Solid Technologies HERCULES User Manual

5w remote unit

Advertisement

Quick Links

HERCULES   ( 5W   R emote   U nit)  
 
 
 
10,9th   F loor,   S OLiD   S pace220   P angyoyeok-­‐ro,   B undang-­‐gu,   S eongnam-­‐si,   G yeonggi-­‐do,   K orea   3 93-­‐400  
Confidential & Proprietary
User   M anual  
 
   
Tel   :   + 82-­‐31-­‐627-­‐6290     Fax   :   + 82-­‐31-­‐627-­‐6209
 
 
 
 
.  
SOLiD,   I nc
 
1/35
 
 

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HERCULES and is the answer not in the manual?

Questions and answers

Summary of Contents for Solid Technologies HERCULES

  • Page 1 HERCULES   ( 5W   R emote   U nit)   User   M anual                     .   SOLiD,   I nc   10,9th   F loor,   S OLiD   S pace220   P angyoyeok-­‐ro,   B undang-­‐gu,   S eongnam-­‐si,   G yeonggi-­‐do,   K orea   3 93-­‐400  ...
  • Page 2 REVISION   H ISTORY   No.   o f   Version   Issue   D ate   Initials   Details   o f   R evision   C hanges   Pages   V   1 .0   April.   0 7,   2 014    ...
  • Page 3: Table Of Contents

    Safety   &   C ertification   N otice ................ 5 Section2 Introduction ....................8 2.1 Purpose ......................9 2.2 HERCULES ......................10 Section3 Functional   D escription ................11 3.1 General ......................12 3.2 Component   o f   H ERCULES   R emote   U nit .............. 13 3.3 Dimension .......................
  • Page 4 Contents   o f   F igure   Figure   3 .1   –   R emote   U nit   B lock   D iagram ............. 12 Figure   3 .2   –   I nside   o f   R emote   U nit ..............13 Figure  ...
  • Page 5: Safety   &   C Ertification   N Otice

    Section1                                                                 Safety  ...
  • Page 6 “Only   qualified   personnel   should   handle   the   DAS   equipment.   Any   person   involved   in   installation   o r   s ervice   o f   t he   D AS   s hould   u nderstand   a nd   f ollow   t hese   s afety   g uidelines.”        ...
  • Page 7   -­‐   A   r eadyily   a ccessible   d isconnect   d evice   s hall   b e   i ncorporated   e xternal   t o   t he   e quipment.      ...
  • Page 8: Section2

                                                                              Introduction                         Purpose     HERCULES                              ...
  • Page 9: Purpose

      HERCULES   is   in   modular   structure   per   frequency.   To   provide   desired   frequency   in   a   building,   all   you   need  to  do  is  to  insert  a  corresponding  frequency  module  into  each  unit.  As  it  delivers  multiple  signals  ...
  • Page 10: Hercules

    Hercules   t ransports   s ignals   t hat   m ultiple   o perators   a nd   m ultiple   t echnologies   a re   m oved   a t   a   s ame  ...
  • Page 11: Section3

    Section3                                                             Functional  ...
  • Page 12: General

    3.1 General   The   f ollowing   f igure   s hows   t he   b lock   d iagram   o f   H ERCULES   R emote   U nit.       Figure   3 .1   –   R emote   U nit   B lock   D iagram    ...
  • Page 13: Component   O F   H Ercules   R Emote   U Nit

    3.2 Component   o f   H ERCULES   R emote   U nit   The   f ollowing   f igure   s hows   i nternal   c onfiguration   o f   R emoe   U nit   w ith   f ully   R F   e quipped.    ...
  • Page 14 The   f ollowing   t able   d escribes   c omponents   o n   R emote   U nit   Unit   Description   Remote   D rive   U nit   Filter   a nd   a mplify   T X   s ignals   RDU+BPF  ...
  • Page 15: Dimension

    3.3 Dimension     Figure   3 .3   –   R emote   U nit   D imension     ITEM   SPECIFICATION   REMARK   Size(Width,   H eight,   D epth)   320   x   1 165   x   2 60mm   Including  ...
  • Page 16: Section4

    Section4                                                   System  ...
  • Page 17 refer   to   OPTIC   S C/APC   C able   ( 1EA)   -­‐   4.1.5   For   more   M6   S crew   ( 1EA)   No.2   S crew   d river   ( +)   ○  ...
  • Page 18: Remote   U Nit   I Nstallation

