Wireless TRACcess Interface Retrofit

Installation Instructions

Introduction
This is the Supra Wireless TRACcess Interface Retrofit
Installation Instructions. Read these instructions before
replacing the bezel interface with the wireless interface. If
you do not mount the interface accurately, it will not function
properly. Supra will not be responsible for replacing the
interface if it is damaged or destroyed upon removal.
Installation supplies provided
Drill template
Electronics enclosure with lid
Mounting plate (interior)
Exterior WTI interface plate
Three 9-volt batteries
Four sets of four #8 flathead screws (four different
screw lengths for the mounting plate)
Last battery change sticker
One electrified lockset (no lock core)
Four #8 × 5/16 in. panhead screws and lock
washers (for electronics enclosure)
Six #4 × 1/2 in. flathead screws
Plastic weather cover
CAUTION: The electronics in this package are
electrostatic sensitive devices. Before you install the
unit, discharge or use a grounding belt.
Installation tools required
Drill
Drill bits
File
Phillips screwdriver
Level or punch
Pen or pencil
© 2011 UTC Fire & Security. All rights reserved.
Figure 1. Bezel interface and Wireless interface
Installation
To replace the bezel interface with the wireless interface:
1.
Remove the screws from the electronics enclosure and
remove the electronics enclosure lid.
2.
Disconnect the wiring plugged in to the electronics
enclosure.
3.
Remove the screws that are securing the electronics
enclosure to the bezel interface and remove the
electonics enclosure.
4.
Remove the bezel interface.
5.
Feed the four-wire plug from the exterior WTI interface
plate through the hole in the door, and secure the
interior mounting plate to the exterior mounting plate
(Figure 2). Insert and tighten screws through interior
mounting plate. For 1-1/4 to 1-1/2 in. (32 to 38 mm)
doors, use 3/4 in. (19 mm) screws. For 1-1/2 to 2 in.
(32 to 51 mm), use 1-1/4 in. (38 mm) screws.
Note: If the screw does not fully secure the plates to the
door when tightened, use a shorter screw. Do not
overtighten the long screw.
6.
Thread the four-wire plug from the wireless interface
plate, and the two-wire plug from the lockset through
the thread hole in the electronics enclosure. You will
attach the wires after securing the enclosure.
7.
Using the four #8 × 5/16 in. (16 mm) panhead screws
and lock washers, attach the electronics enclosure to
the interior mounting plate. Position each flat washer
against the inside surface of the electronics enclosure,
then place the lock washer on top of the flat washer,
and secure with the screw.
P/N 10103022P1 • October 2011

Advertisement

loading

Summary of Contents for Supra Wireless TRACcess Interface Retrofit

  • Page 1: Installation Instructions

    Installation Instructions Introduction Figure 1. Bezel interface and Wireless interface This is the Supra Wireless TRACcess Interface Retrofit Installation Instructions. Read these instructions before replacing the bezel interface with the wireless interface. If you do not mount the interface accurately, it will not function properly.
  • Page 2 Do not overtighten the screws, as equipment, or dispose of it at designated collection points. Figure 2. TRAC-Station BT assembly Exterior WTI Interface Plate Lockset 4-wire plug Interior Exterior Electronics Mounting Mounting Enclosure Plate Plate Supra: 800-547-0252 • www.suprasystems.com...