Page 1
Show/Hide Bookmarks Manual Global Drive PC system bus adapter 2173 / 2177 Software installation & configuration...
Page 2
E 2003 Lenze Drive Systems GmbH No part of this documentation may be copied or made available to third parties without the explicit written approval of Lenze Drive Systems GmbH. All information given in this online documentation has been carefully selected and tested for compliance with the hardware and software described.
(drive controller, Drive PLC, etc.) and a PC via the system bus (CAN). Two types are available: • The PC system bus adapter 2173 is the classic type. It is connected to the parallel interface (LPT port/printer connection) of the PC or notebook.
In the following text used for Drive PLC Developer Studio Global Drive Control System bus adapter PC system bus adapter 2173 or PC system bus adapter 2177 Universal Serial Bus Layout of the safety information • All safety information have a uniform layout: –...
System bus adapter LED: • PC system bus adapter 2173: The LED lights up as soon as the system bus adapter is connected to the PC and the PC is switched on. If the LED does not light up the system bus adapter does not work properly.
It is automatically installed when the corresponding Lenze tools are installed or can be manually selected for installation. Note! The installation program of the following Lenze tools does not yet include the driver required for PC system bus adapter 2177. A separate driver update has to be installed here: •...
PC system bus adapter 2177. Note! If PC system bus adapter 2173 is used with older versions of the Lenze tools the system bus configuration tool might not yet be available on your PC.
Show/Hide Bookmarks PC system bus adapter 2173 / 2177 Software configuration The system bus adapter has to be configured to allow communication of the Lenze tools via the system bus adapter. Select Programs Lenze Communication System bus configuration tool in the start menu to open the system bus configuration tool: Under ”Hardware Name”...
It is possible to use several PC system bus adapters of type 2177 at the same time. It is, however, not possible to use a PC system bus adapter of type 2177 together with a PC system bus adapter of type 2173. This is why it may happen that certain combinations cannot be activated in the system bus configuration tool.
• Setting range: 1 ... 10 • The standard settings for the LPT1 port and the default baud rate setting for Lenze controllers are preset. • If you want to use an interface different from LPT1 for the system bus adapter or if the settings for I/O address and/or interrupt differ from the standard settings, follow the instructions given in chapter 5.3.1.2 to find out about the actual settings.
Page 12
Show/Hide Bookmarks PC system bus adapter 2173 / 2177 5.3.1.2 Detection of system settings for the LPT interface Windows 9x/Me 1. Select Settings Control panel. 2. Double-click the symbol System. 3. Select the register card Controller manager. 4. Select Ports (COM and LPT) and select the LPT port which is used by the system bus adapter and click Properties.
Show/Hide Bookmarks PC system bus adapter 2173 / 2177 5.3.2 Configuration of PC system bus adapter 2177 The following communication parameters have to be set for PC system bus adapter 2177: Parameter Presetting Meaning Baud rate 500 kbit/s System bus (CAN) baud rate selected in the target system.
Show/Hide Bookmarks PC system bus adapter 2173 / 2177 Diagnostics After configuring the connected system bus adapters a diagnostics can be made to check whether communication is possible with all bus participants. For diagnostics proceed as follows: 1. Select the system bus adapter from the list of system bus adapters in the system bus configuration tool for which you want to make a diagnostics.
Note! Some of the older program versions of the Lenze tools still include possible settings for interrupt and I/O address. When the driver update for PC system bus adapter 2177 is installed these settings will become void.
For the system bus adapter select the entry ”PCAN-USB”. • If Lenze tools are open when pulling off the system bus adapter, they have to be started again if you want to communicate with them. PC system bus adapter EN 1.1...
Show/Hide Bookmarks PC system bus adapter 2173 / 2177 Glossary Abbreviation for Controller Area Network: International bus system standardised as ISO 11898 CANopen A bus system with optimised communication facilities based on CAN technology and the application layer CAL (CAN Application Layer).
Page 18
Show/Hide Bookmarks PC system bus adapter 2173 / 2177 PC system bus adapter EN 1.1...
Need help?
Do you have a question about the 2173 and is the answer not in the manual?