    4.1 Remote   U nit   I nstallation   4.1.1 Remote   U nit   E nclosure   i nstallation   Remote  Unit  is  designed  to  be  water-­‐  and  dirt-­‐proof.  The  unit  has  the  structure  of  one-­‐Body  enclosure.   It  satisfies  water-­‐proof  and  quake-­‐proof  standards  equivalent  of  NEMA4(IP66).  Basically  Remote  Unit  is   attached  ...
  • Page 19: Figure   4 .2   –   D Imension   U Sed   T O   I Nstall   R Emote   U Nit   O N   T He   W All

      Figure   4 .2   –   D imension   u sed   t o   i nstall   R EMOTE   U NIT   o n   t he   W ALL          ...
  • Page 20: Figure   4 .3   –   P Rocedures   O F   I Nstallation

    Remote   U nit   W all   M ount   I nstallation     Remote   U nit’s   i nstallation   b racket   i s   a ttached   o n   E nclosure   w hen   i s   d elivered.   I t   d oesn’t   n eed   t o   r emove   bracket  ...
  • Page 21 Remote   U nit   C omponents   Remote   U nit   h as   t he   f ollowing   c omponents:   No.   Unit   Description   Remark   Enclosure   Including   W all   m ounting   b racket   1EA  ...
  • Page 22: How   T O   E Xpand   A Dd   O N   R Ou   A T   T He   R Emote   U Nit

    4.1.2 How   t o   e xpand   A DD   O N   R OU   a t   t he   R emote   U nit                   Remote  Unit  can  expand  ARU  up  to  1.  The  three  item  is  needed  for  connection  between  Remote  Unit  ...
  • Page 23 The   f ollowing   p icture   s hows   t he   c onnection   d iagram   b etween   R emote   U nit   a nd   A DD   O N   R OUs     For  ...
  • Page 24: Remote   U Nit   P Ower   C Abling

    4.1.3 Remote   U nit   P ower   C abling     AC   P ower   Remote   U nit   s upports   o nly   A C120V   o f   i nput   p ower.   P rovided   o utside   p ower   c able   i s   o nly   o ne   t ype.   The  ...
  • Page 25: Remote   U Nit   G Round   C Abling

    4.1.4 Remote   U nit   G round   c abling   The   Grounding   terminal   is   located   at   the   bottom   of   Remote   Unit   enclosure   fixed   by   M6   screw.   Compression  ...
  • Page 26: Figure   4 .8   –   H Ow   T O   I Nstall   G Round   T Erminal

    The   required   part   number   is   JOCT   16-­‐6   supporting   AWG   6.   The   way   to   install   the   grounding   cable   comply   w ith   b elow   p rocedures    ...
  • Page 27: Optical   C Abling

    4.1.5 Optical   C abling   The   Optical   Connector   is   located   at   the   bottom   of   Remote   Unit   enclosure   fixed.   Optical   Cable   can   be   connected  ...
  • Page 28: Figure   4 .11   –   H Ow   T O   I Nstall   O Ptical   C Abling

    The   w ay   t o   i nstall   t he   O ptical   c able   c omply   w ith   b elow   p rocedures   The   p rocedures   a re      ...
  • Page 29: Mounting   O F   M Rdu

    4.1.6 Mounting   o f   M RDU   Remote   U nit   h as   s lots   t o   e nable   u p   t o   s ix   M RDU   m odules   t o   b e   m ounted   i n   i t.   You  ...
  • Page 30: Figure   4 .13   –   H Ow   T O   M Ount   M Rdu

    The   Remote   Unit   holds   a   maximum   of   6   MRDUs.   Guide   brackets   on   the   bottom   of   each   MRDU   slot   simplify   i nstallation   a s   d escribed   b elow.   M RDU   i nstallation   r equires   a   + No.1   t ip   s ize   s crewdriver.    ...
  • Page 31 The   p rocedures   a re     Lift   t he   M RDU   o nto   t he   g uide   b racket   a nd   e nsure   t he   M RDU   i s   l evel   l eft   t o   r ight   Push  ...
  • Page 32: Section5

    Section5                                                                           System  ...
  • Page 33: Physical   S Pecifications

    Physical   S pecifications     Parameter   ROU   Nominal   I mpedance     50   o hm     RF   C onnectors   DIN   F emale   ( 7/16)        ...
  • Page 34: Rf   P Erformance

    RF   p erformance     Parameters   Specification   p er   R DU   Remark   700   AWS-­‐ Category   1900   P CS   850   C ell   AWS-­‐1   700   L TE    ...
  • Page 35: Certification

    Certification     Title   Standards   Remarks   Environmental   Temperature   r ange   -­‐25°C   t o   + 55°C/   -­‐ 13   t o   1 31°F   Ambient   T emperature        ...