Installing, Aligning, And Fixing; Connecting The Door; Starting Up And Temperature Regulation - AEG SANTO 2732-4I Operating And Installation Instructions

Integrating fridge-freezer
Table of Contents

Advertisement

GB
Unscrew the central door pivot and fit it on the left
(Fig. 4).
Remount the upper door and screw in the upper
bolt on the LH side (Fig. 5). Unscrew the lower bolt
on the RH side and screw it in on the LH side. Both
doors can now be opened to the left.
Installing, aligning, and fixing
Figs. 6, 7, 8, 9, and 10
Insert the fridge-freezer in the recess of the upright
kitchen unit until the upper limit strip (A) bears
against the unit ceiling or intermediate panel and
the lower door pivot (B) (Fig. 6) closes flush with the
unit floor at the front.
If a gap remains owing to a greater recess height
between the limit strip above and unit ceiling, this
can be closed by insertion of the supplied profile
sealing strip (C) (Fig. 7).
Slide and align a fridge-freezer with doors hinged on
the right until it bears against the LH side (Fig. 8)
and a fridge-freezer with doors hinged on the left
until it bears against the RH side.
Screw in mounting screws (D) above and below.
Insert ventilation grille (E).
Cut supplied the sealing strip (F) (Fig. 9) to length
and press in between the appliance and kitchen
unit side wall.
Seal mounting and hinge holes with supplied plugs
(G) (Fig. 10).

Connecting the door

Figs. 11,12, 13 and 14
Mounting positions for slide pieces (H) (Fig. 11)
should be marked on the appliance doors.
Drillholes of 2.7 mm dia. should be drilled and the
slide pieces screwed on, 2 per door. Open kitchen
unit and appliance doors 90° (Fig. 12). Place guide
pieces (K) on slide pieces (H), prepunch mounting
drillholes 26-30 mm away from the kitchen unit
door edge depending on the furniture sidewall
thickness, and screw on guide pieces (Fig. 13).
Check closing function of doors, and re-adjust slide
pieces (H) and guide pieces (K) as necessary.
Insert cover (O) on lower door pivot (Fig. 14).
16
Starting up and temperature
regulation
Fig. 15
Insert the plug of your fridge-freezer in a plug socket
with protective earth contact wired as prescribed.
The knob for temperature selection is located in the
upper RH part of the refrigerator compartment (A)
(Fig. 15).
The mark to which the knob must be set is located
on top of the thermostat housing (Fig. 15/arrow).
Setting "O" means: Off.
Rotation in direction "1": Lighting on, refriger-
ating unit on, the latter then operating automatically.
Setting "1" means: Highest temperature, warmest
setting.
Setting "6" means: Lowest temperature, coldest
setting.
The internal temperature is strongly affected by the
ambient temperature, loading, and frequent door-
opening. If the setting is changed, the refrigerating
unit of your fridge-freezer does not start immedi-
ately if automatic defrosting is in progress.
When starting your fridge-freezer for the first time,
we recommend selection of setting "6" = lowest
temperature, coldest setting for 3-4 hours.
The necessary refrigerator and freezer compart-
ment temperatures are then rapidly attained. After
3-4 hours, you can set back the knob to a medium
setting between 2 and 4.
Setting when the room
temperature is below 16 °C *)
Fig. 15
In the cold season in unheated rooms, the switch
(B) (Fig. 15) should be switched on. The red pilot
lamp in the switch comes on.
Through engagement of a low heating capacity of
8 W in the refrigerator compartment, it is ensured
that, at a low room temperature, the running time of
the refrigerating unit is prolonged and the storage
temperature of -18°C is attained in the freezer
compartment.
*) Not on all models

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents