TROUBLESHOOTING GUIDE
G.02
PROBLEM
Battery does not work
Battery does not charge
Emergency Descent does not work
If you need further assistance or are in any doubt
please contact ActSafe Systems or your approved
ActSafe distributor.
PROBABLE CAUSE
Battery is flat
BMS shut battery off because of battery
damage or worn out battery
Battery is too cold (below -20°C)
Battery is too hot (above 55°C)
Charger not connected
Charger broken
Battery is too warm (red LED blinks
on Battery)
Battery is too cold (below -10°C)
Battery is worn out
Descent Lever disconnected
REMEDY
Charge the Battery
Exchange Battery
Let the Battery warm up
Let the Battery cool down
Connect Charger to socket
Change charger
Let the Battery cool down
Let the Battery warm up
Replace the Battery
Gently hold the descending rubber
bulge at the centre and re-position
the descender lever in its slot