Electrical Connection - TECNOEKA EKC 96/001 Use And Instruction Manual

Table of Contents

Advertisement

Electric Cookers rev. 5 ___________________________________________________EKC 96 (/001-/002) – EKC 96.3
Connection of power cable
Modd. EKC 96 – EKC 96/001 – EKC 96/002 The terminal board is on the rear panel of the
appliance. Open the terminal board cover by obtaining leverage with a screwdriver on the two
side fins. Loosen the cable gripper screw and allow the cable to pass through it. Arrange the
conductors so that the earth conductor is the last to detach from its terminal if the cable goes
into a state of faulty traction.
Connect the phase conductor to the terminal marked with the letter "L", the neutral conductor
to the terminal marked with the letter "N" and the earth conductor to the terminal marked
with the symbol
. Tighten the ring-nut of the cable gripper and close the terminal board
cover. The appliance must be connected to an equipotential system whose efficiency must first
be checked according to current legal regulations. This connection must be made between
different appliances by using the appropriate terminal marked with the symbol
. The
2
equipotential conductor must have a minimum diameter of 2,5mm
The equipotential terminal
is at the rear of the appliance. When the appliance is operating, the supplied voltage must not
deviate from the nominal voltage value of ±10%.
Modd. EKC 96.3 For access to the terminal board, remove the rear panel of the appliance.
Loosen the cable gripper and allow the cable to pass through. Locate the conductors so that the
earth cable is the last to detach from its terminal in the event of reverse pulling. Connect the
phase conductors on the terminals marked "L1" and "L2", the neutral conductor to the
terminal marked "N", and the earth conductor to the terminal marked with symbol
according to the following lay-out:
400V~ 2N
N
L
L
2
1
(this electrical connection lay-out is also available near the power supply terminal board).
Tighten the cable gripper and re-fit the rear panel of the appliance. The appliance must be
connected to an unipotential system whose efficiency must be suitably verified according to
current legal regulations.
This connection must be made between different appliances using the terminal marked with the
2
symbol
. The unipotential conductor must have minimum diameter of 2,5mm
. The
unipotential terminal is located low down at the rear of the appliance.
Make sure that after inserting the power supply cord into the terminal block it does not come
into contact with any of the cooking range's hot parts.
The power cable must comply with the following characteristics:
EKC 96 (/001-/002)
EKC 96.3
Power supply voltage (V~)
230
400 2N
2
2
Power cable diameter
3x1.5 mm
4x2.5 mm
Type of power cable
H07RN-F
Electric cable connection
Type Y
Safety device - The appliance is supplied with a manually resetting thermal breaker to protect
against excessive, dangerous temperatures which could be accidentally generated inside the
oven. If tripped, the device cuts out electrical power to the appliance. To access this device,
remove the panel at the rear of the appliance.
______________________________________________________________________________ page 9