Care And Maintenance; Troubleshooting Guide; Fcc Statement; Specifications - Beurer GS 226 Instruction Manual

Glass scale
Table of Contents

Advertisement

Available languages

Available languages

5. Care and Maintenance

• Clean the scale with a damp cloth and a mild detergent. Do not immerse the scale in water or rinse it
under running water.
• Store the scale in a cool, dry place when not in use; ensure no objects are placed on the scale during
storage.

6. Troubleshooting Guide

Error
Possible causes
Err
Capacity of 400 lb (180 kg/28 st)
exceeded.
Lo
Low power.
No display
Batteries are depleted or inserted incor-
rectly.
Scale shows
Scale placed on soft surface or movement
unrealistic
took place during measurement.
result

7. FCC Statement

IMPORTANT INFORMATION REQUIRED BY THE FCC
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pur-
suant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harm-
ful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency
energy, and if not installed and used in accordance with the instructions, may cause harmful interference
to radio communications. However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to correct the interference by
one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
NOTICE: Changes or modifications not expressly approved by the party responsible for compliance could
void the user's authority to operate the equipment.

8. Specifications

Battery type
Measuring range
Measurement increments
Transport/storage conditions
Operating conditions
Scale size
Subject to technical modifications.
3 x AAA 1.5 V batteries
11 lb to 400 lb; 5 kg to 180 kg; 0 st: 11 lb to 28 st
0.2 lb; 0.1 kg; 0 st: 1lb
14 °F to 140 °F (-10 °C to 60 °C), 0 % to 85 % relative humidity
41 °F to 104 °F (5 °C to 40 °C), 0 % to 85 % relative humidity
12.6 x 12.6 x 0.8 in (319 x 319 x 21 mm)
5
Remedy
Do not exceed maximum weight.
Replace batteries.
Replace batteries and ensure correct polarity.
• Wait until scale switches off automatically
and repeat measurement.
• Place the scale on hard surface (no carpet-
ing or rugs).
• Stand still during measurement.

Advertisement

Table of Contents
loading

Table of Contents