  • Page 3: Table Of Contents

    Kollmorgen Seidel Contents 03/01 Contents D r a w i n g P a g e Contents ................3 Safety Instructions .
  • Page 4: Safety Instructions

    Safety Instructions Kollmorgen Seidel 03/01 Safety Instructions The strong magnetic fields which are produced constitute a hazard for persons with implants, such as cardiac pacemakers, that can be influenced by magnetic fields. As a general rule, all persons who may suffer impairment to health through the influence of strong magnetic fields must keep at a safe distance of at least 1 meter from the motor.
  • Page 5 Kollmorgen Seidel Safety Instructions 03/01 Safety Instructions Attach easily visible warning signs (e.g. permanent self-adhesive labels) to the machine: Caution: The linear drives on this machine are fitted with strong permanent magnets. STRONG MAGNETIC FIELDS + HIGH MAGNETIC ATTRACTION FORCES ! The magnet track must never be stored in an unpacked condition.
  • Page 6: Manufacturer's Declaration

    03/01 Manufacturer’s Declaration in accordance with the EC Machine Directive 89/392/EEC, Appendix II B We, the company Kollmorgen Seidel GmbH & Co. KG Wacholderstraße 40-42 40489 Düsseldorf hereby declare that the linear motors of the series PLATINUM™ DDL, Types ICD05-xxx, ICD10-xxx, IC11-xxx, IC22-xxx, IC33-xxx, IC44-xxx...
  • Page 7: General Information

    Kollmorgen Seidel General Information 03/01 General Information About this manual This manual describes the PLATINUM™ DDL series of linear motors. This manual is intended for use by qualified and experienced personnel in the electrical and mechanical engineering industries. The motors are operated within drive systems, together with the SERVOSTAR™ 400/600 servo amplifiers.
  • Page 8: Design Of The Motors

    General Information Kollmorgen Seidel 03/01 Design of the motors PLATINUM™ DDL linear motors (series ICxx and ICDxx) are 3-phase, flat linear motors for sinusoidal commutation, with a patented construction of the laminated winding section. They can be fitted with almost every type of linear measurement system which is suitable for operation with linear motors.
  • Page 9: General Technical Data

    Kollmorgen Seidel General Information 03/01 General technical data Climatic class 3K3 as per EN 50178 Ambient temperature +5 to +40°C at site altitudes up to 1000m a.m.s.l. (under rated conditions) You must consult our applications department for ambient temperatures above 40°C with encapsulated motors.
  • Page 10: Standard Features

    General Information Kollmorgen Seidel 03/01 Standard features I.5.1 Frame size There are no standardized frame sizes for linear motors, but the modular design of the ICxx and ICDxx motors nevertheless makes it possible to find a mechanically suitable motor for just about every drive situation.
  • Page 11: Protective Devices

    Kollmorgen Seidel General Information 03/01 I.5.4 Protective devices The ICD motors are fitted with thermistors. IC motors, on the other hand, have thermostats fitted (floating n.c./break contacts). The resistance value or switching point can be found in the technical data. Thermal monitoring does not provide protection against sudden overloading.
  • Page 12: Technical Data

    General Information Kollmorgen Seidel 03/01 Technical data I.6.1 Terminology Peak force F peak The peak force is used as a design parameter for the acceleration and braking of the load. The motor should not be reqired to generate this force for more than 5 seconds.
  • Page 13: Technical Data Platinum™ Ddl

    Kollmorgen Seidel General Information 03/01 I.6.2 Technical data PLATINUM™ DDL Data Symbol Unit Peak force Fpeak 1130 1250 2500 5625 7500 Peak current Ipeak 15.8 15.8 11.3 11.3 11.0 11.0 22.0 33.1 44.1 Continuous force (at 130°C) Fcont 1198 2718 3617 Continuous current (at 130°C)
  • Page 14: Drawings

    Drawings Kollmorgen Seidel 03/01 - A.4.035.4/03 Drawings II.1 Dimensions PLATINUM™ DDL...
  • Page 15: Ii.2 Wiring Diagram For Hall-Effect Option

    Kollmorgen Seidel Drawings 03/01 - A.4.035.1/01 II.2 Wiring diagram for Hall-effect option PLATINUM™ DDL...
  • Page 16: Appendix

    Appendix Kollmorgen Seidel 03/01 Appendix III.1 Index acceleration, theor. max..12 ambient temperature ... 9 attractive force, magnetic ..12 connections .
  • Page 17 Kollmorgen Seidel Appendix 03/01 This side has been deliberately left blank. PLATINUM™ DDL...
  • Page 18 Ge rmany / Al lemag ne DIGIMATIC ApS M.C.A. s.r.l. Peder Skrams Vej 31A Via f. Turati 21 Kollmorgen Seidel GmbH & Co. KG 5220 Odense SØ 20016 Pero (Mi) Verkaufsniederlassung Nord Tel.: +45 - 70 20 16 70 Tel.: +39(0)02 - 33 91 04 50 Wacholderstr.