Medeco HYBRID eCylinder Installation Procedures Manual

Advertisement

Medeco HYBRID eCylinder
Installation Procedures – Mortise Application

1. What is required:

Hybrid cylinder kit
Hybrid Cylinder (LCU) with proper cam
MCU reader unit
MCU outer cover
MCU spacers
Base plate
Lock Ring
MCU mounting screws
Battery
User key with correct mechanical keyway and cut
Hybrid 125KHz Prox key head
PDA programming device
Programmed from the Hybrid Manager software
Including access rights for the User Key
The functionality to set the MCU clock
Hybrid Manager Software

2. Installation procedure when MCU is programmed at the door

2.1 Remove mechanical cylinder from lockset. (if applicable)
2.2 Verify proper cam on Hybrid cylinder for lockset.
2.3 Rotate cam on back of Hybrid cylinder to home (locked) position – This
removes the cylinder from the shipping (unlocked) position and mechanically
"arms" the Hybrid cylinder. A properly bitted key must now be used to operate
the lock cylinder.
2.4 Install (screw) the Hybrid cylinder into the lockset. Check for operation with
the lockset using the User key to operate the cylinder mechanically. Adjust the
cylinder as necessary for door thickness, cam engagement, etc.
2.5 When cylinder adjustments are complete, tighten set screw in lockset to
secure cylinder in place.
1 of 6
12/04/07
Revision 1.0

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HYBRID eCylinder and is the answer not in the manual?

Questions and answers

Summary of Contents for Medeco HYBRID eCylinder

  • Page 1 12/04/07 Revision 1.0 Medeco HYBRID eCylinder Installation Procedures – Mortise Application 1. What is required: Hybrid cylinder kit Hybrid Cylinder (LCU) with proper cam MCU reader unit MCU outer cover MCU spacers Base plate Lock Ring MCU mounting screws Battery...
  • Page 2 12/04/07 Revision 1.0 2.6 Install base plate and lock ring to secure lock cylinder to door. Install spacers as required for thin door applications. 2.7 Place cylinder in locked position and remove the User key. User key is no longer needed until Hybrid unit is programmed. 2.8 Ensure the battery is removed from the MCU unit.
  • Page 3 12/04/07 Revision 1.0 MCU registers with the LCU MCU establishes authorization with the LCU MCU turns on the IR communications port. The MCU will flash the LED red when the IR communications session times out. 2.14 Program the MCU with the PDA – PDA should be loaded with key list (including User key used for installation) 2.15 Present the PDA to the MCU –...
  • Page 4 12/04/07 Revision 1.0 3.2 Install the MCU outer cover The tamper switch will be reset The MCU will start to search (ping) for a credential At this point: MCU is still in tamper mode MCU has no master credential identified and stored MCU and LCU are not registered to each other –...
  • Page 5 12/04/07 Revision 1.0 The MCU will flash LED green at the completion of the communications session. (The MCU will flash the LED red if the IR communications session times out prior to completing the communications session.) Note: The MCU battery should be removed until the unit is installed at the door. 4.
  • Page 6 12/04/07 Revision 1.0 The LCU will power up and “arm” the electronic blocking mechanism (mechanical key alone will no longer operate lock) 4.12 Install the MCU outer cover The tamper switch will be reset The MCU will start to search (ping) for a credential At this point: MCU is still in tamper mode MCU has a master credential previously identified and stored...

This manual is also suitable for:

Hybrid e-cylinder

Table of Contents