TECNOEKA Srl ______________________________________________________________ use and instruction manual
Residual risks
-
Keep away from the appliance unskilled personel.
With hot oven, open the door carefully in order to avoid violent hot fumes exit, that my
-
cause burning.
The appliance contains electrical parts and must never be washed with a jet of water or
-
steam.
-
To avoid wrong installation, the right gas connection is showed on a label that identifies the
correct gas type to use.
The appliance is electrically connected: before attempting any cleaning operation, cut power
-
to the appliance.
Do not use the door handle to move the appliance (the glass panel may break).
-
-
The removable parts of the cooking top, after the cleaning operation, must be placed
correctly in their housing in order to avoid anomalous and dangerous functioning of the
burners.

4. Gas connection

Connect the appliance to a gas cylinder or mains gas pipe according to the prescriptions of
standards (as per current national installation norms and subsequent amendments). To connect
gas, use an approved rigid metal pipe in copper or stainless-steel (the current national
installation norms and subsequent amendments). The appliance is equipped with threaded GJ
½" pipes for gas inflow. Check if the appliance is designed to operate on the same type of gas
as supplied and if pressure is set for that type of gas. Otherwise, carry out the operations
indicated in paragraph "ADAPTING TO DIFFERENT TYPES OF GAS".
Make sure that supply pressure matches the values indicated in the table "Burner
IMPORTANT -
and nozzle characteristics" (tab.1).
If supply pressures do not match the values in the table, eliminate the cause of this, or inform
the gas company and do not use the appliance. Connection with rigid or flexible metal pipes
must not cause stresses to the appliance pipe ("train").
5. Electric connection
Before performing the electric connection, make sure that:
-
the relief valve and the system can stand the appliance load (see data on the rating
plate);
THE SUPPLY SYSTEM IS EQUIPPED WITH AN APPROPRIATE GROUND CONNECTION IN
-
ACCORDANCE WITH THE REGULATIONS IN FORCE;
the omnipolar system used for the connection can be easily reached with the appliance
-
installed.
In the grid-connected mode, between the appliance and the grid an omnipolar switch must be
inserted, having a minimum opening between contacts of the overvoltage category III (4000 V),
suitable to the load used and in accordance with the regulations in force. The yellow/green
earth cable must not be interrupted by the switch.
If the supply cable is damaged then it must be replaced by the manufacturer or by your
technical support or by a qualified person to avoid any risk.