Memory-Layout - Atlas Copco Air Contact Hardware Manual

Gsm-gprs modem
Table of Contents

Advertisement

5.2 Memory-Layout

The Siemens microcontroller C164CI is configured so that up to 1MByte external, linear memory is
addressable. Code and data are accessed in the same address space. The C164CI has internal
2 kByte RAM
Special Function Register area
The internal and the external memory area are mapped into common address space. For more
information refer to the Siemens data book. The table below shows the external memory configuration.
The memory is 8-Bit oriented.
External 8-Bit Memory Organisation
Address
FFFFFh
FF000h
FEFFFh
E0000h
DFFFFh
80000h
7FFFFh
40000h
3FFFFh
00000h
Default configuration for the memory is 512kByte Flash and 124kByte SRAM, optionally the
1024kByte flash could be also mounted.
MSB
Memory
Reserved
SRAM AREA
FLASH AREA
LSB
possible device sizes
124k x 8
512k x 8
256k x 8
Air Contact Hardware Manual
not
accesable
896k x 8
12