Care Touch Platinum Blood Pressure Monitor User Manual

Care Touch Platinum Blood Pressure Monitor User Manual

Fully automatic wrist
Hide thumbs Also See for Platinum Blood Pressure Monitor:

Advertisement

Manufactured in China for Future Diagnostics LLC
Brooklyn N.Y. 11220
Package Design © 2016
CareTouch is a Trademark of Future Diagnostics LLC

Advertisement

loading

  Also See for Care Touch Platinum Blood Pressure Monitor

  Related Manuals for Care Touch Platinum Blood Pressure Monitor

No related manuals

  Summary of Contents for Care Touch Platinum Blood Pressure Monitor

  • Page 1 Manufactured in China for Future Diagnostics LLC Brooklyn N.Y. 11220 Package Design © 2016 CareTouch is a Trademark of Future Diagnostics LLC...
  • Page 2: Table Of Contents

    CATALOGUE CATALOGUE INTRODUCTION ............... 2 General Description Safety Information Indications for use Measurement principle LCD Display Signal Monitor Components BEFORE YOU START ............5 Installing and Replacing the Batteries Setting Date, Time and Measurement Unit MEASUREMENT ............... 9 Tie the Cuff Start the Measurement DATA MANAGEMENT ............
  • Page 3: Introduction

    CAUTION General Description This device is intended for adult use only. Thank you for selecting CARE TOUCH This device is intended for no-invasive measuring and monitoring of arterial blood Fully Automatic Wrist Blood Pressure Monitor (PSW01). pressure. It is not intended for use on extremities other than the wrist or for functions The monitor features blood pressure measurement, pulse rate measurement and other than obtaining a blood pressure measurement.
  • Page 4: Lcd Display Signal

    INTRODUCTION INTRODUCTION LCD Display Signal Monitor Components SYSTOLIC LCD DISPLAY MEM BUTTON DIASTOLIC GRADE SET BUTTON TIME PULSE RATE SYMBOL DESCRIPTION EXPLANATION START/STOP BUTTON Systolic High pressure result blood pressure Component List: Diastolic 1. PCBA; Low pressure result blood pressure 2.
  • Page 5: Before You Start

    BEFORE YOU START BEFORE YOU START Setting Date, Time and Measurement Unit Installing and Replacing the Batteries It is important to set the clock before using your blood pressure • .Open the battery cover. monitor, so that a time stamp can be assigned to each record that is •...
  • Page 6: Measurement

    BEFORE YOU START MEASUREMENT Tie the Cuff 4.Repeat steps 2 and 3 to confirm [MONTH] and [DAY]. .Remove all accessories (watch,bracelet,etc) from your wrist.If your physician has diagnosed you with poor circulation in your wrist,use the other one. 2. Roll or push up your sleeve to expose the skin. 3.
  • Page 7: Start The Measurement

    MEASUREMENT DATA MANAGEMENT Recall the Records Start the Measurement When the monitor is off, press “MEM” button to 1.When the monitor is off, show the latest measurement press the START/STOP to turn on record. the monitor, and it will finish the whole measurement.
  • Page 8: Delete The Records

    DATA MANAGEMENT INFORMATION FOR USER Tips for Measurement Delete the Records If you did not get the correct measurement, you can delete all Measurements may be inaccurate if taken in the following results by following steps below. circumstances. In the memory mode, hold pressing “MEM”...
  • Page 9: Maintenance

    Please note that the device does not replace a cardiac • Please report to CARE TOUCH if any unexpected operation or events occur. examination, but serves to detect pulse irregularities at an early stage.
  • Page 10: Why Does My Blood Pressure Fluctuate Throughout The Day

    ABOUT BLOOD PRESSURE TROUBLESHOOTING Why does my blood pressure This section includes a list of error messages and frequently asked questions for problems you may encounter with your wrist fluctuate throughout the blood pressure monitor. If the products not operating as you day? think it should, check here before arranging for servicing.
  • Page 11: Specifications

    CONTACT INFORMATION SPECIFICATIONS Contact Information Battery powered mode: Power supply 800.758.3830 2*AAA batteries (3V DC) Manufactured in China for Future Diagnostics LLC Display mode Digital LCD V.A.35mm×41mm Brooklyn N.Y. 11220 Package Design © 2016 Measurement mode Oscillographic testing mode CareTouch is a Trademark of Future Diagnostics LLC Pressure: 0kPa-40kPa (0mmHg-300mmHg) Measurement range Complied Standards List...
  • Page 12: Emc Guidance

    EMC GUIDANCE Table 2 Guidance and MANUFACTURER’s declaration – electromagnetic EMC GUIDANCE IMMUNITY – for all ME EQUIPMENT and ME SYSTEMS 1) * This product needs special precautions regarding EMC and needs to be Guidance and manufacturer’s declaration – electromagnetic immunity installed and put into service according to the EMC information provided, and The device is intended for use in the electromagnetic environment specified below.
  • Page 13 Table 6 Recommended separation distances between portable and mobile Table 4 Guidance and MANUFACTURER’s declaration – electromagnetic IMMUNITY – RF communications equipment and the ME EQUIPMENT or ME SYSTEM – for ME EQUIPMENT and ME SYSTEMS that are not LIFE-SUPPORTING for ME EQUIPMENT and ME SYSTEMS that are not LIFE-SUPPORTING Guidance and manufacturer’s declaration –...