  • Page 1 FT500 Batch Flow Processor Instructions PROUDLY MADE IN THE 9001:2008...
  • Page 3: Table Of Contents

    Settings and Operation FT520 Batch Controller ..............................Page 6 FT520-84 Filter Regeneration ..........................Page 7 FT520-86 Flowrate Alarm ............................Page 8 FT522 Usage Monitor ..............................Page 9 Repair/Troubleshooting Repair ....................................Page 10 Troubleshooting ................................Page 10 Warranty Seametrics Limited Warranty ..........................Page 11 Seametrics • 253.872.0284 Page 3 seametrics.com...
  • Page 4: General Information

    Sensor Input 1–1000 Hz, ESD protected, interfaces to current sinking sensor output Environmental NEMA 4X, IP66 Setup Memory Non-volatile EEPROM, auto-backup *Specifications subject to change. Please consult our web site for current data (seametrics.com) Seametrics • 253.872.0284 Page 4 seametrics.com...
  • Page 5: Installation

    0-5 V or • Main power fuse 0-10 V or • 250mA 4-20mA 4-20 mA Passive Jumpers Line *Consult Seametrics before Analog Switch* Neutral AC Power changing from factory preset Ground Analog Header 110 Vac 220 Vac Jumpers Jumper Seametrics • 253.872.0284 Page 5 seametrics.com...
  • Page 6: Settings And Operation

    The K-factor is simply the number of pulses which the flow meter or flow sensor puts out per gallon of liquid. It is marked TX Flow Sensor on the Model/Serial tag of Seametrics flow meters and flow Low- Flow Valve sensor fittings.
  • Page 7: Ft520-84 Filter Regeneration

    - Clear Total This function resets the accumulated total back to zero. It is On the input side, this model can be used with Seametrics unrelated to the regeneration function, and can be ignored flow sensors and meters, as well as with water meters unless it is needed.
  • Page 8: Ft520-86 Flowrate Alarm

    The K-factor is simply the number of pulses which the flow meter or flow sensor puts out per gallon of liquid. It is marked on the Model/Serial tag of Seametrics flow meters and flow sensor fittings. On adjustable depth flow sensors, the K-factor must be taken from the chart in the flow sensor instructions, based on pipe size.
  • Page 9: Ft522 Usage Monitor

    The FT522 is a flowmeter monitor with added output and This function resets the accumulated total back to zero in alarm features. It is designed for use with Seametrics flow the rate/total configuration. It does not affect the data in the meters and sensors, as well as other units which have a elapsed time/flow configuration.
  • Page 10: Repair/Troubleshooting

    Check for continuity with multimeter Display reads flow rate when Long flow sensor wire, running Reroute wire or switch to shielded wire there is none parallel to power lines Flow sensor malfunction See flow sensor manual to check Seametrics • 253.872.0284 Page 10 seametrics.com...
  • Page 11: Seametrics Limited Warranty

    CONSEQUENTIAL DAMAGE CAUSED BY THE USE OR MISUSE OF, OR INABILITY TO USE THE PRODUCTS, REGARDLESS OF THE LEGAL THEORY ON WHICH THE CLAIM IS BASED, AND EVEN IF SEAMETRICS HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. IN NO EVENT SHALL RECOVERY OF ANY KIND AGAINST SEAMETRICS BE GREATER IN AMOUNT THAN THE PURCHASE PRICE OF THE PRODUCT SOLD BY SEAMETRICS AND CAUSING THE ALLEGED DAMAGE.
  • Page 12 Seametrics • 19026 72nd Avenue South • Kent, Washington 98032 • USA LT-65200029r1.1-20170503 (P) 253.872.0284 • (F) 253.872.0285 • 1.800.975.8153 • seametrics.com 5/3/2017...