Visit our website at www.HDWELD.co.kr www.hyundaiwelding.com HEAD OFFICE : ILSONG BLDG. 16th fl.157-37, SAMSUNG-DONG, KANGNAM-KU, SEOUL, KOREA TEL : (+82-2)6230-6062 5 FAX: (+82-2)522-2030 ~ FACTORY : 9-2, SAEUM-DONG, ICHEON-SI, GYEONGGI-DO, KOREA TEL : (+82-31)636-3100 FAX: (+82-31)636-3957...
Page 11
Φ Use this welding power source at or under the rated duty cycle Exceeding the rated duty cycle limitation may result in damage to the welding machine. • The duty cycle is the percentage of a ten minute period that a welding power source can be operated at a given output without causing overheating and damaging the unit.
Page 15
2. Welding cables, the coverings of which are not capable of withstanding a conductor temperature of 85 , will be damaged if the coupling devices are used at the rating given above at an ambient air temperature of 40 .
Page 16
Connection observes and handle wiring in below. 1) Connect the power cable for base metal between the "Base metal (-)" terminal and the base metal. 2) Attach the power cable for wire feeder to the "Wire feeder (+)" output terminal. 3) Insert the control cable for wire feeder into the socket for wire feeder.
Page 19
• Connecting Input Power must meet all National and Local Codes - have only qualified persons make this connecting. • Before connecting input power, See rating label on unit and check input voltage available at site.
Page 21
TORCH SW DELAY 5s MAGNETIC SW POST GAS(0.2s) SOLENOID VALVE NO LOAD VOLTAGE DELAY VOLTAGE OUTPUT VOLTAGE (0.4s) SLOW DOWN WIRE FEEDER WELDING CURRENT WELDING CRATER STOPS AFTER FAN COOLING DELAY 3 min DETECT WELDING CURRENT 0.2s TORCH SW DELAY 5s MAGNETIC SW POST GAS(0.2s) SOLENOID VALVE...
Page 26
TROUBLE CAUSE MEASUREMENT WHEN POWER 'ON', 1. POWER DOES NOT 1. CHECK INPUT VOLTAGE ON POWER LAMP, SUPPLY. MAGNETIC CONTACTOR. COOLING FAN DOES (3PHASE, 220V,380V,440V,415V) NOT WORK 2. POWER S/W IS BAD 2. CHECK POWER S/W, IF NOT GOOD, REPLACE IT WITH GOOD. 3.
Page 27
TROUBLE CAUSE MEASUREMENT WHEN GAS S/W OR 1. NO GAS IN BOMBE 1. FILL UP GAS TORCH S/W IS 'ON', 2. VALVE OPENNING IS NOT 2. OPEN VALVE ENOUGH PRESSURE ENOUGH. WEAK. 3. GAS LEAKS. 3. REPAIR GAS PATHWAY. 4. GAS PATHWAY IS BLOCKED 4.
Page 28
TROUBLE CAUSE MEASUREMENT 6. W/F MOTOR IS BAD 6. REPLACE MOTOR INCAPABLE OF 1. VR(VARIABLE RESISTOR) 1. REPLACE VR CONTROLLING WIRE VOLUNE ON W/F IS BAD FEEDING SPEED. 2. CONTROL CABLE IS BAD 2. REPAIR CABLE 3. PCB IS BAD 3.
Page 29
TROUBLE CAUSE MEASUREMENT HEATING REGULATOR 1. AUX.TR IS BAD 1. VOLTAGE BETWEEN NO.81 & VOLTAGE IS NOT 82 OF AUX.TR IS NOT DETECTED DETECTED. 110VAC, REPLACE AUX.TR 2. FUSE(F3) IS BROKEN 2. REPLACE FUSE(250V, 3A) BLOW HOLE OCCURS. 1. GAS IS NOT OUT 1.